OSHA has inspected Bobby Lee and Co Inc. 8 times in Texas since 1984.

The latest one began on Jul 10, 2020 as a planned inspection, in Argyle.

Those inspections ended with 22 citation items: 22 serious.

Penalties were first proposed at $17,032 and now stand at $14,325, 16% lower after settlements or reviews.

Scaffolds, general requirements comes up most often in these citations: 17 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Bobby Lee and Co Inc. averages $1,735 (1 cited inspection).

1 inspection on this page followed a fatal incident.

Bobby Lee and Co Inc.: OSHA citation items per year, 1984 to 2020
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

399employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Bobby Lee and Co Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344827985 OPENED JUL 10, 2020Closed

Planned · Partial · Safety · 5 employees at the site · Closed Aug 19, 2020

151 Fm 407e, Argyle, TX 76226 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$2,892$1,735Aug 3, 2020Final

Inspection 308650423 OPENED FEB 23, 2006Closed

Unprogrammed related · Partial · Safety · 1 employee at the site · Closed Feb 24, 2006

735 Plaza Boulevard, Coppell, TX 75019 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 307489765 OPENED APR 6, 2005Closed

Planned · Partial · Safety · 4 employees at the site · Closed Sep 12, 2005

7902 Walnut Hill And Fair Oaks, Dallas, TX 75231 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 307488726 OPENED FEB 3, 2005Closed

Planned · Partial · Safety · 2 employees at the site · Closed Sep 16, 2005

1309 Beltline Road, Desoto, TX 75115 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 2
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$1,500$750Mar 17, 2005Final

Inspection 304274400 OPENED DEC 5, 2002Closed

Planned · Partial · Safety · 28 employees at the site · Closed Jan 17, 2003

3000 Fort Worth Hwy., Hudson Oaks, TX 76087 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 122186307 OPENED NOV 19, 1999Closed

Accident · Partial · Safety · 30 employees at the site · Closed Jan 19, 2001

3401 Lee Parkway, Dallas, TX 75201 · OSHA's record · Phone and website on Google Maps

Incident on Nov 18, 1999 (fatal): Employee killed in fall from scaffold

Employee #1, a plasterer, was working on a mast-climbing scaffold. He was at the exterior of the 17th floor when a section of the scaffold decking slipped off t he extension arms of the working platform. Employee #1 fell 14 stories to the ro of of the third-floor parking garage, and was killed. The scaffold decking was i nadequately secured and although Employee #1 was wearing a safety harness, he wa s not tied off. The fall protection system being used by subcontractors on site consisted of a rope strung across the front frame section of each mast-climbing scaffold and hand-tied to the frame. Employees were then tied off to this rope.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(3)(ii) · Scaffolds, general requirements
Serious$4,200$2,100Apr 18, 2000Closed
Citation 1, item 2
29 CFR 1926.451(b)(4) · Scaffolds, general requirements
Serious$4,200$3,000Apr 18, 2000Closed
Citation 1, item 3a
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$4,200$4,200Apr 18, 2000Closed
Citation 1, item 3b
29 CFR 1926.502(d)(21) · Fall protection systems
Serious$0$0Apr 18, 2000Closed

Inspection 300519204 OPENED SEP 1, 1998Closed

Unprogrammed related · Partial · Safety · 30 employees at the site · Closed Oct 15, 1998

4921 Bryant Irving Rd, Fort Worth, TX 76132 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 13a
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$0$2,500Sep 9, 1998Closed
Citation 1, item 13b
29 CFR 1926.451(b)(2) · Scaffolds, general requirements
Serious$0$0Sep 9, 1998Closed
Citation 1, item 13c
29 CFR 1926.451(b)(4) · Scaffolds, general requirements
Serious$0$0Sep 9, 1998Closed
Citation 1, item 13d
29 CFR 1926.451(b)(7) · Scaffolds, general requirements
Serious$0$0Sep 9, 1998Closed
Citation 1, item 13e
29 CFR 1926.451(b)(8) · Scaffolds, general requirements
Serious$0$0Sep 9, 1998Closed
Citation 1, item 13f
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$0$0Sep 9, 1998Closed
Citation 1, item 13g
29 CFR 1926.451(c)(3) · Scaffolds, general requirements
Serious$0$0Sep 9, 1998Closed
Citation 1, item 13h
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$0$0Sep 9, 1998Closed
Citation 1, item 13i
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$0$0Sep 9, 1998Closed
Citation 1, item 13j
29 CFR 1926.451(f)(4) · Scaffolds, general requirements
Serious$0$0Sep 9, 1998Closed
Citation 1, item 13k
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$0$0Sep 9, 1998Closed
Citation 1, item 13l
29 CFR 1926.451(h)(1) · Scaffolds, general requirements
Serious$0$0Sep 9, 1998Closed
Citation 1, item 13m
29 CFR 1926.452(c)(2) · Rules for each type of scaffold
Serious$0$0Sep 9, 1998Closed
Citation 1, item 13n
29 CFR 1926.454(a) · Scaffold training
Serious$0$0Sep 9, 1998Closed
Citation 1, item 13o
29 CFR 1926.454(b) · Scaffold training
Serious$0$0Sep 9, 1998Closed

Inspection 305193 OPENED FEB 14, 1984Closed

Planned · Complete · Safety · 8 employees at the site · Closed Mar 21, 1984

6100 Woodlake Pkwy, San Antonio, TX 78244 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(d)(10) · Scaffolds, general requirements
Serious$40$40Feb 27, 1984Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)

(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:

29 CFR 1926.451(b)(2)

(2) Except as provided in paragraphs (b)(2)(i) and (b)(2)(ii) of this section, each scaffold platform and walkway shall be at least 18 inches (46 cm) wide.

29 CFR 1926.451(b)(3)(ii)

(ii) The maximum distance from the face for plastering and lathing operations shall be 18 inches (46 cm).

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.454 · Scaffold training

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.502 · Fall protection systems

Other drywall and insulation contractors employers in Texas