OSHA SearchOSHA records by employer

Bolton Steel Erectors: OSHA inspections and violations

Austin, Texas · Structural Steel and Precast Concrete Contractors · NAICS 238120

5inspections
16citation items
$31,400current penalties
Jan 26, 2021last inspection

Since 2008, OSHA inspectors have visited Bolton Steel Erectors in Texas 5 times.

The most recent inspection opened on Jan 26, 2021 as a planned inspection, in Midland.

In all, OSHA issued 16 citation items: 10 serious, 4 repeat and 2 other-than-serious.

The proposed penalties came to $44,924; today they stand at $31,400, 30% less.

The rule cited most here is 1926.501 (fall protection in construction), 3 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Bolton Steel Erectors averages $5,000 across 1 cited inspection.

Bolton Steel Erectors: OSHA citation items per year, 2008 to 2021
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

399employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Bolton Steel Erectors and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345125264 OPENED JAN 26, 2021Closed

Planned · Partial · Safety · 2 employees at the site · Closed Feb 11, 2022

6600 Briarwood, Midland, TX 79701 · All Other Specialty Trade Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(10) · Fall protection in construction
Other-than-serious$9,557$5,000May 4, 2021Final
Citation 2, item 1
29 CFR 1926.1060(a) · Ladder and stairway training
Other-than-serious$767$0May 4, 2021Final

Inspection 338785637 OPENED FEB 8, 2013Closed

Planned · Partial · Safety · 12 employees at the site · Closed Mar 13, 2014

224 Early Blvd, Early, TX 76802 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(a)(6) · Scaffolds, general requirements
Serious$2,800$2,800Mar 13, 2013Final
Citation 1, item 2b
29 CFR 1926.451(c)(2)(iv) · Scaffolds, general requirements
Serious$2,800$0Mar 13, 2013Final
Citation 2, item 1a
29 CFR 1926.760(a)(1) · Fall protection
Repeat$9,800$9,800Mar 13, 2013Final
Citation 2, item 2b
29 CFR 1926.761(b) · Training
Repeat$4,200$0Mar 13, 2013Final

Inspection 314274598 OPENED JUL 22, 2010Closed

Planned · Partial · Safety · 50 employees at the site · Closed Sep 23, 2010

3208 4th St, Brownwood, TX 76804 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.760(a)(1) · Fall protection
Serious$3,000$3,000Aug 24, 2010Closed
Citation 1, item 2
29 CFR 1926.761(b) · Training
Serious$3,000$3,000Aug 24, 2010Closed

Inspection 312848054 OPENED FEB 18, 2009Closed

Planned · Complete · Safety · 19 employees at the site · Closed Apr 22, 2009

2301 Menard Hwy., Brady, TX 76825 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
OSH Act Section 5(a)(1) · General Duty Clause
Serious$2,000$2,000Apr 2, 2009Closed
Citation 1, item 2
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$800$800Apr 2, 2009Closed
Citation 2, item 1
29 CFR 1926.100(a) · Hard hats in construction
Repeat$1,600$1,600Apr 2, 2009Closed
Citation 2, item 2
29 CFR 1926.501(b)(1) · Fall protection in construction
Repeat$1,600$1,600Apr 2, 2009Closed

Inspection 311316921 OPENED OCT 29, 2008Closed

Planned · Partial · Safety · 19 employees at the site · Closed Nov 19, 2008

6811 Austin Centre Blvd, Austin, TX 78731 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.100(a) · Hard hats in construction
Serious$750$450Oct 30, 2008Closed
Citation 1, item 2 Serious$750$450Oct 30, 2008Closed
Citation 1, item 3
29 CFR 1926.453(b)(2)(v) · Aerial lifts
Serious$750$450Oct 30, 2008Closed
Citation 1, item 4
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$750$450Oct 30, 2008Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.100 · Hard hats in construction

29 CFR 1926.100(a)

(a) Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets.

29 CFR 1926.1060 · Ladder and stairway training

29 CFR 1926.1060(a)

(a) The employer shall provide a training program for each employee using ladders and stairways, as necessary. The program shall enable each employee to recognize hazards related to ladders and stairways, and shall train each employee in the procedures to be followed to minimize these hazards.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(a)(6)

(6) Scaffolds shall be designed by a qualified person and shall be constructed and loaded in accordance with that design. Non-mandatory appendix A to this subpart contains examples of criteria that will enable an employer to comply with paragraph (a) of this section.

29 CFR 1926.453 · Aerial lifts

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.760 · Fall protection

29 CFR 1926.761 · Training

OSH Act Section 5 · General Duty Clause

Other structural steel and precast concrete contractors employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.