Bonnell Industries, Inc.: OSHA inspections and violations
Dixon, Illinois · Heavy Duty Truck Manufacturing · NAICS 336120
4inspections
11citation items
$21,250current penalties
Jan 21, 2020last inspection
Since 1982, OSHA inspectors have visited Bonnell Industries, Inc. in Illinois 4 times.
The most recent inspection opened on Jan 21, 2020 after a complaint, in Dixon.
In all, OSHA issued 11 citation items: 8 serious and 3 other-than-serious.
The proposed penalties came to $52,913; today they stand at $21,250, 60% less.
The rule cited most here is 1910.179 (overhead and gantry cranes), 3 times.
Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Bonnell Industries, Inc. averages $10,625 across 2 cited inspections.
Bonnell Industries, Inc. also files yearly injury logs with OSHA, summarized below.
Citation items per year, by inspection date.
Illinois · latest 90 days of OSHA records
416employers cited
Get notified the morning OSHA posts each new citation in Illinois: the employer, the site address, the rules broken and the penalty.
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2025, the Dixon site logged 17 recordable injuries or illnesses among about 98 workers: 16.7 per 100 full-time workers, against a median of 5.2 for its industry. Those cases cost 129 days away from work.
Site and year
Workers
Cases
Days-away cases
Rate
Industry median
Bonnell Industries Inc
Dixon · 2025
98
17
2
16.7
5.2
Bonnell Industries Inc.
Dixon · 2021
84
8
2
8.6
2.3
Included with any plan: 4 more yearly logs from these sites, back to 2017, with each site's average rate over its latest three years. Already a subscriber? Sign in.
(i) The spraying operations except electrostatic spraying operations shall be so designed, installed and maintained that the average air velocity over the open face of the booth (or booth cross section during spraying operations) shall be not less than 100 linear feet per minute. Electrostatic spraying operations may be conducted with an air velocity over the open face of the booth of not less than 60 linear feet per minute, or more, depending on the volume of the finishing material being applied and its flammability and explosion characteristics. Visible gauges or audible alarm or pressure activated devices shall be installed to indicate or insure that the required air velocity is maintained. Filter rolls shall be inspected to insure proper replacement of filter media.
29 CFR 1910.107(g)(2)
(2) Cleaning. All spraying areas shall be kept as free from the accumulation of deposits of combustible residues as practical, with cleaning conducted daily if necessary. Scrapers, spuds, or other such tools used for cleaning purposes shall be of nonsparking material.
(1) General. The employer shall provide a medical evaluation to determine the employee's ability to use a respirator, before the employee is fit tested or required to use the respirator in the workplace. The employer may discontinue an employee's medical evaluations when the employee is no longer required to use a respirator.
Alert subscribers get notified of each newly cited employer in Illinois the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.