Inspection 348930025 OPENED MAY 11, 2026Closed
1958 Unsinkable Street, Flagler Beach, FL 32136 · Boat Building · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Since 2000, OSHA inspectors have visited Boston Whaler, Inc. in Florida 11 times.
The most recent inspection opened on May 11, 2026 as a planned inspection, in Flagler Beach.
In all, OSHA issued 26 citation items: 9 serious and 17 other-than-serious.
The proposed penalties came to $47,375; today they stand at $36,628, 23% less.
The rule cited most here is 1910.95 (noise), 3 times.
Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Boston Whaler, Inc. averages $7,182 across 3 cited inspections.
Boston Whaler, Inc. also files yearly injury logs with OSHA, summarized below.
It reported 2 severe injuries to OSHA since 2015.
Florida · latest 90 days of OSHA records
320employers cited
Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Florida
Checking a subcontractor, a client or your own company? Watch Boston Whaler, Inc. and get notified the morning OSHA posts a new citation for it.
Watch this company1958 Unsinkable Street, Flagler Beach, FL 32136 · Boat Building · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
100 Whaler Way, Edgewater, FL 32141 · Boat Building · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1910.147(c)(4)(i) · Lockout/tagout |
Serious | $16,550 | $9,000 | Dec 4, 2025 | Final |
| Citation 1, item 1b 29 CFR 1910.147(f)(3)(ii)(d) · Lockout/tagout |
Other-than-serious | $0 | $0 | Dec 4, 2025 | Final |
400 N Flagler Drive Suite A, West Palm Beach, FL 33401 · Boat Building · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
100 Whaler Way, Edgewater, FL 32141 · Boat Building · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1b 29 CFR 1910.95(d)(1) · Noise |
Other-than-serious | $0 | $7,448 | Jul 29, 2025 | Final |
| Citation 1, item 1c 29 CFR 1910.95(g)(6) · Noise |
Other-than-serious | $0 | $0 | Jul 29, 2025 | Final |
| Citation 1, item 1d 29 CFR 1910.95(k)(1) · Noise |
Other-than-serious | $0 | $0 | Jul 29, 2025 | Final |
100 Whaler Way, Edgewater, FL 32141 · Boat Building · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
100 Whaler Way, Edgewater, FL 32141 · Boat Building · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
100 Whaler Way, Edgewater, FL 32141 · Boat Building · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes |
Serious | $5,100 | $5,100 | Oct 30, 2015 | Final |
| Citation 1, item 2 29 CFR 1910.107(g)(2) · Spray painting and finishing |
Other-than-serious | $5,100 | $0 | Oct 30, 2015 | Final |
| Citation 2, item 1 29 CFR 1910.107(b)(5)(i) · Spray painting and finishing |
Other-than-serious | $0 | $0 | Oct 30, 2015 | Final |
100 Whaler Way - South Hwy. 1, Edgewater, FL 32141 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
100 Whaler Way - South Hwy. 1, Edgewater, FL 32141 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
100 Whaler Way - South Hwy. 1, Edgewater, FL 32141 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.157(g)(2) · Portable fire extinguishers |
Serious | $1,500 | $1,155 | Sep 29, 2000 | Final |
| Citation 2, item 1 29 CFR 1910.1020(g)(1)(i) · Access to employee exposure and medical records |
Other-than-serious | $0 | $0 | Sep 29, 2000 | Final |
100 Whaler Way - South Hwy. 1, Edgewater, FL 32141 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes |
Serious | $1,500 | $975 | Sep 29, 2000 | Final |
| Citation 1, item 2 29 CFR 1910.36(d)(1) · Exit route design |
Other-than-serious | $1,500 | $1,500 | Sep 29, 2000 | Final |
| Citation 1, item 3a 29 CFR 1910.37(q)(2) · Exit routes |
Other-than-serious | $1,500 | $750 | Sep 29, 2000 | Final |
| Citation 1, item 3b 29 CFR 1910.37(q)(6) · Exit routes |
Other-than-serious | $0 | $0 | Sep 29, 2000 | Final |
| Citation 1, item 5a 29 CFR 1910.157(c)(1) · Portable fire extinguishers |
Other-than-serious | $1,500 | $0 | Sep 29, 2000 | Final |
| Citation 1, item 5b 29 CFR 1910.157(c)(1) · Portable fire extinguishers |
Other-than-serious | $0 | $0 | Sep 29, 2000 | Final |
| Citation 1, item 5c 29 CFR 1910.158(c)(2) · Standpipe and hose systems |
Other-than-serious | $0 | $0 | Sep 29, 2000 | Final |
| Citation 1, item 6 29 CFR 1910.179(g)(1)(v) · Overhead and gantry cranes |
Other-than-serious | $1,500 | $100 | Sep 29, 2000 | Final |
| Citation 1, item 7 29 CFR 1910.212(a)(3)(ii) · Machine guarding |
Serious | $1,500 | $1,500 | Sep 29, 2000 | Final |
| Citation 1, item 8 29 CFR 1910.212(b) · Machine guarding |
Serious | $1,500 | $1,500 | Sep 29, 2000 | Final |
| Citation 1, item 9 29 CFR 1910.213(h)(4) · Woodworking machinery |
Serious | $1,500 | $1,500 | Sep 29, 2000 | Final |
| Citation 1, item 10 29 CFR 1910.213(i)(1) · Woodworking machinery |
Serious | $4,500 | $4,500 | Sep 29, 2000 | Final |
| Citation 1, item 11a 29 CFR 1910.303(g)(1) · Electrical equipment, general requirements |
Other-than-serious | $1,125 | $100 | Sep 29, 2000 | Final |
| Citation 1, item 11b 29 CFR 1910.303(h)(3) · Electrical equipment, general requirements |
Other-than-serious | $0 | $0 | Sep 29, 2000 | Final |
| Citation 1, item 12 29 CFR 1910.305(b)(2) · Electrical wiring methods |
Serious | $1,500 | $1,500 | Sep 29, 2000 | Final |
| Citation 2, item 1 29 CFR 1910.22(d)(1) · General requirements |
Other-than-serious | $0 | $0 | Sep 29, 2000 | Final |
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2025, the Edgewater site logged 23 recordable injuries or illnesses among about 807 workers: 3.1 per 100 full-time workers, against a median of 3.8 for its industry. Those cases cost 13 days away from work.
| Site and year | Workers | Cases | Days-away cases | Rate | Industry median |
|---|---|---|---|---|---|
| Boston Whaler - Edgewater Edgewater · 2025 | 807 | 23 | 1 | 3.1 | 3.8 |
| Boston Whaler - Flagler Flagler Beach · 2025 | 278 | 10 | 2 | 3.9 | 3.8 |
| Boston Whaler Edgewater Edgewater · 2024 | 997 | 22 | 2 | 2.4 | 3.8 |
| Boston Whaler Flagler Flagler Beach · 2024 | 380 | 20 | 1 | 5.8 | 3.8 |
Included with any plan: 10 more yearly logs from these sites, back to 2016, with each site's average rate over its latest three years. Already a subscriber? Sign in.
See plansEmployers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 2 reports on file.
Aug 27, 2025, Edgewater: Hospitalization, amputation · amputations involving bone loss · other finger(s) n.e.c.
An employee was unbinding material that was caught in a horizontal band saw. The became unbound and it re-engaged while the employee was reaching for the blade. Two of the employee's fingers were amputated.
Aug 21, 2025, West Palm Beach: Hospitalization · heat exhaustion, fatigue · body systems
An employee was working on a ship in the sun when they began experiencing symptoms of heat exhaustion, resulting in hospitalization.
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.1020(g)(1)(i)
(i) The existence, location, and availability of any records covered by this section;
29 CFR 1910.107(b)(5)(i)
(i) The spraying operations except electrostatic spraying operations shall be so designed, installed and maintained that the average air velocity over the open face of the booth (or booth cross section during spraying operations) shall be not less than 100 linear feet per minute. Electrostatic spraying operations may be conducted with an air velocity over the open face of the booth of not less than 60 linear feet per minute, or more, depending on the volume of the finishing material being applied and its flammability and explosion characteristics. Visible gauges or audible alarm or pressure activated devices shall be installed to indicate or insure that the required air velocity is maintained. Filter rolls shall be inspected to insure proper replacement of filter media.
29 CFR 1910.107(g)(2)
(2) Cleaning. All spraying areas shall be kept as free from the accumulation of deposits of combustible residues as practical, with cleaning conducted daily if necessary. Scrapers, spuds, or other such tools used for cleaning purposes shall be of nonsparking material.