OSHA SearchOSHA records by employer

Boughton's Precast, Inc.: OSHA inspections and violations

Pueblo, Colorado · Other Concrete Product Manufacturing · NAICS 327390

2inspections
9citation items
$14,549current penalties
Sep 18, 2018last inspection

Boughton's Precast, Inc. has 2 OSHA inspections on record in Colorado, the first in 1984.

OSHA's last visit started on Sep 18, 2018 as a planned inspection, in Pueblo.

Across those inspections OSHA issued 9 citation items: 4 serious and 5 other-than-serious.

OSHA proposed $14,549 in penalties and the amount has not been reduced.

Most often, OSHA cited 1910.157, portable fire extinguishers (3 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $4,500. Boughton's Precast, Inc. averages $14,549 over 1 cited inspection in that time.

Boughton's Precast, Inc.: OSHA citation items per year, 1984 to 2018
Citation items per year, by inspection date.

Colorado · latest 90 days of OSHA records

132employers cited

Get notified the morning OSHA posts each new citation in Colorado: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Colorado

Checking a subcontractor, a client or your own company? Watch Boughton's Precast, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343472338 OPENED SEP 18, 2018Closed

Planned · Complete · Safety · 25 employees at the site · Closed Nov 19, 2018

1724 Aspen Circle, Pueblo, CO 81006 · Other Concrete Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.28(b)(1)(i) · Fall protection in general industry
Serious$3,696$3,696Oct 19, 2018Final
Citation 1, item 2
29 CFR 1910.253(b)(5)(ii)(i) · Gas welding and cutting
Serious$2,956$2,956Oct 19, 2018Final
Citation 1, item 3
29 CFR 1910.305(b)(2)(i) · Electrical wiring methods
Serious$3,696$3,696Oct 19, 2018Final
Citation 1, item 4
29 CFR 1910.1200(g)(8) · Hazard communication
Serious$2,956$2,956Oct 19, 2018Final
Citation 2, item 1a
29 CFR 1910.157(c)(1) · Portable fire extinguishers
Other-than-serious$415$415Oct 19, 2018Final
Citation 2, item 1b
29 CFR 1910.157(c)(4) · Portable fire extinguishers
Other-than-serious$0$0Oct 19, 2018Final
Citation 2, item 1c
29 CFR 1910.157(e)(1) · Portable fire extinguishers
Other-than-serious$0$0Oct 19, 2018Final
Citation 2, item 2
29 CFR 1910.178(p)(1) · Forklifts and other powered industrial trucks
Other-than-serious$415$415Oct 19, 2018Final
Citation 2, item 3
29 CFR 1910.304(f)(1)(iv) · Grounding and circuit protection
Other-than-serious$415$415Oct 19, 2018Final

Inspection 1567379 OPENED AUG 1, 1984Closed

Planned · No inspection · Safety · 8 employees at the site · Closed Aug 3, 1984

1724 Aspen Circle, Pueblo, CO 81006 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(g)(8)

(8) The employer shall maintain in the workplace copies of the required safety data sheets for each hazardous chemical, and shall ensure that they are readily accessible during each work shift to employees when they are in their work area(s). (Electronic access and other alternatives to maintaining paper copies of the safety data sheets are permitted as long as no barriers to immediate employee access in each workplace are created by such options.)

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.157(c)(1)

(c) General requirements. (1) The employer shall provide portable fire extinguishers and shall mount, locate and identify them so that they are readily accessible to employees without subjecting the employees to possible injury.

29 CFR 1910.157(c)(4)

(4) The employer shall assure that portable fire extinguishers are maintained in a fully charged and operable condition and kept in their designated places at all times except during use.

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.253 · Gas welding and cutting

29 CFR 1910.28 · Fall protection in general industry

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods

Other other concrete product manufacturing employers in Colorado

Alert subscribers get notified of each newly cited employer in Colorado the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.