OSHA SearchOSHA records by employer

Bpi, Inc.: OSHA inspections and violations

Mc Kees Rocks, Pennsylvania · All Other Miscellaneous Nonmetallic Mineral Product Manufacturing · NAICS 327999

4inspections
24citation items
$26,589current penalties
Sep 4, 2025last inspection

Bpi, Inc. has 4 OSHA inspections on record in Pennsylvania, the first in 1999.

OSHA's last visit started on Sep 4, 2025 after a complaint, in New Castle.

Across those inspections OSHA issued 24 citation items: 18 serious and 6 other-than-serious.

OSHA proposed $35,841 in penalties. After settlements and reviews the total is $26,589, down 26%.

Most often, OSHA cited 1910.303, electrical equipment, general requirements (5 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $4,500. Bpi, Inc. averages $5,909 over 1 cited inspection in that time.

Bpi, Inc. also files yearly injury logs with OSHA, summarized below.

Bpi, Inc.: OSHA citation items per year, 1999 to 2025
Citation items per year, by inspection date.

Want to know if OSHA cites Bpi, Inc. again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 348482548 OPENED SEP 4, 2025Closed

Complaint · Partial · Health · 25 employees at the site · Closed Mar 27, 2026

1 Rockwell Drive, New Castle, PA 16102 · All Other Miscellaneous Nonmetallic Mineral Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
OSH Act Section 5(a)(1) · General Duty Clause
Serious$8,441$5,909Feb 23, 2026Final

Inspection 339485054 OPENED NOV 14, 2013Closed

Referral · Partial · Health · 12 employees at the site · Closed Aug 25, 2014

149 Nichol Avenue, Mc Kees Rocks, PA 15136 · Ground or Treated Mineral and Earth Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1b
29 CFR 1910.1000(e) · Air contaminants
Other-than-serious$0$0Apr 28, 2014Final

Inspection 339480519 OPENED NOV 12, 2013Closed

Referral · Partial · Safety · 12 employees at the site · Closed Jul 11, 2014

149 Nichol Avenue, Mc Kees Rocks, PA 15136 · All Other Miscellaneous Nonmetallic Mineral Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
OSH Act Section 5(a)(1) · General Duty Clause
Serious$2,800$1,960Mar 26, 2014Final
Citation 1, item 2a
29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes
Serious$4,200$2,940Mar 26, 2014Final
Citation 1, item 2b
29 CFR 1910.23(c)(3) · Guarding floor and wall openings and holes
Serious$0$0Mar 26, 2014Final
Citation 1, item 3
29 CFR 1910.151(b) · First aid and eyewash
Serious$4,900$3,430Mar 26, 2014Final
Citation 1, item 4
29 CFR 1910.147(c)(7)(i) · Lockout/tagout
Serious$2,800$1,960Mar 26, 2014Final
Citation 1, item 5
29 CFR 1910.212(a)(2) · Machine guarding
Serious$4,900$3,430Mar 26, 2014Final
Citation 1, item 6a
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Serious$2,800$1,960Mar 26, 2014Final
Citation 1, item 6b
29 CFR 1910.303(b)(7)(i) · Electrical equipment, general requirements
Serious$0$0Mar 26, 2014Final
Citation 1, item 6c
29 CFR 1910.303(b)(7)(iii) · Electrical equipment, general requirements
Serious$0$0Mar 26, 2014Final
Citation 1, item 6d
29 CFR 1910.303(b)(7)(iv) · Electrical equipment, general requirements
Serious$0$0Mar 26, 2014Final
Citation 1, item 6e
29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods
Serious$0$0Mar 26, 2014Final
Citation 2, item 1
29 CFR 1910.305(b)(2)(i) · Electrical wiring methods
Other-than-serious$0$0Mar 26, 2014Final

Inspection 302812235 OPENED AUG 9, 1999Closed

Complaint · Partial · Safety · 12 employees at the site · Closed Sep 9, 1999

149 Nichol Avenue, Mrie Industrial Park, Mckees Rocks, PA 15136 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
OSH Act Section 5(a)(1) · General Duty Clause
Serious$2,500$2,500Aug 24, 1999Closed
Citation 1, item 2
29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes
Serious$750$750Aug 24, 1999Closed
Citation 1, item 3a
29 CFR 1910.147(c)(1) · Lockout/tagout
Serious$1,000$1,000Aug 24, 1999Closed
Citation 1, item 3b
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$0$0Aug 24, 1999Closed
Citation 1, item 3c
29 CFR 1910.147(c)(7)(i) · Lockout/tagout
Serious$0$0Aug 24, 1999Closed
Citation 1, item 4
29 CFR 1910.219(e)(3)(i) · Belts, pulleys and power-transmission parts
Serious$750$750Aug 24, 1999Closed
Citation 2, item 1
29 CFR 1904.6 · Determination of new cases
Other-than-serious$0$0Aug 24, 1999Closed
Citation 2, item 2
29 CFR 1910.303(f) · Electrical equipment, general requirements
Other-than-serious$0$0Aug 24, 1999Closed
Citation 2, item 3
29 CFR 1910.305(b)(2) · Electrical wiring methods
Other-than-serious$0$0Aug 24, 1999Closed
Citation 2, item 4
29 CFR 1910.305(g)(2)(ii) · Electrical wiring methods
Other-than-serious$0$0Aug 24, 1999Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2024, the New Castle site logged 1 recordable injury or illness among about 27 workers: 4.0 per 100 full-time workers, against a median of 2.6 for its industry. Those cases cost 50 days away from work.

Site and yearWorkersCasesDays-away casesRateIndustry median
BPI, Inc. New Castle, PA
New Castle · 2024
27 114.02.6
BPI Inc., New Castle, PA
New Castle · 2022
26 000.02.6

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1904.6 · Determination of new cases

29 CFR 1910.1000 · Air contaminants

29 CFR 1910.1000(e)

(e) To achieve compliance with paragraphs (a) through (d) of this section, administrative or engineering controls must first be determined and implemented whenever feasible. When such controls are not feasible to achieve full compliance, protective equipment or any other protective measures shall be used to keep the exposure of employees to air contaminants within the limits prescribed in this section. Any equipment and/or technical measures used for this purpose must be approved for each particular use by a competent industrial hygienist or other technically qualified person. Whenever respirators are used, their use shall comply with 1910.134.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(1)

(c) General—(1) Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, start up or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source, and rendered inoperative.

29 CFR 1910.147(c)(4)(i)

(4) Energy control procedure. (i) Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.

29 CFR 1910.151 · First aid and eyewash

29 CFR 1910.212 · Machine guarding

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

OSH Act Section 5 · General Duty Clause

Other all other miscellaneous nonmetallic mineral product manufacturing employers in Pennsylvania

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.