OSHA SearchOSHA records by employer

Branch Metal Processing Corporation: OSHA inspections and violations

St. Louis, Missouri · Nonferrous Metal (except Aluminum) Smelting and Refining · NAICS 331411

6inspections
31citation items
$9,500current penalties
Jul 14, 2015last inspection

OSHA has inspected Branch Metal Processing Corporation 6 times in Missouri since 1985.

The latest one began on Jul 14, 2015 after a complaint, in Saint Louis.

Those inspections ended with 31 citation items: 24 serious and 7 other-than-serious.

Penalties were first proposed at $20,350 and now stand at $9,500, 53% lower after settlements or reviews.

Hazard communication comes up most often in these citations: 5 items under 1910.1200.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Branch Metal Processing Corporation averages $7,000 (1 cited inspection).

Branch Metal Processing Corporation: OSHA citation items per year, 1985 to 2015
Citation items per year, by inspection date.

Missouri · latest 90 days of OSHA records

126employers cited

Get notified the morning OSHA posts each new citation in Missouri: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Missouri

Checking a subcontractor, a client or your own company? Watch Branch Metal Processing Corporation and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340772797 OPENED JUL 14, 2015Closed

Complaint · Complete · Safety · 16 employees at the site · Closed Aug 25, 2015

620 St. Cyr Road, Saint Louis, MO 63137 · Recyclable Material Merchant Wholesalers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.23(e)(1) · Guarding floor and wall openings and holes
Serious$2,000$1,000Jul 24, 2015Final
Citation 1, item 1b
29 CFR 1910.23(e)(2) · Guarding floor and wall openings and holes
Serious$0$0Jul 24, 2015Final
Citation 1, item 2
29 CFR 1910.101(b) · Compressed gases (general requirements)
Serious$2,000$2,000Jul 24, 2015Final
Citation 1, item 4a
29 CFR 1910.132(d)(2) · Personal protective equipment, general requirements
Serious$2,000$1,000Jul 24, 2015Final
Citation 1, item 4b
29 CFR 1910.138(a) · Gloves and hand protection
Serious$0$0Jul 24, 2015Final
Citation 1, item 5b
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$0$0Jul 24, 2015Final
Citation 1, item 5c
29 CFR 1910.147(c)(4)(ii) · Lockout/tagout
Serious$0$0Jul 24, 2015Final
Citation 1, item 5d
29 CFR 1910.147(c)(6)(i) · Lockout/tagout
Serious$0$0Jul 24, 2015Final
Citation 1, item 6
29 CFR 1910.169(b)(3)(iv) · Air receivers
Other-than-serious$2,000$2,000Jul 24, 2015Final
Citation 1, item 7a
29 CFR 1910.305(g)(1)(iv) · Electrical wiring methods
Serious$2,000$1,000Jul 24, 2015Final
Citation 1, item 7b
29 CFR 1910.305(g)(2)(ii) · Electrical wiring methods
Serious$0$0Jul 24, 2015Final

Inspection 332838333 OPENED MAR 15, 2012Closed

Planned · Records only · Safety · 13 employees at the site · Closed May 3, 2012

620 St. Cyr Road, Saint Louis, MO 63137 · Nonferrous Metal (except Aluminum) Smelting and Refining · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 109581678 OPENED SEP 1, 1995Closed

Complaint · Partial · Safety · 7 employees at the site · Closed Sep 5, 1995

620 St. Cyr Rd., St. Louis, MO 63137 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 106547516 OPENED MAR 3, 1993Closed

Referral · Partial · Health · 8 employees at the site · Closed Mar 10, 1993

620 St. Cyr Rd., St. Louis, MO 63137 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 106695851 OPENED JUL 17, 1992Closed

Complaint · Partial · Safety · 9 employees at the site · Closed Nov 16, 1993

620 St. Cyr Rd., St. Louis, MO 63137 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.141(a)(5) · Sanitation
Other-than-serious$450$0Aug 14, 1992Final
Citation 1, item 3
29 CFR 1910.147(c)(1) · Lockout/tagout
Serious$750$400Aug 14, 1992Final
Citation 1, item 4
29 CFR 1910.157(c)(4) · Portable fire extinguishers
Other-than-serious$600$0Aug 14, 1992Final
Citation 1, item 5
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$750$250Aug 14, 1992Final
Citation 1, item 6
29 CFR 1910.212(a)(5) · Machine guarding
Serious$450$200Aug 14, 1992Final
Citation 1, item 7
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Serious$450$450Aug 14, 1992Final
Citation 1, item 8
29 CFR 1910.219(f)(1) · Belts, pulleys and power-transmission parts
Serious$750$0Aug 14, 1992Final
Citation 1, item 9
29 CFR 1910.303(f) · Electrical equipment, general requirements
Serious$750$400Aug 14, 1992Final
Citation 1, item 10
29 CFR 1910.304(f)(4) · Grounding and circuit protection
Other-than-serious$750$200Aug 14, 1992Final
Citation 1, item 11
29 CFR 1910.305(b)(1) · Electrical wiring methods
Serious$750$0Aug 14, 1992Final
Citation 1, item 12
29 CFR 1910.305(d) · Electrical wiring methods
Serious$750$0Aug 14, 1992Final
Citation 1, item 13 Serious$750$400Aug 14, 1992Final
Citation 1, item 14
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$600$200Aug 14, 1992Final
Citation 1, item 15a
29 CFR 1910.1200(f)(5)(i) · Hazard communication
Serious$600$0Aug 14, 1992Final
Citation 1, item 15b
29 CFR 1910.1200(f)(5)(ii) · Hazard communication
Serious$0$0Aug 14, 1992Final
Citation 1, item 16
29 CFR 1910.1200(g)(8) · Hazard communication
Serious$600$0Aug 14, 1992Final
Citation 1, item 17
29 CFR 1910.1200(h) · Hazard communication
Serious$600$0Aug 14, 1992Final
Citation 2, item 1 Other-than-serious$0$0Aug 14, 1992Final
Citation 2, item 2 Other-than-serious$0$0Aug 14, 1992Final
Citation 2, item 3 Other-than-serious$0$0Aug 14, 1992Final

Inspection 100035146 OPENED AUG 22, 1985Closed

Planned · Complete · Health · 11 employees at the site · Closed Aug 22, 1985

620 St Cyr Road, St Louis, MO 63137 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.101 · Compressed gases (general requirements)

29 CFR 1910.101(b)

(b) Compressed gases. The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks shall be in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in § 1910.6.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1910.1200(f)(5)(i)

(5) Transportation. (i) Chemical manufacturers, importers, or distributors shall ensure that each container of hazardous chemicals leaving the workplace is labeled, tagged, or marked in accordance with this section in a manner which does not conflict with the requirements of the Hazardous Materials Transportation Act (49 U.S.C. 5101 et seq.) and regulations issued under that Act by the Department of Transportation (49 CFR subtitle B).

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.138 · Gloves and hand protection

29 CFR 1910.141 · Sanitation

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.169 · Air receivers

29 CFR 1910.212 · Machine guarding

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.332 · Training

Other nonferrous metal (except aluminum) smelting and refining employers in Missouri

Alert subscribers get notified of each newly cited employer in Missouri the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.