OSHA SearchOSHA records by employer

Brand X Hydrovac Services, Inc.: OSHA inspections and violations

Denver, Colorado · Other Heavy and Civil Engineering Construction · NAICS 237990

2inspections
2citation items
$9,446current penalties
Nov 7, 2022last inspection

Since 2019, OSHA inspectors have visited Brand X Hydrovac Services, Inc. in Colorado 2 times.

The most recent inspection opened on Nov 7, 2022 to follow up on an earlier case, in Longmont.

In all, OSHA issued 2 citation items: 2 serious.

The penalties, $9,446 in total, stand where OSHA first set them.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Brand X Hydrovac Services, Inc. averages $9,446 across 1 cited inspection.

2 inspections on this page followed a fatal incident.

Brand X Hydrovac Services, Inc.: OSHA citation items per year, 2019 to 2022
Citation items per year, by inspection date.

Colorado · latest 90 days of OSHA records

142employers cited

Get notified the morning OSHA posts each new citation in Colorado: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Colorado

Checking a subcontractor, a client or your own company? Watch Brand X Hydrovac Services, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346279060 OPENED NOV 7, 2022Closed

Follow-up · Partial · Health · 70 employees at the site · Closed Nov 7, 2022

13770 Deere Ct, Longmont, CO 80504 · Other Heavy and Civil Engineering Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 344275045 OPENED AUG 30, 2019Closed

Fatality or catastrophe · Partial · Safety · 2 employees at the site · Closed Sep 29, 2021

Stapleton S Dr And Airlawn Rd., Denver, CO 80216 · Other Heavy and Civil Engineering Construction · OSHA's record · Phone and website on Google Maps

Incident on Aug 29, 2019 (fatal): Employee is electrocuted when boom strikes against active po

At 4:15 p.m. on August 29, 2019, an employee was working from a vacuum truck boom while setting up utility lines and was electrocuted when the boom struck a live power line, killing him.

Incident on Aug 29, 2019 (fatal): Employee is killed by electrocution while potholing for util

At 4:15 p.m. on August 29, 2019, an employee was potholing to check for utilities using the hose from a vacuum truck. While conducting his work, the vacuum truck boom struck a power line and the worker was killed by electrocution.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.21(b)(2) · Construction safety training
Serious$9,446$9,446Jan 24, 2020Final
Citation 1, item 1b
29 CFR 1926.416(a)(1) · Electrical safety in construction
Serious$0$0Jan 24, 2020Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.21 · Construction safety training

29 CFR 1926.21(b)(2)

(2) The employer shall instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his work environment to control or eliminate any hazards or other exposure to illness or injury.

29 CFR 1926.416 · Electrical safety in construction

29 CFR 1926.416(a)(1)

(a) Protection of employees. (1) No employer shall permit an employee to work in such proximity to any part of an electric power circuit that the employee could contact the electric power circuit in the course of work, unless the employee is protected against electric shock by deenergizing the circuit and grounding it or by guarding it effectively by insulation or other means.

Other other heavy and civil engineering construction employers in Colorado

Alert subscribers get notified of each newly cited employer in Colorado the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.