OSHA SearchOSHA records by employer

W.W. Clyde & Co.: OSHA inspections and violations

Thornton, Colorado · Other Heavy and Civil Engineering Construction · NAICS 237990

1inspections
2citation items
$23,170current penalties
Mar 3, 2026last inspection

OSHA has inspected W.W. Clyde & Co. once in Colorado.

The inspection began on Mar 3, 2026 as a planned inspection, in Thornton.

That inspection ended with 2 citation items: 2 serious.

Penalties were first proposed at $33,100 and now stand at $23,170, 30% lower after settlements or reviews.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and W.W. Clyde & Co. averages $23,170 (1 cited inspection).

W.W. Clyde & Co.: OSHA citation items per year, 2026 to 2026
Citation items per year, by inspection date.

Colorado · latest 90 days of OSHA records

139employers cited

Get notified the morning OSHA posts each new citation in Colorado: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Colorado

Checking a subcontractor, a client or your own company? Watch W.W. Clyde & Co. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348781584 OPENED MAR 3, 2026Closed

Planned · Partial · Safety · 55 employees at the site · Closed Jun 29, 2026

14707 Quebec Street Thornton Water Project, Segment A, Thornton, CO 80602 · Other Heavy and Civil Engineering Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.652(b)(2) · Trench protection
Serious$16,550$11,585Jun 5, 2026Final
Citation 1, item 2
29 CFR 1926.651(c)(2) · Excavations
Serious$16,550$11,585Jun 5, 2026Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.651 · Excavations

29 CFR 1926.651(c)(2)

(2) Means of egress from trench excavations. A stairway, ladder, ramp or other safe means of egress shall be located in trench excavations that are 4 feet (1.22 m) or more in depth so as to require no more than 25 feet (7.62 m) of lateral travel for employees.

29 CFR 1926.652 · Trench protection

29 CFR 1926.652(b)(2)

(2) Option (2)—Determination of slopes and configurations using Appendices A and B. Maximum allowable slopes, and allowable configurations for sloping and benching systems, shall be determined in accordance with the conditions and requirements set forth in appendices A and B to this subpart.

Other other heavy and civil engineering construction employers in Colorado

Alert subscribers get notified of each newly cited employer in Colorado the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.