OSHA SearchOSHA records by employer

Brent Industries, Inc.: OSHA inspections and violations

Brent, Alabama · Industrial Launderers · NAICS 812332

2inspections
10citation items
$27,300current penalties
Mar 12, 2015last inspection

OSHA has inspected Brent Industries, Inc. 2 times in Alabama since 1980.

The latest one began on Mar 12, 2015 after a fatality or catastrophe, in Brent.

Those inspections ended with 10 citation items: 9 serious and 1 other-than-serious.

Penalties were first proposed at $32,200 and now stand at $27,300, 15% lower after settlements or reviews.

Personal protective equipment, general requirements comes up most often in these citations: 2 items under 1910.132.

How that compares: the median penalty per cited inspection for repair and personal services employers since 2015 is $1,200, and Brent Industries, Inc. averages $27,300 (1 cited inspection).

1 inspection on this page followed a fatal incident.

Brent Industries, Inc.: OSHA citation items per year, 1980 to 2015
Citation items per year, by inspection date.

Alabama · latest 90 days of OSHA records

99employers cited

Get notified the morning OSHA posts each new citation in Alabama: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Alabama

Checking a subcontractor, a client or your own company? Watch Brent Industries, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340457118 OPENED MAR 12, 2015Closed

Fatality or catastrophe · Complete · Health · 22 employees at the site · Closed Jun 20, 2016

695 S. Scottsville Rd, Brent, AL 35034 · Industrial Launderers · OSHA's record · Phone and website on Google Maps

Incident on Mar 11, 2015 (fatal): One employee is killed and one is burned from an explosion a

At 1:45 p.m. on March 11, 2015, two employees (operators) were working in a commercial petroleum dry cleaning facility which utilizes a petroleum solvent to dry clean soiled industrial items such as shop towels and gloves. Employee #1 and Employee #2 were working in the Processing Area at the Washex Washer #2, #3, & #4. The two employee operators loaded each Washer with approximately 500 pounds of laundry. The wash cycle was initiated by the operator and solvent was pumped from exterior tank to the Washer. Each washer utilizes 150 gallons of mineral spirit to process each laundry load. The industrial washer(s) uses a washing and extraction process prior to the items being transferred to another machines for drying. The soiled laundry was loaded into the machines(s) and the cleaning solvent was automatically injected. The machine contents were agitated for a period, then spun at high speed to extract the solvent. The 3 Washex Washers that were being operated probably were being drained when an ignition of flammable vapor occurred at the #4 Washex Washer and subsequently the fire spread to the other washers and eventually engulfed the facility. Employee #1 was killed and his body was found at the #4 Washer after the fire was extinguished. Employee #2 sustained burns to his body prior evacuating the facility and was hospitalized due to burns. Employee #1 was most likely incapacitated from the initial fire and the explosion that occurred at the #4 Washex Washer due to the ignition of the Mineral Sprits. The pressure created by the ignition of vapor blew the exterior doors off of #4 Washex Washer. Fire and over-pressurization occurred at each washer wthin seconds of the initial blast. The ignition of the Stoddard solvent vapor in the Washex washer #4 was most likely the result of an electrical spark being generated when a sling with metal grommets was inadvertently placed into the washer. inadvertently placed into the washer.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes
Serious$2,800$2,800Sep 9, 2015Final
Citation 1, item 3a
29 CFR 1910.106(e)(5)(iv) · Flammable liquids
Serious$4,900$4,900Sep 9, 2015Final
Citation 1, item 3b
29 CFR 1910.106(e)(5)(iii) · Flammable liquids
Serious$4,900$0Sep 9, 2015Final
Citation 1, item 4
29 CFR 1910.1200(h)(3)(ii) · Hazard communication
Serious$6,300$6,300Sep 9, 2015Final
Citation 1, item 5
29 CFR 1910.37(a)(4) · Exit routes
Serious$4,900$4,900Sep 9, 2015Final
Citation 1, item 6a
29 CFR 1910.132(a) · Personal protective equipment, general requirements
Serious$4,200$4,200Sep 9, 2015Final
Citation 1, item 6b
29 CFR 1910.132(f)(1)(ii) · Personal protective equipment, general requirements
Serious$0$0Sep 9, 2015Final
Citation 1, item 6c
29 CFR 1910.138(a) · Gloves and hand protection
Serious$0$0Sep 9, 2015Final
Citation 1, item 7
29 CFR 1910.1200(h)(1) · Hazard communication
Serious$4,200$4,200Sep 9, 2015Final

Inspection 13248190 OPENED MAY 20, 1980Closed

Planned · Complete · Safety · 18 employees at the site · Closed Jun 13, 1980

Scottsville Road, Brent, AL 35034 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Other-than-serious$0$0May 29, 1980Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(e)(5)(iii)

(iii) Special extinguishers. Special extinguishing equipment such as that utilizing foam, inert gas, or dry chemical shall be provided as the need is indicated by the special hazards of operation dispensing and storage.

29 CFR 1910.106(e)(5)(iv)

(iv) Special hazards. Where the need is indicated by special hazards of operation, flammable liquid processing equipment, major piping, and supporting steel shall be protected by approved water spray systems, deluge systems, approved fire-resistant coatings, insulation, or any combination of these.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(h)(1)

(h) Employee information and training. (1) Employers shall provide employees with effective information and training on hazardous chemicals in their work area at the time of their initial assignment, and whenever a new chemical hazard the employees have not previously been trained about is introduced into their work area. Information and training may be designed to cover categories of hazards (e.g., flammability, carcinogenicity) or specific chemicals. Chemical-specific information must always be available through labels and safety data sheets.

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.138 · Gloves and hand protection

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.37 · Exit routes

Other industrial launderers employers in Alabama

Alert subscribers get notified of each newly cited employer in Alabama the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.