Inspection 345074645 OPENED DEC 21, 2020Closed
330 East Hebron Street Suite A, Charlotte, NC 28273 · All Other Automotive Repair and Maintenance · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Charlotte, North Carolina · All Other Automotive Repair and Maintenance · NAICS 811198
Brimworks Inc. has 2 OSHA inspections on record in North Carolina, the first in 2019.
OSHA's last visit started on Dec 21, 2020 to follow up on an earlier case, in Charlotte.
Across those inspections OSHA issued 18 citation items: 12 serious and 6 other-than-serious.
OSHA proposed $14,100 in penalties. After settlements and reviews the total is $11,986, down 15%.
Most often, OSHA cited 1910.107, spray painting and finishing (6 items).
For context, across all repair and personal services employers the median penalty per cited inspection since 2015 is $1,200. Brimworks Inc. averages $11,986 over 1 cited inspection in that time.
North Carolina · latest 90 days of OSHA records
230employers cited
Get notified the morning OSHA posts each new citation in North Carolina: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in North Carolina
Checking a subcontractor, a client or your own company? Watch Brimworks Inc. and get notified the morning OSHA posts a new citation for it.
Watch this company330 East Hebron Street Suite A, Charlotte, NC 28273 · All Other Automotive Repair and Maintenance · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
330 East Hebron Street Suite A, Charlotte, NC 28273 · All Other Automotive Repair and Maintenance · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.106(e)(6)(i) · Flammable liquids |
Serious | $2,100 | $1,785 | Mar 19, 2020 | Final |
| Citation 1, item 2 29 CFR 1910.107(b)(5)(i) · Spray painting and finishing |
Serious | $900 | $765 | Mar 19, 2020 | Final |
| Citation 1, item 3 29 CFR 1910.107(b)(9) · Spray painting and finishing |
Serious | $1,500 | $1,275 | Mar 19, 2020 | Final |
| Citation 1, item 4a 29 CFR 1910.107(c)(2) · Spray painting and finishing |
Serious | $2,100 | $1,785 | Mar 19, 2020 | Final |
| Citation 1, item 4b 29 CFR 1910.107(g)(7) · Spray painting and finishing |
Serious | $0 | $0 | Mar 19, 2020 | Final |
| Citation 1, item 4c 29 CFR 1910.107(l)(4)(iii) · Spray painting and finishing |
Serious | $0 | $0 | Mar 19, 2020 | Final |
| Citation 1, item 5 29 CFR 1910.107(e)(2) · Spray painting and finishing |
Serious | $1,500 | $1,275 | Mar 19, 2020 | Final |
| Citation 1, item 6 29 CFR 1910.151(c) · First aid and eyewash |
Serious | $2,100 | $1,785 | Mar 19, 2020 | Final |
| Citation 1, item 7 29 CFR 1910.242(b) · Hand and power tools |
Serious | $1,500 | $1,275 | Mar 19, 2020 | Final |
| Citation 1, item 8a 29 CFR 1910.1200(e)(1) · Hazard communication |
Serious | $1,500 | $1,275 | Mar 19, 2020 | Final |
| Citation 1, item 8b 29 CFR 1910.1200(f)(6) · Hazard communication |
Serious | $0 | $0 | Mar 19, 2020 | Final |
| Citation 1, item 8c 29 CFR 1910.1200(h)(1) · Hazard communication |
Serious | $0 | $0 | Mar 19, 2020 | Final |
| Citation 2, item 1 29 CFR 1910.132(d)(2) · Personal protective equipment, general requirements |
Other-than-serious | $450 | $383 | Mar 19, 2020 | Final |
| Citation 2, item 2a 29 CFR 1910.134(c)(1) · Respiratory protection |
Other-than-serious | $450 | $383 | Mar 19, 2020 | Final |
| Citation 2, item 2b 29 CFR 1910.134(e)(1) · Respiratory protection |
Other-than-serious | $0 | $0 | Mar 19, 2020 | Final |
| Citation 2, item 2c 29 CFR 1910.134(f)(2) · Respiratory protection |
Other-than-serious | $0 | $0 | Mar 19, 2020 | Final |
| Citation 2, item 2d 29 CFR 1910.134(k)(3) · Respiratory protection |
Other-than-serious | $0 | $0 | Mar 19, 2020 | Final |
| Citation 2, item 3 29 CFR 1910.252(b)(2)(iii) · Welding fire safety |
Other-than-serious | $0 | $0 | Mar 19, 2020 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.106(e)(6)(i)
(6) Sources of ignition—(i) General. Adequate precautions shall be taken to prevent the ignition of flammable vapors. Sources of ignition include but are not limited to open flames; lightning; smoking; cutting and welding; hot surfaces; frictional heat; static, electrical, and mechanical sparks; spontaneous ignition, including heat-producing chemical reactions; and radiant heat.
29 CFR 1910.107(b)(5)(i)
(i) The spraying operations except electrostatic spraying operations shall be so designed, installed and maintained that the average air velocity over the open face of the booth (or booth cross section during spraying operations) shall be not less than 100 linear feet per minute. Electrostatic spraying operations may be conducted with an air velocity over the open face of the booth of not less than 60 linear feet per minute, or more, depending on the volume of the finishing material being applied and its flammability and explosion characteristics. Visible gauges or audible alarm or pressure activated devices shall be installed to indicate or insure that the required air velocity is maintained. Filter rolls shall be inspected to insure proper replacement of filter media.
29 CFR 1910.107(b)(9)
(9) Cleaning. Spray booths shall be so installed that all portions are readily accessible for cleaning. A clear space of not less than 3 feet on all sides shall be kept free from storage or combustible construction.
Alert subscribers get notified of each newly cited employer in North Carolina the morning it is posted. See the alert plans.