OSHA SearchOSHA records by employer

Brunelle Brothers Electric: OSHA inspections and violations

Woburn, Massachusetts · Electrical Contractors and Other Wiring Installation Contractors · NAICS 238210

2inspections
3citation items
$4,050current penalties
Mar 31, 2021last inspection

Since 2002, OSHA inspectors have visited Brunelle Brothers Electric in Massachusetts 2 times.

The most recent inspection opened on Mar 31, 2021 on a referral, in Billerica.

In all, OSHA issued 3 citation items: 3 serious.

The proposed penalties came to $11,657; today they stand at $4,050, 65% less.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Brunelle Brothers Electric averages $3,000 across 1 cited inspection.

It reported 1 severe injury to OSHA since 2015.

Brunelle Brothers Electric: OSHA citation items per year, 2002 to 2021
Citation items per year, by inspection date.

Massachusetts · latest 90 days of OSHA records

256employers cited

4 of them in the same industry

Get notified the morning OSHA posts each new citation in Massachusetts: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Massachusetts

Checking a subcontractor, a client or your own company? Watch Brunelle Brothers Electric and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345225841 OPENED MAR 31, 2021Closed

Referral · Partial · Safety · 60 employees at the site · Closed Nov 8, 2021

164 Lexington Road, Billerica, MA 01821 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.21(b)(2) · Construction safety training
Serious$9,557$3,000May 10, 2021Final

Inspection 303809396 OPENED FEB 8, 2002Closed

Unprogrammed other · Complete · Safety · 12 employees at the site · Closed Jun 19, 2002

51-57 Cedar Ct., Woburn, MA 01801 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.404(b)(1)(i) · Ground-fault protection on job sites
Serious$1,500$750Apr 3, 2002Closed
Citation 1, item 2
29 CFR 1926.405(b)(1) · Job-site wiring
Serious$600$300Apr 3, 2002Closed

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.

Mar 31, 2021, Billerica: Hospitalization · avulsions, enucleations · ear(s)

Two employees were rolling a wooden cable spool that weighed approximately 500 lbs. down a flight of stairs. The employees were in the process of spinning the spool around a stair railing when it suddenly rolled down the stairs and pushed an employee to the second deck. The employee lost consciousness and suffered a partial ear avulsion.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.21 · Construction safety training

29 CFR 1926.21(b)(2)

(2) The employer shall instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his work environment to control or eliminate any hazards or other exposure to illness or injury.

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.404(b)(1)(i)

(b) Branch circuits—(1) Ground-fault protection—(i) General. The employer shall use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. These requirements are in addition to any other requirements for equipment grounding conductors.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.405(b)(1)

(b) Cabinets, boxes, and fittings—(1) Conductors entering boxes, cabinets, or fittings. Conductors entering boxes, cabinets, or fittings shall be protected from abrasion, and openings through which conductors enter shall be effectively closed. Unused openings in cabinets, boxes, and fittings shall also be effectively closed.

Other electrical contractors and other wiring installation contractors employers in Massachusetts

Alert subscribers get notified of each newly cited employer in Massachusetts the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.