OSHA SearchOSHA records by employer

Buildings by Design, LLC: OSHA inspections and violations

De Beque, Colorado · Commercial and Institutional Building Construction · NAICS 236220

4inspections
3citation items
$6,273current penalties
Dec 10, 2018last inspection

OSHA has inspected Buildings by Design, LLC 4 times in Colorado since 2011.

The latest one began on Dec 10, 2018, in Fountain.

Those inspections ended with 3 citation items: 3 serious.

Penalties were first proposed at $6,273 and still stand at $6,273.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Buildings by Design, LLC averages $2,273 (1 cited inspection).

Buildings by Design, LLC: OSHA citation items per year, 2011 to 2018
Citation items per year, by inspection date.

Colorado · latest 90 days of OSHA records

136employers cited

3 of them in the same industry

Get notified the morning OSHA posts each new citation in Colorado: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Colorado

Checking a subcontractor, a client or your own company? Watch Buildings by Design, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343684346 OPENED DEC 10, 2018Closed

Unprogrammed other · Partial · Safety · 2 employees at the site · Closed Mar 27, 2019

1201 Rmb Ct., Fountain, CO 80817 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.20(b)(2) · Construction safety programs
Serious$2,273$2,273Mar 4, 2019Final

Inspection 339804171 OPENED JUN 9, 2014Closed

Follow-up · No inspection · Safety · 18 employees at the site · Closed Jun 12, 2014

4615 State Highway 6, De Beque, CO 81630 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 339655417 OPENED JAN 17, 2014Closed

Planned · Partial · Safety · 18 employees at the site · Closed Jul 11, 2014

4615 State Highway 6, De Beque, CO 81630 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(10) · Fall protection in construction
Serious$2,000$2,000Apr 29, 2014Final
Citation 1, item 2
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$2,000$2,000Apr 29, 2014Final

Inspection 330294125 OPENED APR 5, 2011Closed

Complaint · Partial · Safety · 5 employees at the site · Closed Apr 7, 2011

779 Sulpher Creek Road, Meeker, CO 81641 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.20 · Construction safety programs

29 CFR 1926.20(b)(2)

(2) Such programs shall provide for frequent and regular inspections of the job sites, materials, and equipment to be made by competent persons designated by the employers.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.501(b)(10)

(10) Roofing work on Low-slope roofs. Except as otherwise provided in paragraph (b) of this section, each employee engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet (1.8 m) or more above lower levels shall be protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width (see appendix A to subpart M of this part), the use of a safety monitoring system alone [i.e. without the warning line system] is permitted.

Other commercial and institutional building construction employers in Colorado

Alert subscribers get notified of each newly cited employer in Colorado the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.