OSHA SearchOSHA records by employer

Burke Brands, LLC: OSHA inspections and violations

Miami, Florida · Coffee and Tea Manufacturing · NAICS 311920

1inspections
13citation items
$18,034current penalties
Jul 9, 2019last inspection

OSHA has inspected Burke Brands, LLC once in Florida.

The inspection began on Jul 9, 2019 on a referral, in Miami.

That inspection ended with 13 citation items: 10 serious and 3 other-than-serious.

Penalties were first proposed at $25,763 and now stand at $18,034, 30% lower after settlements or reviews.

Electrical wiring methods comes up most often in these citations: 3 items under 1910.305.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $4,875, and Burke Brands, LLC averages $18,034 (1 cited inspection).

Burke Brands, LLC: OSHA citation items per year, 2019 to 2019
Citation items per year, by inspection date.

Florida · latest 90 days of OSHA records

326employers cited

Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Florida

Checking a subcontractor, a client or your own company? Watch Burke Brands, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344142161 OPENED JUL 9, 2019Closed

Referral · Partial · Safety · 25 employees at the site · Closed Jul 30, 2020

521 Ne 189th Street, Miami, FL 33179 · Coffee and Tea Manufacturing · OSHA's record · Phone and website on Google Maps

Incident on Jul 9, 2019: Employee incurs fractures in air dryer explosion

At 8:15 a.m. on July 9, 2019, an employee and his coworkers were asked to put trays of coffee beans that had been soaked with bourbon into the Sinton Electrical Air Dryer, Model XTDC-101-8A, to dry the beans at 180 degrees. It was reported that the dryer was making a "clicking" noise while being tested day prior to the accident. After 15 minutes of being used to dry the coffee beans, the dryer exploded. The employee was standing about 10 feet away from the dryer when it exploded. The employee was hospitalized to treat multiple fractures.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.147(c)(1) · Lockout/tagout
Serious$3,789$2,652Jan 6, 2020Final
Citation 1, item 2
29 CFR 1910.151(c) · First aid and eyewash
Serious$2,273$1,591Jan 6, 2020Final
Citation 1, item 3
29 CFR 1910.212(b) · Machine guarding
Serious$3,031$2,122Jan 6, 2020Final
Citation 1, item 4a
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Serious$3,789$2,652Jan 6, 2020Final
Citation 1, item 4b
29 CFR 1910.219(e)(3)(i) · Belts, pulleys and power-transmission parts
Serious$0$0Jan 6, 2020Final
Citation 1, item 5a
29 CFR 1910.303(b)(1)(viii) · Electrical equipment, general requirements
Serious$5,304$3,713Jan 6, 2020Final
Citation 1, item 5b
29 CFR 1910.304(f)(1)(i) · Grounding and circuit protection
Serious$0$0Jan 6, 2020Final
Citation 1, item 6a
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$2,273$1,591Jan 6, 2020Final
Citation 1, item 6b
29 CFR 1910.1200(h) · Hazard communication
Serious$0$0Jan 6, 2020Final
Citation 1, item 7
OSH Act Section 5(a)(1) · General Duty Clause
Serious$5,304$3,713Jan 6, 2020Final
Citation 2, item 1
29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods
Other-than-serious$0$0Jan 6, 2020Final
Citation 2, item 2
29 CFR 1910.305(g)(1)(iv)(a) · Electrical wiring methods
Other-than-serious$0$0Jan 6, 2020Final
Citation 2, item 3
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Other-than-serious$0$0Jan 6, 2020Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1910.1200(h)

(h) Post-mortem data: Increased incidence and/or severity of post-mortem findings may be indicative of maternal toxicity. This can include gross or microscopic pathological findings or organ weight data, including absolute organ weight, organ-to-body weight ratio, or organ-to-brain weight ratio. When supported by findings of adverse histopathological effects in the affected organ(s), the observation of a significant change in the average weight of suspected target organ(s) of treated dams (mothers), compared to those in the control group, may be considered evidence of maternal toxicity.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(1)

(c) General—(1) Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, start up or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source, and rendered inoperative.

29 CFR 1910.151 · First aid and eyewash

29 CFR 1910.212 · Machine guarding

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods

OSH Act Section 5 · General Duty Clause

Other coffee and tea manufacturing employers in Florida

Alert subscribers get notified of each newly cited employer in Florida the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.