Burkes Mechanical, Inc.: OSHA inspections and violations
Pennington, Alabama · Electrical Contractors and Other Wiring Installation Contractors · NAICS 238210
11inspections
10citation items
$30,050current penalties
Mar 4, 2020last inspection
OSHA has inspected Burkes Mechanical, Inc. 11 times in Alabama since 2002.
The latest one began on Mar 4, 2020 on a referral, in Monroeville.
Those inspections ended with 10 citation items: 8 serious and 2 other-than-serious.
Penalties were first proposed at $51,358 and now stand at $30,050, 41% lower after settlements or reviews.
Lockout/tagout comes up most often in these citations: 4 items under 1910.147.
How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Burkes Mechanical, Inc. averages $5,500 (2 cited inspections).
4 inspections on this page followed a fatal incident.
Burkes Mechanical, Inc. also files yearly injury logs with OSHA, summarized below.
It reported 4 severe injuries to OSHA since 2015.
Citation items per year, by inspection date.
Alabama · latest 90 days of OSHA records
99employers cited
2 of them in the same industry
Get notified the morning OSHA posts each new citation in Alabama: the employer, the site address, the rules broken and the penalty.
Incident on Feb 27, 2020: Employee suffers burns when sprayed by hot water/condensate
At 9:45 a.m. on February 27, 2020, Employee #1 was working for a plumbing/HVAC contractor. Employee #1 was changing gaskets on a valve that contained water of ~150-200 deg F. Employee #1 opened the valve seal and he was sprayed with hot water. Employee #1 received 1st and 2nd degree burns to his back and legs. Employee #1 was hospitalized.
Incident on Feb 7, 2006 (fatal): Employee falls from unguarded elevated platform and dies
Employee #1, a welder/crane operator, was operating a Broderson IC-200 mobile cr ane, attempting to lift and position a 31 ft 6 in. piece of 6 in. pipe through a maze of existing pipes running different directions at various elevations. He w as working with two coworkers, a helper/fitter and a fire watchman. During the l ift, the lead end of the pipe was offset to form an 11 ft U-shape to fit under a n existing pipe that crossed at the same elevation. When the U-shape end got stu ck between pipes, Coworker #1 climbed up onto an elevated 12-ft 6-in. by 9-ft 6- in. platform. The floor of the platform was about 3 ft below the stuck end and a bout 1 ft from the guardrails. Coworker #1 loosened the pipe with his hands, as Employee #1 remained in the crane. Employee #1 instructed Coworker #2 to apply p ressure against the trailing end, keeping it pushed against the crane to prevent kick out. Employee #1 then climbed onto the platform to assist. Both Employee # 1 and Coworker #1 wore a harness and lanyard and were tied off once they got ont o the platform. The elevated platform had a 5 ft diameter unguarded hole in the floor from when a LVHC gas scrubber tank was removed by the host company in 2002 . After the pipe was freed, Coworker #1 moved out of the way, so Employee #1 cou ld get down. Employee #1 unhooked his lanyard, turned around, and stepped forwar d, falling through the hole 12 ft 6 in. to the concrete surface below. Employee #1 was transported to the hospital, where he died two hours later.
Incident on Jan 16, 2002 (fatal): Two emplolyees died from breathing hydrogen sulfide
On January 16, 2002, two employees were killed and eight others were hospitalize d due to an unexpected release of hydrogen sulfide. (The eight hospitalized empl oyees were not listed on injury lines on the original form.)
No citations from this inspection.
Injury and illness logs
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2025, the Brent site logged 4 recordable injuries or illnesses among about 424 workers: 0.9 per 100 full-time workers, against a median of 1.8 for its industry. Those cases cost 46 days away from work.
Site and year
Workers
Cases
Days-away cases
Rate
Industry median
BM1
Brent · 2025
424
4
1
0.9
1.8
BM3
Demopolis · 2025
38
2
0
5.0
1.8
BM9
Pine Hill · 2025
20
1
0
4.9
1.8
BM2
Tuscaloosa · 2021
63
1
0
1.5
1.8
Brent site
Brent · 2019
857
14
5
1.6
1.8
BM10
Tuscaloosa · 2019
15
1
0
6.3
1.8
BM11
Tuscaloosa · 2019
10
1
0
10.0
1.8
BM Phifer
Tuscaloosa · 2018
43
3
2
6.6
1.8
Included with any plan: 21 more yearly logs from these sites, back to 2016, with each site's average rate over its latest three years. Already a subscriber? Sign in.
Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 4 reports on file.
Feb 27, 2020, Monroeville: Hospitalization · second degree heat (thermal) burns · multiple body parts, n.e.c.
An employee was changing gaskets on a valve that contained condensate. When the employee opened the pipe/valve, he was sprayed with hot water and sustained first and second degree burns to the back and legs.
Sep 9, 2019, Brent: Hospitalization · third or fourth degree heat (thermal) burns · hand(s), unspecified
A maintenance employee had just tightened a bolt. A second employee then put a wrench on it to check it. As the second employee was applying pressure to the wrench, a valve which controls the flow from the degreaser to the washer opened slightly. The injured employee was sprayed by 200-degree stock. He sustained third degree burns to both hands and second degree burns to his back.
Mar 1, 2019, Brent: Hospitalization · fractures · thigh(s)
A driver was stepping down from the back of a flatbed trailer, missed the step (DOT bumper) and fell to the ground fracturing his right upper leg.
An employee was unloading equipment at a storage facility. A 2" x 6" x 20' steel bar rolled onto the employee's left-hand pinky finger, crushing it between the bar and trailer. The first digit of the finger was surgically amputated.
The rules behind these citations
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
(4) Energy control procedure. (i) Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.
29 CFR 1910.147(c)(7)(i)
(7) Training and communication. (i) The employer shall provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees. The training shall include the following:
29 CFR 1910.147(f)(2)(i)
(2) Check the work area to ensure that all employees have been safely positioned or removed from the area.
Alert subscribers get notified of each newly cited employer in Alabama the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.