OSHA SearchOSHA records by employer

C&L Auto Body Inc: OSHA inspections and violations

Englewood, Colorado · Automotive Body, Paint, and Interior Repair and Maintenance · NAICS 811121

1inspections
3citation items
$1,366current penalties
May 19, 2023last inspection

OSHA has inspected C&L Auto Body Inc once in Colorado.

The inspection began on May 19, 2023 as a planned inspection, in Englewood.

That inspection ended with 3 citation items: 1 serious and 2 other-than-serious.

Penalties were first proposed at $2,277 and now stand at $1,366, 40% lower after settlements or reviews.

How that compares: the median penalty per cited inspection for repair and personal services employers since 2015 is $1,200, and C&L Auto Body Inc averages $1,366 (1 cited inspection).

C&L Auto Body Inc: OSHA citation items per year, 2023 to 2023
Citation items per year, by inspection date.

Colorado · latest 90 days of OSHA records

142employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Colorado: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Colorado

Checking a subcontractor, a client or your own company? Watch C&L Auto Body Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346714819 OPENED MAY 19, 2023Closed

Planned · Complete · Health · 15 employees at the site · Closed Aug 31, 2023

1864 W. Dartmouth Ave., Englewood, CO 80110 · Automotive Body, Paint, and Interior Repair and Maintenance · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.107(b)(9) · Spray painting and finishing
Serious$2,277$1,366Aug 14, 2023Final
Citation 2, item 1
29 CFR 1910.157(e)(3) · Portable fire extinguishers
Other-than-serious$0$0Aug 14, 2023Final
Citation 2, item 2
29 CFR 1910.1200(f)(6)(ii) · Hazard communication
Other-than-serious$0$0Aug 14, 2023Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(b)(9)

(9) Cleaning. Spray booths shall be so installed that all portions are readily accessible for cleaning. A clear space of not less than 3 feet on all sides shall be kept free from storage or combustible construction.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(f)(6)(ii)

(ii) Product identifier and words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals, and which, in conjunction with the other information immediately available to employees under the hazard communication program, will provide employees with the specific information regarding the physical and health hazards of the hazardous chemical.

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.157(e)(3)

(3) The employer shall assure that portable fire extinguishers are subjected to an annual maintenance check. Stored pressure extinguishers do not require an internal examination. The employer shall record the annual maintenance date and retain this record for one year after the last entry or the life of the shell, whichever is less. The record shall be available to the Assistant Secretary upon request.