Inspection 345742332 OPENED JAN 25, 2022Closed
19242 St. Rt. 576, Pioneer, OH 43554 · Recyclable Material Merchant Wholesalers · OSHA's record · Phone and website on Google Maps
Incident on Jan 21, 2022: Employee burns chest when propane tank leak ignites
On January 21, 2022, an employee was attempting to shut off the electrical power at an electrical panel as liquid propane was spraying from a 500-gallon propane tank located indoors. The propane ignited due to a spark from a nearby electrical box. A coworker had removed a draw valve on the tank in order to replace the valve. When the employee removed the valve, liquid propane began spraying out of the tank. The employee was burned on his chest and required hospitalization.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.132(d)(1) · Personal protective equipment, general requirements |
Serious | $5,801 | $2,901 | Jun 29, 2022 | Final |
| Citation 1, item 2 29 CFR 1910.178(l)(1)(ii) · Forklifts and other powered industrial trucks |
Serious | $5,801 | $2,901 | Jun 29, 2022 | Final |
| Citation 1, item 3 29 CFR 1910.307(c) · Hazardous (classified) locations |
Serious | $5,801 | $2,901 | Jun 29, 2022 | Final |
| Citation 1, item 4a 29 CFR 1910.1200(e)(1) · Hazard communication |
Serious | $5,801 | $2,901 | Jun 29, 2022 | Final |
| Citation 1, item 4b 29 CFR 1910.1200(g)(8) · Hazard communication |
Serious | $0 | $0 | Jun 29, 2022 | Final |
| Citation 1, item 4c 29 CFR 1910.1200(h)(1) · Hazard communication |
Serious | $0 | $0 | Jun 29, 2022 | Final |
| Citation 2, item 1 29 CFR 1904.29(b)(3) · Injury and illness log |
Other-than-serious | $829 | $413 | Jun 29, 2022 | Final |