OSHA SearchOSHA records by employer

C J Construction Inc: OSHA inspections and violations

Muncie, Indiana · Masonry Contractors · NAICS 238140

2inspections
14citation items
$4,350current penalties
Jun 21, 2016last inspection

Since 1986, OSHA inspectors have visited C J Construction Inc in Indiana 2 times.

The most recent inspection opened on Jun 21, 2016 as part of a related case, in Indianapolis and is still open.

In all, OSHA issued 14 citation items: 7 serious and 7 other-than-serious.

The penalties, $4,350 in total, stand where OSHA first set them.

The rule cited most here is 1926.500 (scope, application, and definitions applicable to this subpart), 2 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. C J Construction Inc averages $4,350 across 1 cited inspection.

C J Construction Inc: OSHA citation items per year, 1986 to 2016
Citation items per year, by inspection date.

Indiana · latest 90 days of OSHA records

78employers cited

Get notified the morning OSHA posts each new citation in Indiana: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Indiana

Checking a subcontractor, a client or your own company? Watch C J Construction Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341569036 OPENED JUN 21, 2016Open

Unprogrammed related · Partial · Safety · 6 employees at the site · Open

718 E Georgia St, Indianapolis, IN 46202 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$450$450Jul 15, 2016Final
Citation 1, item 1b
29 CFR 1926.20(b)(1) · Construction safety programs
Serious$0$0Jul 15, 2016Final
Citation 1, item 2
29 CFR 1926.20(b)(2) · Construction safety programs
Serious$450$450Jul 15, 2016Final
Citation 1, item 3
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$1,500$1,500Jul 15, 2016Final
Citation 1, item 4a
29 CFR 1926.454(a) · Scaffold training
Serious$450$450Jul 15, 2016Final
Citation 1, item 4b
29 CFR 1926.454(b) · Scaffold training
Serious$0$0Jul 15, 2016Final
Citation 1, item 5
29 CFR 1926.1053(b)(22) · Ladders in construction
Serious$1,500$1,500Jul 15, 2016Final

Inspection 102009289 OPENED FEB 11, 1986Closed

Planned · Complete · Safety · 7 employees at the site · Closed Jan 29, 1990

Lake Condo 3601 Lakeview Drive, Muncie, IN 47304 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.50(d)(1) · Medical services and first aid
Other-than-serious$0$0Feb 20, 1986Closed
Citation 1, item 2
29 CFR 1926.50(f) · Medical services and first aid
Other-than-serious$0$0Feb 20, 1986Closed
Citation 1, item 3
29 CFR 1926.150(c)(1)(iv) · Fire protection
Other-than-serious$0$0Feb 20, 1986Closed
Citation 1, item 4
29 CFR 1926.450(a)(2) · Scope, application and definitions applicable to this subpart
Other-than-serious$0$0Feb 20, 1986Closed
Citation 1, item 5
29 CFR 1926.450(b)(2) · Scope, application and definitions applicable to this subpart
Other-than-serious$0$0Feb 20, 1986Closed
Citation 1, item 6
29 CFR 1926.500(d)(1) · Scope, application, and definitions applicable to this subpart
Other-than-serious$0$0Feb 20, 1986Closed
Citation 1, item 7
29 CFR 1926.500(c)(1)(ii) · Scope, application, and definitions applicable to this subpart
Other-than-serious$0$0Feb 20, 1986Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(22)

(22) An employee shall not carry any object or load that could cause the employee to lose balance and fall.

29 CFR 1926.150 · Fire protection

29 CFR 1926.150(c)(1)(iv)

(iv) One or more fire extinguishers, rated not less than 2A, shall be provided on each floor. In multistory buildings, at least one fire extinguisher shall be located adjacent to stairway.

29 CFR 1926.20 · Construction safety programs

29 CFR 1926.450 · Scope, application and definitions applicable to this subpart

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.454 · Scaffold training

29 CFR 1926.50 · Medical services and first aid

29 CFR 1926.500 · Scope, application, and definitions applicable to this subpart

Other masonry contractors employers in Indiana

Alert subscribers get notified of each newly cited employer in Indiana the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.