C-Plex Inc.: OSHA inspections and violations

Lexington, South Carolina · All Other Plastics Product Manufacturing · NAICS 326199

7inspections
20citation items
$915current penalties
Dec 13, 2017last inspection

C-Plex Inc. has 7 OSHA inspections on record in South Carolina, the first in 1997.

OSHA's last visit started on Dec 13, 2017 as a planned inspection, in Lexington.

Across those inspections OSHA issued 20 citation items: 14 serious and 6 other-than-serious.

OSHA proposed $2,725 in penalties. After settlements and reviews the total is $915, down 66%.

Most often, OSHA cited 1910.212, machine guarding (5 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $4,500. C-Plex Inc. averages $0 over 1 cited inspection in that time.

C-Plex Inc.: OSHA citation items per year, 1997 to 2017
Citation items per year, by inspection date.

Want to know if OSHA cites C-Plex Inc. again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 342834140 OPENED DEC 13, 2017Closed

Planned · Complete · Health · 5 employees at the site · Closed Jun 12, 2018

520 Two Notch Road, Lexington, SC 29073 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(1) · Machine guarding
Serious$100$0Apr 5, 2018Final

Inspection 317010734 OPENED OCT 22, 2013Closed

Referral · Partial · Health · 14 employees at the site · Closed Nov 4, 2013

520 Two Notch Road, Lexington, SC 29073 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 317009462 OPENED SEP 10, 2013Closed

Planned · Complete · Safety · 9 employees at the site · Closed Jan 24, 2014

520 Two Notch Road, Lexington, SC 29073 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.132(a) · Personal protective equipment, general requirements
Serious$500$250Oct 30, 2013Closed
Citation 1, item 2
29 CFR 1910.178(k)(1) · Forklifts and other powered industrial trucks
Serious$250$125Oct 30, 2013Closed
Citation 1, item 3
29 CFR 1910.212(a)(1) · Machine guarding
Serious$375$188Oct 30, 2013Closed
Citation 1, item 4
29 CFR 1910.242(b) · Hand and power tools
Serious$150$75Oct 30, 2013Closed
Citation 2, item 1
29 CFR 1910.178(l)(4)(iii) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Oct 30, 2013Closed
Citation 2, item 2
29 CFR 1910.304(a)(2) · Grounding and circuit protection
Other-than-serious$375$188Oct 30, 2013Closed

Inspection 315188722 OPENED FEB 16, 2011Closed

Planned · Complete · Health · 6 employees at the site · Closed May 6, 2011

520 Two Notch Road, Lexington, SC 29073 · Plastics Pipe and Pipe Fitting Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.106(d)(3)(ii) · Flammable liquids
Serious$225$0Mar 28, 2011Final

Inspection 310971205 OPENED JUL 10, 2007Closed

Planned · Complete · Health · 7 employees at the site · Closed Aug 31, 2007

520 Two Notch Road, Lexington, SC 29073 · Plastics Pipe and Pipe Fitting Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.1052(d)(2) · Methylene chloride
Other-than-serious$0$0Aug 22, 2007Closed

Inspection 306836222 OPENED JAN 6, 2004Closed

Planned · Complete · Safety · 8 employees at the site · Closed Oct 6, 2004

520 Two Notch Road, Lexington, SC 29073 · Unlaminated Plastics Profile Shape Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.147(c)(6)(i) · Lockout/tagout
Serious$300$0Jan 20, 2004Closed
Citation 1, item 2
29 CFR 1910.212(a)(1) · Machine guarding
Serious$225$0Jan 20, 2004Closed
Citation 1, item 3
29 CFR 1910.304(f)(5)(vc)(8) · Grounding and circuit protection
Serious$0$0Jan 20, 2004Closed
Citation 2, item 1
29 CFR 1910.213(b)(3) · Woodworking machinery
Other-than-serious$0$0Jan 20, 2004Closed

Inspection 301749263 OPENED JUL 10, 1997Closed

Complaint · Complete · Safety · 18 employees at the site · Closed Sep 10, 1997

520 Two Notch Road, Lexington, SC 29073 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(1) · Machine guarding
Serious$0$0Aug 1, 1997Closed
Citation 1, item 4
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Serious$0$0Aug 1, 1997Closed
Citation 1, item 5
29 CFR 1910.304(f)(5)(vc)(1) · Grounding and circuit protection
Other-than-serious$225$0Aug 1, 1997Closed
Citation 1, item 6
29 CFR 1910.304(f)(5)(vc)(7) · Grounding and circuit protection
Serious$0$0Aug 1, 1997Closed
Citation 1, item 7a
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$0$90Aug 1, 1997Closed
Citation 1, item 7b
29 CFR 1910.213(h)(1) · Woodworking machinery
Serious$0$0Aug 1, 1997Closed
Citation 2, item 1
29 CFR 1910.178(p)(1) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Aug 1, 1997Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1052 · Methylene chloride

29 CFR 1910.1052(d)(2)

(2) Initial determination. Each employer whose employees are exposed to MC shall perform initial exposure monitoring to determine each affected employee's exposure, except under the following conditions:

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(d)(3)(ii)

(ii) Fire resistance. Storage cabinets shall be designed and constructed to limit the internal temperature to not more than 325 °F. when subjected to a 10-minute fire test using the standard time-temperature curve as set forth in Standard Methods of Fire Tests of Building Construction and Materials, NFPA 251-1969, which is incorporated by reference as specified in § 1910.6. All joints and seams shall remain tight and the door shall remain securely closed during the fire test. Cabinets shall be labeled in conspicuous lettering, “Flammable—Keep Fire Away.”

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.132(a)

(a) Application. Protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, shall be provided, used, and maintained in a sanitary and reliable condition wherever it is necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation or physical contact.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.212 · Machine guarding

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.242 · Hand and power tools

29 CFR 1910.304 · Grounding and circuit protection

Other all other plastics product manufacturing employers in South Carolina