Inspection 345121404 OPENED JAN 28, 2021Closed
2845 Armentrout Drive, Concord, NC 28025 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Concord, North Carolina · All Other Plastics Product Manufacturing · NAICS 326199
OSHA has inspected Cabarrus Plastics, Inc. 10 times in North Carolina since 1990.
The latest one began on Jan 28, 2021 to follow up on an earlier case, in Concord.
Those inspections ended with 37 citation items: 13 serious and 24 other-than-serious.
Penalties were first proposed at $24,276 and now stand at $16,476, 32% lower after settlements or reviews.
Lockout/tagout comes up most often in these citations: 9 items under 1910.147.
How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $4,500, and Cabarrus Plastics, Inc. averages $5,067 (3 cited inspections).
Cabarrus Plastics, Inc. also files yearly injury logs with OSHA, summarized below.
North Carolina · latest 90 days of OSHA records
230employers cited
5 of them in the same industry
Get notified the morning OSHA posts each new citation in North Carolina: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in North Carolina
Checking a subcontractor, a client or your own company? Watch Cabarrus Plastics, Inc. and get notified the morning OSHA posts a new citation for it.
Watch this company2845 Armentrout Drive, Concord, NC 28025 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
2845 Armentrout Drive, Concord, NC 28025 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1910.147(c)(4)(i) · Lockout/tagout |
Serious | $7,000 | $5,000 | Apr 20, 2020 | Final |
| Citation 1, item 1b 29 CFR 1910.147(c)(6)(i) · Lockout/tagout |
Serious | $0 | $0 | Apr 20, 2020 | Final |
| Citation 1, item 1c 29 CFR 1910.147(c)(4)(ii)(a) · Lockout/tagout |
Serious | $0 | $0 | Apr 20, 2020 | Final |
| Citation 1, item 2 29 CFR 1910.178(l)(4)(iii) · Forklifts and other powered industrial trucks |
Serious | $7,000 | $5,000 | Apr 20, 2020 | Final |
2845 Armentrout Drive, Concord, NC 28025 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
2845 Armentrout Drive, Concord, NC 28025 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
2845 Armentrout Drive, Concord, NC 28025 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.22(a)(2) · Walking-working surfaces |
Serious | $2,700 | $1,000 | Feb 9, 2017 | Final |
2845 Armentrout Dr, Concord, NC 28025 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.212(a)(3)(ii) · Machine guarding |
Serious | $6,300 | $4,200 | Apr 1, 2015 | Closed |
2845 Armentrout Dr., Concord, NC 28025 · Unlaminated Plastics Profile Shape Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1910.132(d)(2) · Personal protective equipment, general requirements |
Other-than-serious | $0 | $0 | May 23, 2006 | Closed |
| Citation 1, item 1b 29 CFR 1910.132(d)(4) · Personal protective equipment, general requirements |
Other-than-serious | $0 | $0 | May 23, 2006 | Closed |
2845 Armentrout Dr., Concord, NC 28025 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1910.147(d)(4)(i) · Lockout/tagout |
Serious | $525 | $525 | Sep 16, 2003 | Closed |
| Citation 1, item 1b 29 CFR 1910.147(d)(6) · Lockout/tagout |
Serious | $0 | $0 | Sep 16, 2003 | Closed |
| Citation 1, item 1c 29 CFR 1910.147(c)(4)(ii) · Lockout/tagout |
Serious | $0 | $0 | Sep 16, 2003 | Closed |
| Citation 1, item 1d 29 CFR 1910.147(c)(6)(i) · Lockout/tagout |
Serious | $0 | $0 | Sep 16, 2003 | Closed |
| Citation 1, item 2 29 CFR 1910.212(a)(1) · Machine guarding |
Serious | $450 | $450 | Sep 16, 2003 | Closed |
| Citation 2, item 1 29 CFR 7F0102 |
Other-than-serious | $0 | $0 | Sep 16, 2003 | Closed |
| Citation 2, item 2 29 CFR 7F0102 |
Other-than-serious | $0 | $0 | Sep 16, 2003 | Closed |
| Citation 2, item 3 29 CFR 1910.95(c)(1) · Noise |
Other-than-serious | $0 | $0 | Sep 16, 2003 | Closed |
| Citation 2, item 4 29 CFR 1910.106(e)(6)(ii) · Flammable liquids |
Other-than-serious | $0 | $0 | Sep 16, 2003 | Closed |
| Citation 2, item 5 29 CFR 1910.147(c)(5)(ii) · Lockout/tagout |
Other-than-serious | $0 | $0 | Sep 16, 2003 | Closed |
| Citation 2, item 6 29 CFR 1910.147(c)(7)(iv) · Lockout/tagout |
Other-than-serious | $0 | $0 | Sep 16, 2003 | Closed |
| Citation 2, item 7 29 CFR 1910.157(g)(1) · Portable fire extinguishers |
Other-than-serious | $0 | $0 | Sep 16, 2003 | Closed |
| Citation 2, item 8 29 CFR 1910.179(j)(2)(iii) · Overhead and gantry cranes |
Other-than-serious | $0 | $0 | Sep 16, 2003 | Closed |
| Citation 2, item 9 29 CFR 1910.179(m)(1) · Overhead and gantry cranes |
Other-than-serious | $0 | $0 | Sep 16, 2003 | Closed |
| Citation 2, item 10 29 CFR 1910.184(e)(3)(i) · Slings |
Other-than-serious | $0 | $0 | Sep 16, 2003 | Closed |
| Citation 2, item 11 29 CFR 1910.303(b)(2) · Electrical equipment, general requirements |
Other-than-serious | $0 | $0 | Sep 16, 2003 | Closed |
| Citation 2, item 12 29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods |
Other-than-serious | $0 | $0 | Sep 16, 2003 | Closed |
| Citation 2, item 13 29 CFR 1910.334(d) · Using electrical equipment |
Other-than-serious | $0 | $0 | Sep 16, 2003 | Closed |
| Citation 2, item 14 29 CFR 1910.1200(f)(5)(i) · Hazard communication |
Other-than-serious | $0 | $0 | Sep 16, 2003 | Closed |
| Citation 2, item 15 29 CFR 1910.1200(h)(1) · Hazard communication |
Other-than-serious | $0 | $0 | Sep 16, 2003 | Closed |
2845 Armentrout Dr., Concord, NC 28025 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes |
Serious | $188 | $188 | Jan 14, 1999 | Closed |
| Citation 1, item 2 29 CFR 1910.212(a)(1) · Machine guarding |
Serious | $113 | $113 | Jan 14, 1999 | Closed |
| Citation 2, item 1 29 CFR 1910.24(b) · Fixed industrial stairs |
Other-than-serious | $0 | $0 | Jan 14, 1999 | Closed |
| Citation 2, item 2 29 CFR 1910.37(k)(2) · Exit routes |
Other-than-serious | $0 | $0 | Jan 14, 1999 | Closed |
| Citation 2, item 3 29 CFR 1910.242(a) · Hand and power tools |
Other-than-serious | $0 | $0 | Jan 14, 1999 | Closed |
| Citation 2, item 4 29 CFR 1910.253(b)(2)(ii) · Gas welding and cutting |
Other-than-serious | $0 | $0 | Jan 14, 1999 | Closed |
| Citation 2, item 5 29 CFR 1910.253(b)(4)(iii) · Gas welding and cutting |
Other-than-serious | $0 | $0 | Jan 14, 1999 | Closed |
| Citation 2, item 6 29 CFR 1910.303(f) · Electrical equipment, general requirements |
Other-than-serious | $0 | $0 | Jan 14, 1999 | Closed |
| Citation 2, item 7 29 CFR 1910.303(g)(1)(ii) · Electrical equipment, general requirements |
Other-than-serious | $0 | $0 | Jan 14, 1999 | Closed |
384 Faggart Ave., Concord, NC 28025 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2020, the Concord site logged 4 recordable injuries or illnesses among about 125 workers: 3.9 per 100 full-time workers, against a median of 2.6 for its industry. Those cases cost 2 days away from work.
| Site and year | Workers | Cases | Days-away cases | Rate | Industry median |
|---|---|---|---|---|---|
| Cabarrus Plastics, Inc Concord · 2020 | 125 | 4 | 1 | 3.9 | 2.6 |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.106(e)(6)(ii)
(ii) Grounding. Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall not be dispensed into containers unless the nozzle and container are electrically interconnected. Where the metallic floorplate on which the container stands while filling is electrically connected to the fill stem or where the fill stem is bonded to the container during filling operations by means of a bond wire, the provisions of this section shall be deemed to have been complied with.
29 CFR 1910.1200(f)(5)(i)
(5) Transportation. (i) Chemical manufacturers, importers, or distributors shall ensure that each container of hazardous chemicals leaving the workplace is labeled, tagged, or marked in accordance with this section in a manner which does not conflict with the requirements of the Hazardous Materials Transportation Act (49 U.S.C. 5101 et seq.) and regulations issued under that Act by the Department of Transportation (49 CFR subtitle B).
29 CFR 1910.1200(h)(1)
(h) Employee information and training. (1) Employers shall provide employees with effective information and training on hazardous chemicals in their work area at the time of their initial assignment, and whenever a new chemical hazard the employees have not previously been trained about is introduced into their work area. Information and training may be designed to cover categories of hazards (e.g., flammability, carcinogenicity) or specific chemicals. Chemical-specific information must always be available through labels and safety data sheets.
Alert subscribers get notified of each newly cited employer in North Carolina the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.