OSHA SearchOSHA records by employer

Cable Electrical Services, Inc.: OSHA inspections and violations

Orlando, Florida · Electrical Contractors and Other Wiring Installation Contractors · NAICS 238210

6inspections
6citation items
$15,512current penalties
Jul 20, 2023last inspection

OSHA has inspected Cable Electrical Services, Inc. 6 times in Florida since 2001.

The latest one began on Jul 20, 2023 after a complaint, in Apopka.

Those inspections ended with 6 citation items: 4 serious and 2 other-than-serious.

Penalties were first proposed at $22,541 and now stand at $15,512, 31% lower after settlements or reviews.

Aerial lifts comes up most often in these citations: 2 items under 1926.453.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,079, and Cable Electrical Services, Inc. averages $5,037 (2 cited inspections).

It reported 1 severe injury to OSHA since 2015.

Cable Electrical Services, Inc.: OSHA citation items per year, 2001 to 2023
Citation items per year, by inspection date.

Want to know if OSHA cites Cable Electrical Services, Inc. again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 346849573 OPENED JUL 20, 2023Closed

Complaint · Partial · Safety · 2 employees at the site · Closed Sep 29, 2023

2302 Ocoee-apopka Road, Apopka, FL 32703 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 344902556 OPENED AUG 27, 2020Closed

Unprogrammed related · Complete · Safety · 10 employees at the site · Closed Feb 24, 2021

Hancock Rd, Minneola, FL 34715 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.453(b)(2)(v) · Aerial lifts
Serious$9,557$5,734Jan 28, 2021Final
Citation 2, item 1
29 CFR 1926.100(a) · Hard hats in construction
Other-than-serious$767$460Jan 28, 2021Final

Inspection 342710233 OPENED OCT 17, 2017Closed

Referral · Partial · Safety · 6 employees at the site · Closed May 9, 2018

10107 Ancora Circle, Orlando, FL 32821 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Incident on Oct 6, 2017: Employee is struck by falling pulley and incurs head injurie

At 2:15 p.m. on October 6, 2017, Employee #1, employed by an electrical contractor, was engaged in electrical installation work at a multiemployer construction project. He was pulling wire through a conduit when the pulley slipped and fell, striking his head. Emergency services were called, and Employee #1 was transported to the hospital. He was admitted and treated for head injuries.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
OSH Act Section 5(a)(1) · General Duty Clause
Serious$6,467$3,880Mar 28, 2018Final

Inspection 339543837 OPENED JAN 9, 2014Closed

Planned · Complete · Safety · 5 employees at the site · Closed Mar 24, 2015

4201 Commons Drive West, Destin, FL 32541 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.453(b)(2)(v) · Aerial lifts
Serious$4,500$4,500Mar 3, 2014Final

Inspection 312174667 OPENED APR 17, 2008Closed

Planned · Partial · Safety · 23 employees at the site · Closed Aug 8, 2008

Arbor Glen - 4850 N. State Road 33, Lakeland, FL 33805 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$1,250$938Jul 16, 2008Closed

Inspection 304443427 OPENED APR 25, 2001Closed

Unprogrammed other · Complete · Safety · 17 employees at the site · Closed May 31, 2001

1705 Grande Pointe Blvd, Orlando, FL 32839 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.404(f)(6) · Ground-fault protection on job sites
Other-than-serious$0$0May 10, 2001Closed

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.

Oct 6, 2017, Orlando: Hospitalization · intracranial injuries, unspecified · brain

An employee was pulling wire using a pulley when the pulley gave way and fell 10 feet, striking the top of the employee's head. He was hospitalized.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.100 · Hard hats in construction

29 CFR 1926.100(a)

(a) Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets.

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.404(f)(6)

(6) Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent and continuous.

29 CFR 1926.453 · Aerial lifts

29 CFR 1926.453(b)(2)(v)

(v) A body belt shall be worn and a lanyard attached to the boom or basket when working from an aerial lift.

29 CFR 1926.501 · Fall protection in construction

OSH Act Section 5 · General Duty Clause

Other electrical contractors and other wiring installation contractors employers in Florida

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.