OSHA SearchOSHA records by employer

Callaway Farms Manufacturing LLC: OSHA inspections and violations

Washington, Georgia · Sawmills · NAICS 321113

4inspections
41citation items
$32,632current penalties
Sep 19, 2016last inspection

Callaway Farms Manufacturing LLC has 4 OSHA inspections on record in Georgia, the first in 2009.

OSHA's last visit started on Sep 19, 2016 to follow up on an earlier case, in Washington.

Across those inspections OSHA issued 41 citation items: 36 serious, 2 repeat and 3 other-than-serious.

OSHA proposed $56,492 in penalties. After settlements and reviews the total is $32,632, down 42%.

Most often, OSHA cited 1910.219, belts, pulleys and power-transmission parts (8 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $4,500. Callaway Farms Manufacturing LLC averages $7,211 over 3 cited inspections in that time.

Callaway Farms Manufacturing LLC: OSHA citation items per year, 2009 to 2016
Citation items per year, by inspection date.

Georgia · latest 90 days of OSHA records

157employers cited

3 of them in the same industry

Get notified the morning OSHA posts each new citation in Georgia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Georgia

Checking a subcontractor, a client or your own company? Watch Callaway Farms Manufacturing LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341781656 OPENED SEP 19, 2016Closed

Follow-up · Partial · Health · 25 employees at the site · Closed Jul 15, 2019

371 Harris Rd, Washington, GA 30673 · Sawmills · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1b
29 CFR 1910.24(b) · Fixed industrial stairs
Serious$0$2,000Oct 19, 2016Final
Citation 2, item 2
29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes
Repeat$12,471$2,500Oct 19, 2016Final
Citation 2, item 3 Repeat$12,471$2,500Oct 19, 2016Final

Inspection 341056406 OPENED NOV 13, 2015Closed

Complaint · Complete · Health · 30 employees at the site · Closed Sep 28, 2018

371 Harris Rd, Washington, GA 30673 · Sawmills · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.22(a)(1) · General requirements
Serious$2,625$1,575Dec 8, 2015Final
Citation 1, item 2 Serious$2,625$1,575Dec 8, 2015Final
Citation 1, item 3 Serious$2,625$1,566Dec 8, 2015Final
Citation 2, item 1
29 CFR 1910.146(c)(5)(ii)(c) · Permit-required confined spaces
Other-than-serious$0$0Dec 8, 2015Final
Citation 3, item 1a
29 CFR 1903.19(c)(3) · Proving cited hazards were fixed
Other-than-serious$700$700Aug 4, 2016Final
Citation 3, item 1b
29 CFR 1903.19(e)(1) · Proving cited hazards were fixed
Other-than-serious$0$0Aug 4, 2016Final

Inspection 341065381 OPENED NOV 13, 2015Closed

Complaint · Complete · Safety · 24 employees at the site · Closed Dec 13, 2016

371 Harris Rd, Washington, GA 30673 · Sawmills · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
OSH Act Section 5(a)(1) · General Duty Clause
Serious$900$540Dec 8, 2015Final
Citation 1, item 2
29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes
Serious$1,275$765Dec 8, 2015Final
Citation 1, item 3
29 CFR 1910.24(e) · Fixed industrial stairs
Serious$1,200$492Dec 8, 2015Final
Citation 1, item 4
29 CFR 1910.37(a)(3) · Exit routes
Serious$1,275$765Dec 8, 2015Final
Citation 1, item 5
29 CFR 1910.37(b)(6) · Exit routes
Serious$1,275$765Dec 8, 2015Final
Citation 1, item 6
29 CFR 1910.147(c)(5)(ii) · Lockout/tagout
Serious$900$540Dec 8, 2015Final
Citation 1, item 7
29 CFR 1910.147(c)(6)(i)(b) · Lockout/tagout
Serious$2,800$1,659Dec 8, 2015Final
Citation 1, item 8
29 CFR 1910.219(c)(4)(i) · Belts, pulleys and power-transmission parts
Serious$900$540Dec 8, 2015Final
Citation 1, item 9a
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Serious$1,275$765Dec 8, 2015Final
Citation 1, item 9b
29 CFR 1910.219(e)(1)(i) · Belts, pulleys and power-transmission parts
Serious$0$0Dec 8, 2015Final
Citation 1, item 10
29 CFR 1910.219(f)(3) · Belts, pulleys and power-transmission parts
Serious$1,275$765Dec 8, 2015Final
Citation 1, item 11
29 CFR 1910.253(b)(2)(iv) · Gas welding and cutting
Serious$900$540Dec 8, 2015Final
Citation 1, item 12
29 CFR 1910.253(b)(4)(iii) · Gas welding and cutting
Serious$900$540Dec 8, 2015Final
Citation 1, item 13a
29 CFR 1910.303(b)(1)(iv) · Electrical equipment, general requirements
Serious$900$540Dec 8, 2015Final
Citation 1, item 13b
29 CFR 1910.305(g)(1)(iv)(a) · Electrical wiring methods
Serious$0$0Dec 8, 2015Final

Inspection 312527682 OPENED JUL 20, 2009Closed

Complaint · Partial · Health · 21 employees at the site · Closed Aug 3, 2011

371 Harris Road, Washington, GA 30673 · Reconstituted Wood Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 8b
29 CFR 1910.147(c)(5)(iib) · Lockout/tagout
Serious$0$0Nov 17, 2009Final
Citation 1, item 21
29 CFR 1910.22(a)(1) · General requirements
Serious$1,200$1,200Nov 17, 2009Final
Citation 1, item 22 Serious$1,500$1,500Nov 17, 2009Final
Citation 1, item 23
29 CFR 1910.146(g)(1) · Permit-required confined spaces
Serious$1,500$1,100Nov 17, 2009Final
Citation 1, item 24a Serious$0$3,000Nov 17, 2009Final
Citation 1, item 24b Serious$0$0Nov 17, 2009Final
Citation 1, item 25
29 CFR 1910.307(b) · Hazardous (classified) locations
Serious$3,000$0Nov 17, 2009Final
Citation 1, item 26a
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$0$3,000Nov 17, 2009Final
Citation 1, item 26b
29 CFR 1910.147(c)(7)(i) · Lockout/tagout
Serious$0$0Nov 17, 2009Final
Citation 1, item 27a
29 CFR 1910.1030(c)(1)(i) · Bloodborne pathogens
Serious$0$1,200Nov 17, 2009Final
Citation 1, item 27b
29 CFR 1910.1030(f)(1)(iia) · Bloodborne pathogens
Serious$0$0Nov 17, 2009Final
Citation 1, item 27c
29 CFR 1910.1030(g)(2)(iib) · Bloodborne pathogens
Serious$0$0Nov 17, 2009Final
Citation 2, item 1a
29 CFR 1910.212(a)(1) · Machine guarding
Serious$0$0Nov 17, 2009Final
Citation 2, item 1b
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Serious$0$0Nov 17, 2009Final
Citation 2, item 1c
29 CFR 1910.219(c)(4)(i) · Belts, pulleys and power-transmission parts
Serious$0$0Nov 17, 2009Final
Citation 2, item 1d
29 CFR 1910.219(e)(3)(i) · Belts, pulleys and power-transmission parts
Serious$0$0Nov 17, 2009Final
Citation 2, item 1e
29 CFR 1910.219(f)(3) · Belts, pulleys and power-transmission parts
Serious$0$0Nov 17, 2009Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1903.19 · Proving cited hazards were fixed

29 CFR 1903.19(c)(3)

(3) The employer's certification that abatement is complete must include, for each cited violation, in addition to the information required by paragraph (h) of this section, the date and method of abatement and a statement that affected employees and their representatives have been informed of the abatement.

29 CFR 1903.19(e)(1)

(e) Abatement plans. (1) The Agency may require an employer to submit an abatement plan for each cited violation (except an other-than-serious violation) when the time permitted for abatement is more than 90 calendar days. If an abatement plan is required, the citation must so indicate.

29 CFR 1910.1030 · Bloodborne pathogens

29 CFR 1910.1030(c)(1)(i)

(c) Exposure control—(1) Exposure Control Plan. (i) Each employer having an employee(s) with occupational exposure as defined by paragraph (b) of this section shall establish a written Exposure Control Plan designed to eliminate or minimize employee exposure.

29 CFR 1910.146 · Permit-required confined spaces

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.212 · Machine guarding

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.22 · General requirements

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.24 · Fixed industrial stairs

29 CFR 1910.253 · Gas welding and cutting

29 CFR 1910.265 · Sawmills

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.307 · Hazardous (classified) locations

29 CFR 1910.37 · Exit routes

29 CFR 1910.95 · Noise

OSH Act Section 5 · General Duty Clause

Other sawmills employers in Georgia

Alert subscribers get notified of each newly cited employer in Georgia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.