OSHA SearchOSHA records by employer

Camfil USA, Inc.: OSHA inspections and violations

Washington, North Carolina · Ventilation, Heating, Air-Conditioning, and Commercial Refrigeration Equipment Manufacturing · NAICS 333411

1inspections
3citation items
$2,250current penalties
Apr 25, 2016last inspection

OSHA has inspected Camfil USA, Inc. once in North Carolina.

The inspection began on Apr 25, 2016 on a referral, in Washington.

That inspection ended with 3 citation items: 2 serious and 1 other-than-serious.

Penalties were first proposed at $2,250 and still stand at $2,250.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Camfil USA, Inc. averages $2,250 (1 cited inspection).

Camfil USA, Inc. also files yearly injury logs with OSHA, summarized below.

Camfil USA, Inc.: OSHA citation items per year, 2016 to 2016
Citation items per year, by inspection date.

North Carolina · latest 90 days of OSHA records

228employers cited

Get notified the morning OSHA posts each new citation in North Carolina: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in North Carolina

Checking a subcontractor, a client or your own company? Watch Camfil USA, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Company-wide record

OSHA records show Camfil USA, Inc. at 4 sites in 4 states. Together they've had 10 inspections and $60,028 in current penalties.

We match records by employer name and industry, so these sites are likely the same company, not certainly. Franchises and subsidiaries can file under one name.

Included with any plan: the site-by-site record for all 4 sites, with repeat and willful violations and citations per year for the whole company. Already a subscriber? Sign in.

See plans

Inspection history

Inspection 341431419 OPENED APR 25, 2016Closed

Referral · Partial · Safety · 128 employees at the site · Closed Jul 13, 2016

200 Creekside Drive, Washington, NC 27889 · Ventilation, Heating, Air-Conditioning, and Commercial Refrigeration Equipment Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$1,500$1,500Jun 10, 2016Final
Citation 1, item 2
29 CFR 1910.213(i)(1) · Woodworking machinery
Serious$750$750Jun 10, 2016Final
Citation 2, item 1
29 CFR 1910.22(d)(1) · General requirements
Other-than-serious$0$0Jun 10, 2016Final

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2021, the Washington site logged 1 recordable injury or illness among about 141 workers: 0.6 per 100 full-time workers, against a median of 2.4 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Camfil USA, Inc.
Washington · 2021
141 100.62.4

Included with any plan: 3 more yearly logs from these sites, back to 2018, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.212 · Machine guarding

29 CFR 1910.212(a)(3)(ii)

(ii) The point of operation of machines whose operation exposes an employee to injury, shall be guarded. The guarding device shall be in conformity with any appropriate standards therefor, or, in the absence of applicable specific standards, shall be so designed and constructed as to prevent the operator from having any part of his body in the danger zone during the operating cycle.

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.213(i)(1)

(i) Bandsaws and band resaws. (1) All portions of the saw blade shall be enclosed or guarded, except for the working portion of the blade between the bottom of the guide rolls and the table. Bandsaw wheels shall be fully encased. The outside periphery of the enclosure shall be solid. The front and back of the band wheels shall be either enclosed by solid material or by wire mesh or perforated metal. Such mesh or perforated metal shall be not less than 0.037 inch (U.S. Gage No. 20), and the openings shall be not greater than three-eighths inch. Solid material used for this purpose shall be of an equivalent strength and firmness. The guard for the portion of the blade between the sliding guide and the upper-saw-wheel guard shall protect the saw blade at the front and outer side. This portion of the guard shall be self-adjusting to raise and lower with the guide. The upper-wheel guard shall

29 CFR 1910.22 · General requirements

Other ventilation, heating, air-conditioning, and commercial refrigeration equipment manufacturing employers in North Carolina

Alert subscribers get notified of each newly cited employer in North Carolina the morning it is posted. See the alert plans.