OSHA SearchOSHA records by employer

Camouflage Masonry: OSHA inspections and violations

Stillwater, Oklahoma · Masonry Contractors · NAICS 238140

1inspections
4citation items
$5,760current penalties
May 3, 2018last inspection

OSHA inspectors have visited Camouflage Masonry in Oklahoma one time.

It opened on May 3, 2018 as a planned inspection, in Stillwater.

In all, OSHA issued 4 citation items: 4 serious.

The proposed penalties came to $9,608; today they stand at $5,760, 40% less.

The rule cited most here is 1926.451 (scaffolds, general requirements), 3 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Camouflage Masonry averages $5,760 across 1 cited inspection.

Camouflage Masonry: OSHA citation items per year, 2018 to 2018
Citation items per year, by inspection date.

Oklahoma · latest 90 days of OSHA records

53employers cited

Get notified the morning OSHA posts each new citation in Oklahoma: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Oklahoma

Checking a subcontractor, a client or your own company? Watch Camouflage Masonry and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343136271 OPENED MAY 3, 2018Closed

Planned · Partial · Safety · 16 employees at the site · Closed Sep 18, 2018

501 S. Ramsey, Stillwater, OK 74075 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.178(l)(1)(i) · Forklifts and other powered industrial trucks
Serious$2,956$1,770Jul 17, 2018Final
Citation 1, item 2
29 CFR 1926.451(c)(1)(ii) · Scaffolds, general requirements
Serious$3,696$2,220Jul 17, 2018Final
Citation 1, item 3a
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$2,956$1,770Jul 17, 2018Final
Citation 1, item 3b
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$0$0Jul 17, 2018Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.178(l)(1)(i)

(l) Operator training. (1) Safe operation. (i) The employer shall ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l).

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(c)(1)(ii)

(ii) Guys, ties, and braces shall be installed according to the scaffold manufacturer's recommendations or at the closest horizontal member to the 4:1 height and be repeated vertically at locations of horizontal members every 20 feet (6.1 m) or less thereafter for scaffolds 3 feet (0.91 m) wide or less, and every 26 feet (7.9 m) or less thereafter for scaffolds greater than 3 feet (0.91 m) wide. The top guy, tie or brace of completed scaffolds shall be placed no further than the 4:1 height from the top. Such guys, ties and braces shall be installed at each end of the scaffold and at horizontal intervals not to exceed 30 feet (9.1 m) (measured from one end [not both] towards the other).

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

Other masonry contractors employers in Oklahoma

Alert subscribers get notified of each newly cited employer in Oklahoma the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.