5inspections
34citation items
$20,765current penalties
Jan 24, 2024last inspection

Canada DRY Potomac Corporation has 5 OSHA inspections on record in Virginia, the first in 1993.

OSHA's last visit started on Jan 24, 2024 on a referral, in Virginia Beach, and the case has not closed yet.

Across those inspections OSHA issued 34 citation items: 27 serious and 7 other-than-serious.

OSHA proposed $24,025 in penalties. After settlements and reviews the total is $20,765, down 14%.

Most often, OSHA cited 1910.303, electrical equipment, general requirements (5 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $4,860. Canada DRY Potomac Corporation averages $15,375 over 1 cited inspection in that time.

Canada DRY Potomac Corporation: OSHA citation items per year, 1993 to 2024
Citation items per year, by inspection date.

Virginia · latest 90 days of OSHA records

251employers cited

Get notified the morning OSHA posts each new citation in Virginia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Virginia

Checking a subcontractor, a client or your own company? Watch Canada DRY Potomac Corporation and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347229296 OPENED JAN 24, 2024Open

Referral · Partial · Safety · 103 employees at the site · Open

1400 Air Rail Avenue, Virginia Beach, VA 23455 · General Warehousing and Storage · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.178(l)(1)(ii) · Forklifts and other powered industrial trucks
Serious$15,375$15,375May 1, 2024Contested

Inspection 312735665 OPENED OCT 30, 2008Closed

Planned · Complete · Health · 68 employees at the site · Closed Jan 6, 2009

3100 North Hopkins Road, Richmond, VA 23224 · Other Grocery and Related Products Merchant Wholesalers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.303(g)(1)(i) · Electrical equipment, general requirements
Serious$525$315Dec 3, 2008Final
Citation 2, item 1
29 CFR 1910.37(b)(5) · Exit routes
Other-than-serious$0$0Dec 3, 2008Final
Citation 2, item 2
29 CFR 1910.157(c)(1) · Portable fire extinguishers
Other-than-serious$0$0Dec 3, 2008Final

Inspection 310360201 OPENED AUG 11, 2006Closed

Planned · Complete · Safety · 65 employees at the site · Closed Sep 12, 2006

3100 North Hopkins Road, Richmond, VA 23224 · Soft Drink Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.106(d)(2)(i) · Flammable liquids
Serious$1,125$675Aug 22, 2006Closed
Citation 2, item 1
29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes
Other-than-serious$0$0Aug 22, 2006Closed

Inspection 303903520 OPENED NOV 2, 2000Closed

Planned · No inspection · Safety · Closed Nov 2, 2000

3100 North Hopkins Road, Richmond, VA 23224 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 123658593 OPENED JAN 13, 1993Closed

Planned · Complete · Safety · 52 employees at the site · Closed Dec 22, 1993

1805 Summitt Ave., Richmond, VA 23230 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.37(k)(2) · Exit routes
Serious$525$325Mar 30, 1993Final
Citation 1, item 2a
29 CFR 1910.147(c)(1) · Lockout/tagout
Serious$875$575Mar 30, 1993Final
Citation 1, item 2b
29 CFR 1910.147(c)(7)(i) · Lockout/tagout
Serious$0$0Mar 30, 1993Final
Citation 1, item 3a
29 CFR 1910.157(c)(1) · Portable fire extinguishers
Serious$875$575Mar 30, 1993Final
Citation 1, item 3b
29 CFR 1910.157(c)(4) · Portable fire extinguishers
Serious$0$0Mar 30, 1993Final
Citation 1, item 3c
29 CFR 1910.157(g)(1) · Portable fire extinguishers
Serious$0$0Mar 30, 1993Final
Citation 1, item 3d
29 CFR 1910.157(g)(2) · Portable fire extinguishers
Serious$0$0Mar 30, 1993Final
Citation 1, item 4
29 CFR 1910.176(c) · Material storage and aisles
Serious$525$325Mar 30, 1993Final
Citation 1, item 5a
29 CFR 1910.178(m)(5)(i) · Forklifts and other powered industrial trucks
Serious$525$325Mar 30, 1993Final
Citation 1, item 5b
29 CFR 1910.178(p)(1) · Forklifts and other powered industrial trucks
Serious$0$0Mar 30, 1993Final
Citation 1, item 6
29 CFR 1910.212(b) · Machine guarding
Serious$525$325Mar 30, 1993Final
Citation 1, item 7a
29 CFR 1910.215(a)(4) · Grinders and abrasive wheels
Serious$525$325Mar 30, 1993Final
Citation 1, item 7b
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Serious$0$0Mar 30, 1993Final
Citation 1, item 8a
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Serious$1,225$725Mar 30, 1993Final
Citation 1, item 8b
29 CFR 1910.219(e)(1)(i) · Belts, pulleys and power-transmission parts
Serious$0$0Mar 30, 1993Final
Citation 1, item 8c
29 CFR 1910.219(e)(3)(i) · Belts, pulleys and power-transmission parts
Serious$0$0Mar 30, 1993Final
Citation 1, item 8d
29 CFR 1910.219(f)(3) · Belts, pulleys and power-transmission parts
Serious$0$0Mar 30, 1993Final
Citation 1, item 9a
29 CFR 1910.253(b)(2)(ii) · Gas welding and cutting
Serious$525$325Mar 30, 1993Final
Citation 1, item 9b
29 CFR 1910.253(b)(2)(iv) · Gas welding and cutting
Serious$0$0Mar 30, 1993Final
Citation 1, item 9c
29 CFR 1910.253(b)(4)(iii) · Gas welding and cutting
Serious$0$0Mar 30, 1993Final
Citation 1, item 10a
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Serious$875$575Mar 30, 1993Final
Citation 1, item 10b
29 CFR 1910.303(e) · Electrical equipment, general requirements
Serious$0$0Mar 30, 1993Final
Citation 1, item 10c
29 CFR 1910.303(f) · Electrical equipment, general requirements
Serious$0$0Mar 30, 1993Final
Citation 1, item 10d
29 CFR 1910.303(g)(1)(ii) · Electrical equipment, general requirements
Serious$0$0Mar 30, 1993Final
Citation 2, item 1
29 CFR 1910.24(d) · Fixed industrial stairs
Other-than-serious$0$0Mar 30, 1993Final
Citation 2, item 2
29 CFR 1910.106(d)(2)(i) · Flammable liquids
Other-than-serious$0$0Mar 30, 1993Final
Citation 2, item 3
29 CFR 1910.106(d)(4)(v) · Flammable liquids
Other-than-serious$0$0Mar 30, 1993Final
Citation 2, item 5 Other-than-serious$0$0Mar 30, 1993Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(d)(2)(i)

(2) Design, construction, and capacity of containers—(i) General. Only approved containers and portable tanks shall be used. Metal containers and portable tanks meeting the requirements of and containing products authorized by chapter I, title 49 of the Code of Federal Regulations (regulations issued by the Hazardous Materials Regulations Board, Department of Transportation), shall be deemed to be acceptable.

29 CFR 1910.106(d)(4)(v)

(v) Storage in inside storage rooms. In every inside storage room there shall be maintained one clear aisle at least 3 feet wide. Containers over 30 gallons capacity shall not be stacked one upon the other. Dispensing shall be by approved pump or self-closing faucet only.

29 CFR 1910.141 · Sanitation

29 CFR 1910.141(d)(2)(iii)

(iii) Hand soap or similar cleansing agents shall be provided.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.176 · Material storage and aisles

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.212 · Machine guarding

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.24 · Fixed industrial stairs

29 CFR 1910.253 · Gas welding and cutting

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.37 · Exit routes

Other soft drink manufacturing employers in Virginia

Alert subscribers get notified of each newly cited employer in Virginia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.