OSHA SearchOSHA records by employer

Canton Masonry, Inc: OSHA inspections and violations

Weymouth, Massachusetts · Masonry Contractors · NAICS 238140

11inspections
25citation items
$18,195current penalties
Oct 2, 2020last inspection

Since 1985, OSHA inspectors have visited Canton Masonry, Inc in Massachusetts 11 times.

The most recent inspection opened on Oct 2, 2020 as part of a related case, in Marshfield.

In all, OSHA issued 25 citation items: 21 serious and 4 other-than-serious.

The proposed penalties came to $32,977; today they stand at $18,195, 45% less.

The rule cited most here is 1926.451 (scaffolds, general requirements), 15 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Canton Masonry, Inc averages $5,000 across 1 cited inspection.

Canton Masonry, Inc: OSHA citation items per year, 1985 to 2020
Citation items per year, by inspection date.

Massachusetts · latest 90 days of OSHA records

249employers cited

5 of them in the same industry

Get notified the morning OSHA posts each new citation in Massachusetts: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Massachusetts

Checking a subcontractor, a client or your own company? Watch Canton Masonry, Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344963459 OPENED OCT 2, 2020Closed

Unprogrammed related · Partial · Safety · 15 employees at the site · Closed May 17, 2021

3 Progress Way, Marshfield, MA 02050 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 2
29 CFR 1926.706(b) · Requirements for masonry construction
Serious$6,007$5,000Mar 25, 2021Final

Inspection 343617148 OPENED NOV 7, 2018Closed

Unprogrammed other · Partial · Safety · 20 employees at the site · Closed Nov 8, 2018

10 Front Street, Weymouth, MA 02188 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 309572972 OPENED DEC 27, 2006Closed

Planned · Partial · Safety · 10 employees at the site · Closed May 24, 2007

Old Page Street, Stoughton, MA 02072 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.178(l) · Forklifts and other powered industrial trucks
Serious$750$375Apr 9, 2007Closed
Citation 1, item 1b
29 CFR 1910.178(l)(6) · Forklifts and other powered industrial trucks
Serious$0$0Apr 9, 2007Closed
Citation 1, item 2
29 CFR 1926.451(c)(2)(iv) · Scaffolds, general requirements
Serious$2,000$1,000Apr 9, 2007Closed

Inspection 306033408 OPENED OCT 31, 2002Closed

Planned · Partial · Safety · 9 employees at the site · Closed Apr 10, 2003

84 Washington Street, Woburn, MA 01801 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$4,000$2,000Feb 12, 2003Closed

Inspection 302921077 OPENED MAY 9, 2000Closed

Unprogrammed other · Complete · Safety · 5 employees at the site · Closed Jun 28, 2000

Route 3a & Crocker Road, Cohasset, MA 02025 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.25(a) · Housekeeping
Serious$600$300May 23, 2000Closed
Citation 1, item 2
29 CFR 1926.451(a)(1) · Scaffolds, general requirements
Serious$1,000$500May 23, 2000Closed
Citation 1, item 3
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$800$400May 23, 2000Closed
Citation 1, item 4
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$800$400May 23, 2000Closed
Citation 2, item 1
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$1,200$600May 23, 2000Closed

Inspection 300344686 OPENED NOV 7, 1997Closed

Referral · Complete · Safety · 10 employees at the site · Closed Mar 2, 1998

389 Common Street, Braintree, MA 02184 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.21(b)(2) · Construction safety training
Serious$1,050$605Feb 2, 1998Closed
Citation 1, item 2
29 CFR 1926.451(c)(2)(ii) · Scaffolds, general requirements
Serious$1,500$860Feb 2, 1998Closed
Citation 1, item 3
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$1,500$860Feb 2, 1998Closed
Citation 1, item 4
29 CFR 1926.451(f)(4) · Scaffolds, general requirements
Serious$1,050$605Feb 2, 1998Closed
Citation 1, item 5
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Serious$1,050$605Feb 2, 1998Closed
Citation 1, item 6
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$1,500$860Feb 2, 1998Closed
Citation 1, item 7
29 CFR 1926.701(b) · Concrete and Masonry Construction: general requirements
Serious$1,050$605Feb 2, 1998Closed

Inspection 109134155 OPENED MAY 27, 1994Closed

Referral · Partial · Safety · 13 employees at the site · Closed Aug 2, 1994

128 Eastern Avenue, Chelsea, MA 02150 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.21(b)(2) · Construction safety training
Other-than-serious$2,000$0Jun 14, 1994Closed
Citation 1, item 1b
29 CFR 1926.451(a)(13) · Scaffolds, general requirements
Other-than-serious$0$0Jun 14, 1994Closed
Citation 1, item 2
29 CFR 1926.451(d)(10) · Scaffolds, general requirements
Serious$2,000$1,000Jun 14, 1994Closed

Inspection 107323503 OPENED NOV 22, 1993Closed

Planned · Complete · Safety · 7 employees at the site · Closed May 20, 1994

1160 Broadway, Saugus, MA 01906 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(a)(13) · Scaffolds, general requirements
Serious$1,500$750Mar 8, 1994Closed
Citation 1, item 2
29 CFR 1926.451(d)(10) · Scaffolds, general requirements
Serious$1,500$750Mar 8, 1994Closed
3 older inspections

Inspection 100455252 OPENED NOV 13, 1986Closed

Unprogrammed other · Complete · Safety · 14 employees at the site · Closed Nov 13, 1986

800 Hingham Street, Rockland, MA 02370 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 101037448 OPENED JUN 9, 1986Closed

Unprogrammed other · Complete · Safety · 12 employees at the site · Closed Aug 14, 1986

194-195 Libby Industrial Park, Weymouth, MA 02190 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(d)(10) · Scaffolds, general requirements
Serious$120$120Jul 7, 1986Closed
Citation 2, item 1
29 CFR 1926.450(a)(1) · Scope, application and definitions applicable to this subpart
Other-than-serious$0$0Jul 7, 1986Closed

Inspection 100471614 OPENED DEC 3, 1985Closed

Unprogrammed other · Complete · Safety · 7 employees at the site · Closed Jun 9, 1986

291 Pond Street, Avon, MA 02322 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.601(b)(4) · Motor vehicles
Other-than-serious$0$0Dec 20, 1985Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.178(l)(6)

(6) Certification. The employer shall certify that each operator has been trained and evaluated as required by this paragraph (l). The certification shall include the name of the operator, the date of the training, the date of the evaluation, and the identity of the person(s) performing the training or evaluation.

29 CFR 1926.21 · Construction safety training

29 CFR 1926.21(b)(2)

(2) The employer shall instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his work environment to control or eliminate any hazards or other exposure to illness or injury.

29 CFR 1926.25 · Housekeeping

29 CFR 1926.25(a)

(a) During the course of construction, alteration, or repairs, form and scrap lumber with protruding nails, and all other debris, shall be kept cleared from work areas, passageways, and stairs, in and around buildings or other structures.

29 CFR 1926.450 · Scope, application and definitions applicable to this subpart

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.601 · Motor vehicles

29 CFR 1926.701 · Concrete and Masonry Construction: general requirements

29 CFR 1926.706 · Requirements for masonry construction

Other masonry contractors employers in Massachusetts

Alert subscribers get notified of each newly cited employer in Massachusetts the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.