Cap Masonry: OSHA inspections and violations

Glenn Heights, Texas · Masonry Contractors · NAICS 238140

1inspections
3citation items
$9,678current penalties
Oct 4, 2023last inspection

OSHA has inspected Cap Masonry once in Texas.

The inspection began on Oct 4, 2023 as a planned inspection, in Glenn Heights; the case is still open.

That inspection ended with 3 citation items: 3 serious.

Penalties were first proposed at $9,678 and still stand at $9,678.

Scaffolds, general requirements comes up most often in these citations: 3 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,078, and Cap Masonry averages $9,678 (1 cited inspection).

Cap Masonry: OSHA citation items per year, 2023 to 2023
Citation items per year, by inspection date.

Want to know if OSHA cites Cap Masonry again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 347012759 OPENED OCT 4, 2023Open

Planned · Partial · Safety · 3 employees at the site · Open

2308 Frio River, Glenn Heights, TX 75154 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(1)(i) · Scaffolds, general requirements
Serious$4,148$4,148Jan 24, 2024Final
Citation 1, item 2
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$2,765$2,765Jan 24, 2024Final
Citation 1, item 3
29 CFR 1926.451(c)(2)(ii) · Scaffolds, general requirements
Serious$2,765$2,765Jan 24, 2024Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)(i)

(i) Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) shall be installed so that the space between adjacent units and the space between the platform and the uprights is no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary (for example, to fit around uprights when side brackets are used to extend the width of the platform).

29 CFR 1926.451(c)(2)

(2) Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation.

29 CFR 1926.451(c)(2)(ii)

(ii) Unstable objects shall not be used to support scaffolds or platform units.