OSHA SearchOSHA records by employer

Care Products, Inc.: OSHA inspections and violations

Mcallen, Texas · Cut and Sew Apparel Manufacturing · NAICS 315299

2inspections
24citation items
$64,162current penalties
Feb 28, 2018last inspection

Since 1991, OSHA inspectors have visited Care Products, Inc. in Texas 2 times.

The most recent inspection opened on Feb 28, 2018 as a planned inspection, in Mcallen.

In all, OSHA issued 24 citation items: 21 serious and 3 other-than-serious.

The proposed penalties came to $65,762; today they stand at $64,162, 2% less.

The rule cited most here is 1910.305 (electrical wiring methods), 3 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $4,875 penalty. Care Products, Inc. averages $61,762 across 1 cited inspection.

Care Products, Inc.: OSHA citation items per year, 1991 to 2018
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

391employers cited

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Care Products, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342996196 OPENED FEB 28, 2018Closed

Planned · Complete · Safety · 18 employees at the site · Closed Oct 29, 2020

10701 N. Ware Road, Mcallen, TX 78504 · Cut and Sew Apparel Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.22(a)(1) · Walking-working surfaces
Serious$2,956$2,956Aug 24, 2018Final
Citation 1, item 2
29 CFR 1910.39(c)(3) · Fire prevention plans
Serious$2,956$2,956Aug 24, 2018Final
Citation 1, item 3
29 CFR 1910.133(a)(2) · Eye and face protection
Serious$3,696$3,696Aug 24, 2018Final
Citation 1, item 4
29 CFR 1910.147(d) · Lockout/tagout
Serious$5,174$5,174Aug 24, 2018Final
Citation 1, item 5
29 CFR 1910.178(l)(4)(i) · Forklifts and other powered industrial trucks
Serious$2,217$2,217Aug 24, 2018Final
Citation 1, item 6
29 CFR 1910.212(a)(1) · Machine guarding
Serious$4,434$4,434Aug 24, 2018Final
Citation 1, item 7
29 CFR 1910.212(b) · Machine guarding
Serious$3,696$3,696Aug 24, 2018Final
Citation 1, item 8
29 CFR 1910.213(a)(12) · Woodworking machinery
Serious$5,174$5,174Aug 24, 2018Final
Citation 1, item 9
29 CFR 1910.242(b) · Hand and power tools
Serious$5,174$5,174Aug 24, 2018Final
Citation 1, item 10
29 CFR 1910.243(d)(3)(iv) · Guarding of portable powered tools
Serious$4,434$4,434Aug 24, 2018Final
Citation 1, item 11
29 CFR 1910.303(b)(1)(i) · Electrical equipment, general requirements
Serious$3,696$3,696Aug 24, 2018Final
Citation 1, item 12
29 CFR 1910.303(b)(7)(iv) · Electrical equipment, general requirements
Serious$2,956$2,956Aug 24, 2018Final
Citation 1, item 13
29 CFR 1910.304(c)(4) · Grounding and circuit protection
Serious$3,696$3,696Aug 24, 2018Final
Citation 1, item 14
29 CFR 1910.305(g)(1)(iv)(b) · Electrical wiring methods
Serious$3,696$3,696Aug 24, 2018Final
Citation 1, item 15
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Serious$3,696$3,696Aug 24, 2018Final
Citation 1, item 16
29 CFR 1910.305(j)(2)(iv) · Electrical wiring methods
Serious$3,696$3,696Aug 24, 2018Final
Citation 2, item 1
29 CFR 1910.37(a)(4) · Exit routes
Other-than-serious$0$0Aug 24, 2018Final
Citation 2, item 2
29 CFR 1910.151(b) · First aid and eyewash
Other-than-serious$415$415Aug 24, 2018Final
Citation 2, item 3
29 CFR 1910.157(e)(3) · Portable fire extinguishers
Other-than-serious$0$0Aug 24, 2018Final

Inspection 100307701 OPENED AUG 28, 1991Closed

Planned · Complete · Safety · 30 employees at the site · Closed May 1, 1992

Rt. 7, Box 1000, Mcallen, TX 78504 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.157(c)(1) · Portable fire extinguishers
Serious$750$375Jan 16, 1992Closed
Citation 1, item 2
29 CFR 1910.157(e)(3) · Portable fire extinguishers
Serious$750$375Jan 16, 1992Closed
Citation 1, item 3
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$1,250$1,000Jan 16, 1992Closed
Citation 1, item 4a
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Serious$1,250$650Jan 16, 1992Closed
Citation 1, item 4b
29 CFR 1910.219(e)(1)(i) · Belts, pulleys and power-transmission parts
Serious$0$0Jan 16, 1992Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.133 · Eye and face protection

29 CFR 1910.133(a)(2)

(2) The employer shall ensure that each affected employee uses eye protection that provides side protection when there is a hazard from flying objects. Detachable side protectors (e.g. clip-on or slide-on side shields) meeting the pertinent requirements of this section are acceptable.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(d)

(d) Application of control. The established procedures for the application of energy control (the lockout or tagout procedures) shall cover the following elements and actions and shall be done in the following sequence:

29 CFR 1910.151 · First aid and eyewash

29 CFR 1910.151(b)

(b) In the absence of an infirmary, clinic, or hospital in near proximity to the workplace which is used for the treatment of all injured employees, a person or persons shall be adequately trained to render first aid. Adequate first aid supplies shall be readily available.

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.212 · Machine guarding

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.22 · Walking-working surfaces

29 CFR 1910.242 · Hand and power tools

29 CFR 1910.243 · Guarding of portable powered tools

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.37 · Exit routes

29 CFR 1910.39 · Fire prevention plans

Other cut and sew apparel manufacturing employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.