OSHA SearchOSHA records by employer

Caribbean Display & Contractor Inc.: OSHA inspections and violations

Bayamon, Puerto Rico · Industrial Building Construction · NAICS 236210

1inspections
3citation items
$2,082current penalties
Feb 26, 2021last inspection

Caribbean Display & Contractor Inc. has one OSHA inspection on record in Puerto Rico.

OSHA opened it on Feb 26, 2021 as a planned inspection, in Bayamon.

From that inspection OSHA issued 3 citation items: 3 serious.

OSHA proposed $2,975 in penalties. After settlements and reviews the total is $2,082, down 30%.

Most often, OSHA cited 1926.451, scaffolds, general requirements (2 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Caribbean Display & Contractor Inc. averages $2,082 over 1 cited inspection in that time.

Caribbean Display & Contractor Inc.: OSHA citation items per year, 2021 to 2021
Citation items per year, by inspection date.

Puerto Rico · latest 90 days of OSHA records

109employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Puerto Rico: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Puerto Rico

Checking a subcontractor, a client or your own company? Watch Caribbean Display & Contractor Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345169551 OPENED FEB 26, 2021Closed

Planned · Complete · Safety · 4 employees at the site · Closed Nov 3, 2021

Carr. #2 Caparra Esquina Jard?nes De Caparra, Bayamon, PR 00956 · Industrial Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$1,225$858May 27, 2021Final
Citation 1, item 2
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$525$368May 27, 2021Final
Citation 1, item 3
29 CFR 1926.452(c)(2) · Rules for each type of scaffold
Serious$1,225$858May 27, 2021Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)

(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.452(c)(2)

(2) Frames and panels shall be braced by cross, horizontal, or diagonal braces, or combination thereof, which secure vertical members together laterally. The cross braces shall be of such length as will automatically square and align vertical members so that the erected scaffold is always plumb, level, and square. All brace connections shall be secured.