Cascade Casework Corp: OSHA inspections and violations

Lebanon, Oregon · Wood Kitchen Cabinet and Countertop Manufacturing · NAICS 337110

4inspections
5citation items
$350current penalties
Jul 19, 2017last inspection

Cascade Casework Corp has 4 OSHA inspections on record in Oregon, the first in 2015.

OSHA's last visit started on Jul 19, 2017 as a planned inspection, in Springfield.

Across those inspections OSHA issued 5 citation items: 3 serious and 2 other-than-serious.

OSHA proposed $350 in penalties and the amount has not been reduced.

Most often, OSHA cited 1910.213, woodworking machinery (2 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Cascade Casework Corp averages $175 over 2 cited inspections in that time.

Cascade Casework Corp: OSHA citation items per year, 2015 to 2017
Citation items per year, by inspection date.

Want to know if OSHA cites Cascade Casework Corp again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 342488491 OPENED JUL 19, 2017Closed

Planned · Complete · Safety · 30 employees at the site · Closed Mar 26, 2019

326 Centennial Blvd, Springfield, OR 97477 · Wood Kitchen Cabinet and Countertop Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.213(c)(1) · Woodworking machinery
Serious$150$150Aug 10, 2017Final

Inspection 341867224 OPENED OCT 26, 2016Closed

Planned · No inspection · Health · Closed Oct 26, 2016

33431 Brewster Rd, Lebanon, OR 97355 · Wood Kitchen Cabinet and Countertop Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 341238335 OPENED FEB 8, 2016Closed

Planned · No inspection · Safety · Closed Feb 8, 2016

33431 Brewster Rd, Lebanon, OR 97355 · Wood Kitchen Cabinet and Countertop Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 340908763 OPENED JUL 31, 2015Closed

Planned · Complete · Safety · 8 employees at the site · Closed Jan 6, 2016

214 13th Ave Se, Albany, OR 97322 · Wood Kitchen Cabinet and Countertop Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.213(h)(1) · Woodworking machinery
Serious$100$100Sep 15, 2015Final
Citation 1, item 2
29 CFR 1910.178(l)(1)(ii) · Forklifts and other powered industrial trucks
Serious$100$100Sep 15, 2015Final
Citation 2, item 3
29 CFR OAR 437-001-0765(7)-3
Other-than-serious$0$0Sep 15, 2015Final
Citation 2, item 4
29 CFR OAR 437-002-0187(4)-2
Other-than-serious$0$0Sep 15, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.178(l)(1)(ii)

(ii) Prior to permitting an employee to operate a powered industrial truck (except for training purposes), the employer shall ensure that each operator has successfully completed the training required by this paragraph (l), except as permitted by paragraph (l)(5).

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.213(c)(1)

(c) Hand-fed ripsaws. (1) Each circular hand-fed ripsaw shall be guarded by a hood which shall completely enclose that portion of the saw above the table and that portion of the saw above the material being cut. The hood and mounting shall be arranged so that the hood will automatically adjust itself to the thickness of and remain in contact with the material being cut but it shall not offer any considerable resistance to insertion of material to saw or to passage of the material being sawed. The hood shall be made of adequate strength to resist blows and strains incidental to reasonable operation, adjusting, and handling, and shall be so designed as to protect the operator from flying splinters and broken saw teeth. It shall be made of material that is soft enough so that it will be unlikely to cause tooth breakage. The hood shall be so mounted as to insure that its operation will be po

29 CFR 1910.213(h)(1)

(h) Radial saws. (1) The upper hood shall completely enclose the upper portion of the blade down to a point that will include the end of the saw arbor. The upper hood shall be constructed in such a manner and of such material that it will protect the operator from flying splinters, broken saw teeth, etc., and will deflect sawdust away from the operator. The sides of the lower exposed portion of the blade shall be guarded to the full diameter of the blade by a device that will automatically adjust itself to the thickness of the stock and remain in contact with stock being cut to give maximum protection possible for the operation being performed.