OSHA SearchOSHA records by employer

Castle Brook Framing: OSHA inspections and violations

Elkhorn, Nebraska · Framing Contractors · NAICS 238130

1inspections
5citation items
$11,200current penalties
Jan 27, 2016last inspection

OSHA has inspected Castle Brook Framing once in Nebraska.

The inspection began on Jan 27, 2016 as a planned inspection, in Elkhorn.

That inspection ended with 5 citation items: 5 serious.

Penalties were first proposed at $11,200 and still stand at $11,200.

Scaffolds, general requirements comes up most often in these citations: 4 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Castle Brook Framing averages $11,200 (1 cited inspection).

Castle Brook Framing: OSHA citation items per year, 2016 to 2016
Citation items per year, by inspection date.

Nebraska · latest 90 days of OSHA records

36employers cited

3 of them in the same industry

Get notified the morning OSHA posts each new citation in Nebraska: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Nebraska

Checking a subcontractor, a client or your own company? Watch Castle Brook Framing and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341210649 OPENED JAN 27, 2016Closed

Planned · Partial · Safety · 4 employees at the site · Closed Sep 6, 2016

625 N. 189th Street, Elkhorn, NE 68022 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(2) · Scaffolds, general requirements
Serious$2,800$2,800Mar 18, 2016Final
Citation 1, item 2a
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$2,800$2,800Mar 18, 2016Final
Citation 1, item 2b
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Serious$0$0Mar 18, 2016Final
Citation 1, item 3
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$2,800$2,800Mar 18, 2016Final
Citation 1, item 4
29 CFR 1926.452(a)(4) · Rules for each type of scaffold
Serious$2,800$2,800Mar 18, 2016Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(2)

(2) Except as provided in paragraphs (b)(2)(i) and (b)(2)(ii) of this section, each scaffold platform and walkway shall be at least 18 inches (46 cm) wide.

29 CFR 1926.451(f)(3)

(3) Scaffolds and scaffold components shall be inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity.

29 CFR 1926.451(f)(7)

(7) Scaffolds shall be erected, moved, dismantled, or altered only under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration. Such activities shall be performed only by experienced and trained employees selected for such work by the competent person.

29 CFR 1926.452 · Rules for each type of scaffold

Other framing contractors employers in Nebraska

Alert subscribers get notified of each newly cited employer in Nebraska the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.