Inspection 348495037 OPENED SEP 9, 2025Closed
9401 85th Avenue North, Minneapolis, MN 55445 · Construction Machinery Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Brooklyn Park, Minnesota · Construction Machinery Manufacturing · NAICS 333120
Since 1991, OSHA inspectors have visited Caterpillar Paving Products Inc in Minnesota 10 times.
The most recent inspection opened on Sep 9, 2025 as a planned inspection, in Minneapolis.
In all, OSHA issued 28 citation items: 21 serious and 7 other-than-serious.
The proposed penalties came to $28,228; today they stand at $16,863, 40% less.
The rule cited most here is 1910.305 (electrical wiring methods), 4 times.
Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Caterpillar Paving Products Inc averages $1,185 across 2 cited inspections.
Minnesota · latest 90 days of OSHA records
371employers cited
Get notified the morning OSHA posts each new citation in Minnesota: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Minnesota
Checking a subcontractor, a client or your own company? Watch Caterpillar Paving Products Inc and get notified the morning OSHA posts a new citation for it.
Watch this company9401 85th Avenue North, Minneapolis, MN 55445 · Construction Machinery Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
9401 85th Avenue North, Minneapolis, MN 55445 · Construction Machinery Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.254(d)(9)(iii) · Arc welding and cutting |
Serious | $900 | $900 | Jul 14, 2021 | Final |
9401 85th Avenue North, Minneapolis, MN 55445 · Construction Machinery Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 | Serious | $1,400 | $980 | Aug 3, 2017 | Final |
| Citation 2, item 1 | Other-than-serious | $700 | $490 | Aug 3, 2017 | Final |
9401 85th Avenue North, Brooklyn Park, MN 55445 · Construction Machinery Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes |
Serious | $2,450 | $463 | Sep 7, 2010 | Final |
| Citation 1, item 3 29 CFR 1910.304(g)(5) · Grounding and circuit protection |
Serious | $1,750 | $324 | Sep 7, 2010 | Final |
| Citation 1, item 4 29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods |
Other-than-serious | $1,750 | $324 | Sep 7, 2010 | Final |
| Citation 2, item 1 29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods |
Other-than-serious | $350 | $65 | Sep 7, 2010 | Final |
2120 North Broadway, New Ulm, MN 56073 · Construction Machinery Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
9401 85th Avenue North, Brooklyn Park, MN 55445 · Construction Machinery Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.212(b) · Machine guarding |
Serious | $900 | $630 | Nov 22, 2006 | Closed |
| Citation 1, item 2 29 CFR 1910.303(b)(2) · Electrical equipment, general requirements |
Serious | $1,200 | $840 | Nov 22, 2006 | Closed |
| Citation 1, item 3 29 CFR 1910.305(b)(2) · Electrical wiring methods |
Serious | $900 | $630 | Nov 22, 2006 | Closed |
| Citation 1, item 4 | Serious | $1,200 | $840 | Nov 22, 2006 | Closed |
9401 85th Avenue North, Brooklyn Park, MN 55445 · Construction Machinery Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.29(a)(2)(ii) · Manually propelled mobile ladder stands and scaffolds (towers) |
Serious | $900 | $630 | Mar 12, 2003 | Closed |
| Citation 1, item 2 29 CFR 1910.110(e)(4)(iii) · Storage and handling of liquefied petroleum gases |
Serious | $1,200 | $840 | Mar 12, 2003 | Closed |
| Citation 1, item 3 29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods |
Serious | $900 | $630 | Mar 12, 2003 | Closed |
| Citation 1, item 4 | Serious | $900 | $630 | Mar 12, 2003 | Closed |
| Citation 1, item 5 | Serious | $1,200 | $840 | Mar 12, 2003 | Closed |
| Citation 2, item 1 29 CFR 1910.303(g)(1)(ii) · Electrical equipment, general requirements |
Other-than-serious | $300 | $210 | Mar 12, 2003 | Closed |
9401 85th Avenue North, Brooklyn Park, MN 55445 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
9401 85th Avenue North, Brooklyn Park, MN 55445 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.106(d)(4)(i) · Flammable liquids |
Serious | $1,050 | $735 | Feb 24, 2000 | Closed |
| Citation 1, item 2 29 CFR 1910.106(d)(4)(iv) · Flammable liquids |
Serious | $1,050 | $735 | Feb 24, 2000 | Closed |
| Citation 1, item 3 29 CFR 1910.178(l) · Forklifts and other powered industrial trucks |
Serious | $1,050 | $735 | Feb 24, 2000 | Closed |
| Citation 1, item 4 29 CFR 1910.212(a)(3)(ii) · Machine guarding |
Serious | $1,400 | $980 | Feb 24, 2000 | Closed |
| Citation 1, item 5 | Serious | $1,050 | $735 | Feb 24, 2000 | Closed |
| Citation 1, item 6 | Serious | $1,750 | $1,225 | Feb 24, 2000 | Closed |
| Citation 1, item 7 | Serious | $1,400 | $980 | Feb 24, 2000 | Closed |
| Citation 2, item 1 29 CFR 1910.147(e)(3) · Lockout/tagout |
Other-than-serious | $350 | $245 | Feb 24, 2000 | Closed |
9401 85th Avenue North, Brooklyn Park, MN 55445 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.212(a)(3)(ii) · Machine guarding |
Serious | $228 | $228 | Sep 4, 1991 | Closed |
| Citation 2, item 1 | Other-than-serious | $0 | $0 | Sep 4, 1991 | Closed |
| Citation 2, item 2 | Other-than-serious | $0 | $0 | Sep 4, 1991 | Closed |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.106(d)(4)(i)
(4) Design and construction of inside storage rooms—(i) Construction. Inside storage rooms shall be constructed to meet the required fire-resistive rating for their use. Such construction shall comply with the test specifications set forth in Standard Methods of Fire Tests of Building Construction and Materials, NFPA 251-1969. Where an automatic sprinkler system is provided, the system shall be designed and installed in an acceptable manner. Openings to other rooms or buildings shall be provided with noncombustible liquid-tight raised sills or ramps at least 4 inches in height, or the floor in the storage area shall be at least 4 inches below the surrounding floor. Openings shall be provided with approved self-closing fire doors. The room shall be liquid-tight where the walls join the floor. A permissible alternate to the sill or ramp is an open-grated trench inside of the room which dra
29 CFR 1910.106(d)(4)(iv)
(iv) Ventilation. Every inside storage room shall be provided with either a gravity or a mechanical exhaust ventilation system. Such system shall be designed to provide for a complete change of air within the room at least six times per hour. If a mechanical exhaust system is used, it shall be controlled by a switch located outside of the door. The ventilating equipment and any lighting fixtures shall be operated by the same switch. A pilot light shall be installed adjacent to the switch if Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), are dispensed within the room. Where gravity ventilation is provided, the fresh air intake, as well as the exhaust outlet from the room, shall be on the exterior of the building in which the room is located.
29 CFR 1910.110(e)(4)(iii)
(iii) Permanent and removable fuel containers shall be securely mounted to prevent jarring loose, slipping, or rotating, and the fastenings shall be designed and constructed to withstand static loading in any direction equal to twice the weight of the tank and attachments when filled with fuel using a safety factor of not less than four based on the ultimate strength of the material to be used. Field welding, when necessary, shall be made only on saddle plates, lugs or brackets, originally attached to the container by the tank manufacturer.
Alert subscribers get notified of each newly cited employer in Minnesota the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.