OSHA SearchOSHA records by employer

Caterpillar Precision Pin Products Group: OSHA inspections and violations

Sumter, South Carolina · Mechanical Power Transmission Equipment Manufacturing · NAICS 333613

4inspections
5citation items
$6,875current penalties
Jan 15, 2026last inspection

OSHA has inspected Caterpillar Precision Pin Products Group 4 times in South Carolina since 2000.

The latest one began on Jan 15, 2026 after a complaint, in Sumter; the case is still open.

Those inspections ended with 5 citation items: 4 serious and 1 other-than-serious.

Penalties were first proposed at $6,875 and still stand at $6,875.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Caterpillar Precision Pin Products Group averages $3,500 (1 cited inspection).

Caterpillar Precision Pin Products Group: OSHA citation items per year, 2000 to 2026
Citation items per year, by inspection date.

South Carolina · latest 90 days of OSHA records

41employers cited

Get notified the morning OSHA posts each new citation in South Carolina: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in South Carolina

Checking a subcontractor, a client or your own company? Watch Caterpillar Precision Pin Products Group and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348695008 OPENED JAN 15, 2026Open

Complaint · Partial · Health · 110 employees at the site · Open

1355 North Wise Drive, Sumter, SC 29153 · Mechanical Power Transmission Equipment Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.36(d)(2) · Exit route design
Serious$3,500$3,500Jun 17, 2026Final

Inspection 317890648 OPENED FEB 26, 2015Closed

Accident · Partial · Safety · 121 employees at the site · Closed Jun 16, 2015

1355 North Wise Drive, Sumter, SC 29153 · Mechanical Power Transmission Equipment Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 315686519 OPENED JUN 2, 2011Closed

Planned · Complete · Safety · 172 employees at the site · Closed Sep 7, 2011

1355 North Wise, Sumter, SC 29150 · Mechanical Power Transmission Equipment Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.106(d)(3)(iia) · Flammable liquids
Serious$1,000$1,000Jul 27, 2011Closed
Citation 1, item 2
29 CFR 1910.304(g)(5) · Grounding and circuit protection
Serious$750$750Jul 27, 2011Closed

Inspection 302433867 OPENED MAY 16, 2000Closed

Accident · Partial · Safety · 125 employees at the site · Closed Jul 18, 2000

1355 North Wise, Sumter, SC 29150 · OSHA's record · Phone and website on Google Maps

Incident on Apr 15, 2000: Employee's finger amputated in inertia welder

Employee #1 was setting up an inertia welder and was loading the linkage pin int o the jaws of the carriage when he inadvertently struck the RAM EXTEND button in stead of the FIXTURE CLAMP button. His right index finger became caught between the linkage pin and the weld plug, and was amputated just above the proximal pha lanx (knuckle).

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$1,625$1,625Jun 9, 2000Closed
Citation 2, item 1
29 CFR 1910.147(c)(6)(ii) · Lockout/tagout
Other-than-serious$0$0Jun 9, 2000Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(d)(3)(iia)

(ii) Fire resistance. Storage cabinets shall be designed and constructed to limit the internal temperature to not more than 325 °F. when subjected to a 10-minute fire test using the standard time-temperature curve as set forth in Standard Methods of Fire Tests of Building Construction and Materials, NFPA 251-1969, which is incorporated by reference as specified in § 1910.6. All joints and seams shall remain tight and the door shall remain securely closed during the fire test. Cabinets shall be labeled in conspicuous lettering, “Flammable—Keep Fire Away.”

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(6)(ii)

(ii) The employer shall certify that the periodic inspections have been performed. The certification shall identify the machine or equipment on which the energy control procedure was being utilized, the date of the inspection, the employees included in the inspection, and the person performing the inspection.

29 CFR 1910.212 · Machine guarding

29 CFR 1910.212(a)(3)(ii)

(ii) The point of operation of machines whose operation exposes an employee to injury, shall be guarded. The guarding device shall be in conformity with any appropriate standards therefor, or, in the absence of applicable specific standards, shall be so designed and constructed as to prevent the operator from having any part of his body in the danger zone during the operating cycle.

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.36 · Exit route design

Other mechanical power transmission equipment manufacturing employers in South Carolina

Alert subscribers get notified of each newly cited employer in South Carolina the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.