Since 1989, OSHA inspectors have visited Central Construction, LLC in Virginia 3 times.

The most recent inspection opened on Feb 7, 2023 after an accident, in Smithfield.

In all, OSHA issued 4 citation items: 4 serious.

The proposed penalties came to $2,670; today they stand at $1,989, 26% less.

Among construction employers, the typical cited inspection since 2015 ends with a $3,079 penalty. Central Construction, LLC averages $1,589 across 1 cited inspection.

Central Construction, LLC: OSHA citation items per year, 1989 to 2023
Citation items per year, by inspection date.

Want to know if OSHA cites Central Construction, LLC again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 346523400 OPENED FEB 7, 2023Closed

Accident · Complete · Safety · 5 employees at the site · Closed Feb 9, 2023

9311 Hardy Circle, Smithfield, VA 23430 · All Other Specialty Trade Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 345670772 OPENED DEC 2, 2021Closed

Complaint · Partial · Safety · 1 employee at the site · Closed May 18, 2022

3208 Silver Sands Circle, Virginia Beach, VA 23450 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.20(b)(2) · Construction safety programs
Serious$2,270$1,589Feb 16, 2022Final

Inspection 105762629 OPENED MAR 13, 1989Closed

Planned · Complete · Safety · 3 employees at the site · Closed May 1, 1989

Rt 257 East, Bridgewater, VA 22812 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.650(e) · Scope, application, and definitions applicable to this subpart
Serious$200$200Apr 7, 1989Closed
Citation 1, item 2a
29 CFR 1926.652(b) · Trench protection
Serious$200$200Apr 7, 1989Closed
Citation 1, item 2b
29 CFR 1926.651(i)(1) · Excavations
Serious$0$0Apr 7, 1989Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.20 · Construction safety programs

29 CFR 1926.20(b)(2)

(2) Such programs shall provide for frequent and regular inspections of the job sites, materials, and equipment to be made by competent persons designated by the employers.

29 CFR 1926.650 · Scope, application, and definitions applicable to this subpart

29 CFR 1926.651 · Excavations

29 CFR 1926.651(i)(1)

(i) Stability of adjacent structures. (1) Where the stability of adjoining buildings, walls, or other structures is endangered by excavation operations, support systems such as shoring, bracing, or underpinning shall be provided to ensure the stability of such structures for the protection of employees.

29 CFR 1926.652 · Trench protection

29 CFR 1926.652(b)

(b) Design of sloping and benching systems. The slopes and configurations of sloping and benching systems shall be selected and constructed by the employer or his designee and shall be in accordance with the requirements of paragraph (b)(1); or, in the alternative, paragraph (b)(2); or, in the alternative, paragraph (b)(3), or, in the alternative, paragraph (b)(4), as follows: