OSHA SearchOSHA records by employer

Central Cove Construction, LLC: OSHA inspections and violations

Caldwell, Idaho · Water and Sewer Line and Related Structures Construction · NAICS 237110

1inspections
4citation items
$7,400current penalties
Mar 21, 2025last inspection

OSHA inspectors have visited Central Cove Construction, LLC in Idaho one time.

It opened on Mar 21, 2025 after a complaint, in Caldwell.

In all, OSHA issued 4 citation items: 4 serious.

The proposed penalties came to $11,349; today they stand at $7,400, 35% less.

The rule cited most here is 1926.651 (excavations), 2 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Central Cove Construction, LLC averages $7,400 across 1 cited inspection.

Central Cove Construction, LLC: OSHA citation items per year, 2025 to 2025
Citation items per year, by inspection date.

Idaho · latest 90 days of OSHA records

62employers cited

Get notified the morning OSHA posts each new citation in Idaho: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Idaho

Checking a subcontractor, a client or your own company? Watch Central Cove Construction, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348129040 OPENED MAR 21, 2025Closed

Complaint · Partial · Safety · 14 employees at the site · Closed Mar 10, 2026

Peregrine Estates Subdivision No.6, Caldwell, ID 83605 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.651(c)(2) · Excavations
Serious$3,972$2,590Jul 29, 2025Final
Citation 1, item 2a
29 CFR 1926.651(k)(2) · Excavations
Serious$3,972$2,590Jul 29, 2025Final
Citation 1, item 2b
29 CFR 1926.652(a)(1) · Trench protection
Serious$0$0Jul 29, 2025Final
Citation 1, item 3
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$3,405$2,220Jul 29, 2025Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.651 · Excavations

29 CFR 1926.651(c)(2)

(2) Means of egress from trench excavations. A stairway, ladder, ramp or other safe means of egress shall be located in trench excavations that are 4 feet (1.22 m) or more in depth so as to require no more than 25 feet (7.62 m) of lateral travel for employees.

29 CFR 1926.651(k)(2)

(2) Where the competent person finds evidence of a situation that could result in a possible cave-in, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions, exposed employees shall be removed from the hazardous area until the necessary precautions have been taken to ensure their safety.

29 CFR 1926.652 · Trench protection

Other water and sewer line and related structures construction employers in Idaho

Alert subscribers get notified of each newly cited employer in Idaho the morning it is posted. See the alert plans.