Central Power Electric Cooperative, Inc.: OSHA inspections and violations

Woodworth, North Dakota · Electric Power Distribution · NAICS 221122

1inspections
3citation items
$9,228current penalties
Jun 27, 2017last inspection

Central Power Electric Cooperative, Inc. has one OSHA inspection on record in North Dakota.

OSHA opened it on Jun 27, 2017 on a referral, in Woodworth.

From that inspection OSHA issued 3 citation items: 2 serious and 1 other-than-serious.

OSHA proposed $18,457 in penalties. After settlements and reviews the total is $9,228, down 50%.

Most often, OSHA cited 1910.269, electric power generation, transmission, and distribution (3 items).

For context, across all utility employers the median penalty per cited inspection since 2015 is $0. Central Power Electric Cooperative, Inc. averages $9,228 over 1 cited inspection in that time.

It reported 1 severe injury to OSHA since 2015.

Central Power Electric Cooperative, Inc.: OSHA citation items per year, 2017 to 2017
Citation items per year, by inspection date.

North Dakota · latest 90 days of OSHA records

26employers cited

Get notified the morning OSHA posts each new citation in North Dakota: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in North Dakota

Checking a subcontractor, a client or your own company? Watch Central Power Electric Cooperative, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342442464 OPENED JUN 27, 2017Closed

Referral · Partial · Safety · 50 employees at the site · Closed Sep 25, 2017

5302 Highway 36 Se, Woodworth, ND 58496 · Electric Power Distribution · OSHA's record · Phone and website on Google Maps

Incident on Jun 27, 2017: Employee receives electric shock when came into contact with

At approximately 8:00 a.m. on June 27, 2017, an employee was working as a lineman on a crew for a power transmission company tasked with removing a part from a distribution bus at a distribution substation. A crew from the distribution service operator was in the process of isolating the distribution lines that were terminated at the substation. The two crews did not properly coordinate their de-energization activities and the transmission crew mistakenly believed the distribution equipment to be properly isolated from the system. The crew did not properly test and ground the equipment prior to starting work. While working on the equipment the employee came into contact with an energized conductor and received electric shock. The employee was hospitalized and treated for electric shock.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.269(m)(3)(ii) · Electric power generation, transmission, and distribution
Serious$8,873$4,436Aug 25, 2017Final
Citation 1, item 2
29 CFR 1910.269(n)(2) · Electric power generation, transmission, and distribution
Serious$8,873$4,436Aug 25, 2017Final
Citation 2, item 1
29 CFR 1910.269(m)(2)(iv) · Electric power generation, transmission, and distribution
Other-than-serious$711$356Aug 25, 2017Final

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.

Jun 27, 2017, Woodworth: Hospitalization · electrocutions, electric shocks · body systems

While removing a glass insulator from a substation, an employee made contact with an energized conductor and suffered an electric shock.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.269 · Electric power generation, transmission, and distribution

29 CFR 1910.269(m)(2)(iv)

(iv) If two or more crews will be working on the same lines or equipment, then:

29 CFR 1910.269(m)(3)(ii)

(ii) The employer shall ensure that all switches, disconnectors, jumpers, taps, and other means through which known sources of electric energy may be supplied to the particular lines and equipment to be deenergized are open. The employer shall render such means inoperable, unless its design does not so permit, and then ensure that such means are tagged to indicate that employees are at work.

29 CFR 1910.269(n)(2)

(2) General. For any employee to work transmission and distribution lines or equipment as deenergized, the employer shall ensure that the lines or equipment are deenergized under the provisions of paragraph (m) of this section and shall ensure proper grounding of the lines or equipment as specified in paragraphs (n)(3) through (n)(8) of this section. However, if the employer can demonstrate that installation of a ground is impracticable or that the conditions resulting from the installation of a ground would present greater hazards to employees than working without grounds, the lines and equipment may be treated as deenergized provided that the employer establishes that all of the following conditions apply:

Other electric power distribution employers in North Dakota

Alert subscribers get notified of each newly cited employer in North Dakota the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.