OSHA SearchOSHA records by employer

Cerro Wire LLC: OSHA inspections and violations

Hartselle, Alabama · Other Communication and Energy Wire Manufacturing · NAICS 335929

6inspections
10citation items
$143,593current penalties
Jan 28, 2026last inspection

Cerro Wire LLC has 6 OSHA inspections on record in Alabama, the first in 2015.

OSHA's last visit started on Jan 28, 2026 on a referral, in Hartselle.

Across those inspections OSHA issued 10 citation items: 7 serious, 1 repeat and 2 other-than-serious.

OSHA proposed $194,107 in penalties. After settlements and reviews the total is $143,593, down 26%.

Most often, OSHA cited 1910.147, lockout/tagout (3 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Cerro Wire LLC averages $28,719 over 5 cited inspections in that time.

Cerro Wire LLC also files yearly injury logs with OSHA, summarized below.

It reported 7 severe injuries to OSHA since 2015.

Cerro Wire LLC: OSHA citation items per year, 2015 to 2026
Citation items per year, by inspection date.

Alabama · latest 90 days of OSHA records

102employers cited

Get notified the morning OSHA posts each new citation in Alabama: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Alabama

Checking a subcontractor, a client or your own company? Watch Cerro Wire LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348714312 OPENED JAN 28, 2026Closed

Referral · Partial · Safety · 240 employees at the site · Closed May 19, 2026

1099 Thompson Road Se, Hartselle, AL 35640 · Other Communication and Energy Wire Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$16,550$16,550Apr 15, 2026Final
Citation 1, item 1b
29 CFR 1910.147(c)(7)(i) · Lockout/tagout
Serious$0$0Apr 15, 2026Final

Inspection 346618440 OPENED APR 6, 2023Closed

Referral · Partial · Safety · 250 employees at the site · Closed Sep 22, 2023

1099 Thompson Rd Se, Hartselle, AL 35640 · Other Communication and Energy Wire Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 345654289 OPENED NOV 22, 2021Closed

Complaint · Partial · Health · 250 employees at the site · Closed May 20, 2022

1099 Thompson Road Southeast, Hartselle, AL 35640 · Other Fabricated Wire Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.1200(f)(6)(i) · Hazard communication
Serious$5,811$3,487Apr 19, 2022Final
Citation 1, item 1b
29 CFR 1910.1200(f)(6)(ii) · Hazard communication
Serious$0$0Apr 19, 2022Final

Inspection 345659601 OPENED NOV 16, 2021Closed

Complaint · Partial · Safety · 278 employees at the site · Closed Jul 27, 2022

1099 Thompson Road Southeast, Hartselle, AL 35640 · Other Communication and Energy Wire Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.178(l)(1)(ii) · Forklifts and other powered industrial trucks
Other-than-serious$14,502$10,151May 16, 2022Final
Citation 1, item 2
29 CFR 1910.178(l)(6) · Forklifts and other powered industrial trucks
Other-than-serious$1,163$815May 16, 2022Final

Inspection 344776018 OPENED JUN 3, 2020Closed

Referral · Partial · Safety · 149 employees at the site · Closed Mar 22, 2022

1099 Thompson Rd Se, Hartselle, AL 35640 · Other Communication and Energy Wire Manufacturing · OSHA's record · Phone and website on Google Maps

Incident on Jun 1, 2020: Employee incurs multiple injuries when caught up in spool

At 3:00 a.m. on June 1, 2020, an employee was running copper wire into a large wooden take up reel. The alarm sounded and then cleared, and then the employee disappeared from the security camera's view. The employee's right foot and body were caught up in the slow rotating copper wire take up spool/reel. The employee was hospitalized to treat a broken left femur and multiple injuries from the waist down.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.145(c)(2) · Specifications for accident prevention signs and tags
Serious$13,494$3,000Nov 25, 2020Final
Citation 2, item 1
29 CFR 1910.212(a)(1) · Machine guarding
Repeat$134,937$105,000Nov 25, 2020Final

Inspection 340472802 OPENED MAR 18, 2015Closed

Referral · Partial · Safety · 123 employees at the site · Closed May 14, 2015

1099 Thompson Road Se, Hartselle, AL 35640 · Other Communication and Energy Wire Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$4,590$2,754Apr 28, 2015Final
Citation 1, item 2
29 CFR 1910.212(a)(1) · Machine guarding
Serious$3,060$1,836Apr 28, 2015Final

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2021, the Hartselle site logged 10 recordable injuries or illnesses among about 278 workers: 3.4 per 100 full-time workers, against a median of 1.5 for its industry. Those cases cost 33 days away from work.

Site and yearWorkersCasesDays-away casesRateIndustry median
Cerro Wire Hartselle
Hartselle · 2021
278 1033.41.5

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 7 reports on file, the 6 most recent shown.

Mar 27, 2025, Hartselle: Amputation · amputations, avulsions, enucleations unspecified · finger or thumb tip(s), nail(s)

On March 27, 2025, an employee was stringing up a wire drawing machine when his right little finger became caught between the wire and the capstan wheel on the machine, resulting in a fingertip amputation.

Mar 24, 2024, Hartselle: Amputation · amputations, avulsions, enucleations unspecified · finger or thumb tip(s), nail(s)

An employee was operating a wire welder when the air actuated welder wire holding arm closed and pinched his right index finger, resulting in a fingertip amputation.

Mar 30, 2023, Hartselle: Hospitalization · internal injuries to organs and blood vessels of the trunk · chest, except internal location of diseases or disorders

An employee was operating a palletizer. While attempting to reposition wire coil from a robotic stacker, the stacker engaged and pinned her against the metal guard opening of the palletizer. She suffered pneumothorax, a pulmonary contusion, and a rib fracture.

Jun 1, 2020, Hartselle: Hospitalization · fractures · thigh(s)

An employee was running copper wire into a large wooden take-up reel when his right foot and body were caught in the rotating reel. He suffered a broken left femur.

May 6, 2018, Hartselle: Hospitalization · third or fourth degree heat (thermal) burns · hand(s), except finger(s)

An employee was running coils through a sealing machine when the coils stopped going all the way into the sealing area. He was attempting to grab a coil that was not properly in the sealing area when the seal bar came down on his left hand, causing third degree burns.

Sep 28, 2015, Hartselle: Hospitalization · fractures · thigh(s)

While making copies, an employee turned, caught the left foot on the copy machine, and fell fracturing the left femur.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(f)(6)(i)

(i) The information specified under paragraphs (f)(1)(i) through (v) of this section for labels on shipped containers; or,

29 CFR 1910.1200(f)(6)(ii)

(ii) Product identifier and words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals, and which, in conjunction with the other information immediately available to employees under the hazard communication program, will provide employees with the specific information regarding the physical and health hazards of the hazardous chemical.

29 CFR 1910.145 · Specifications for accident prevention signs and tags

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(4)(i)

(4) Energy control procedure. (i) Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.212 · Machine guarding

Other other communication and energy wire manufacturing employers in Alabama

Alert subscribers get notified of each newly cited employer in Alabama the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.