OSHA SearchOSHA records by employer

Certainteed Roofing: OSHA inspections and violations

Jonesburg, Missouri · Asphalt Shingle and Coating Materials Manufacturing · NAICS 324122

1inspections
2citation items
$13,653current penalties
Oct 1, 2020last inspection

OSHA inspectors have visited Certainteed Roofing in Missouri one time.

It opened on Oct 1, 2020 on a referral, in Jonesburg.

In all, OSHA issued 2 citation items: 2 serious.

The penalties, $13,653 in total, stand where OSHA first set them.

The rule cited most here is 1910.147 (lockout/tagout), 2 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $4,500 penalty. Certainteed Roofing averages $13,653 across 1 cited inspection.

Certainteed Roofing: OSHA citation items per year, 2020 to 2020
Citation items per year, by inspection date.

Want to know if OSHA cites Certainteed Roofing again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 344960612 OPENED OCT 1, 2020Closed

Referral · Partial · Safety · 126 employees at the site · Closed Apr 26, 2021

100 Certainteed Drive, Jonesburg, MO 63351 · Asphalt Shingle and Coating Materials Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.147(c)(6)(i) · Lockout/tagout
Serious$13,653$13,653Mar 26, 2021Final
Citation 1, item 1b
29 CFR 1910.147(c)(6)(ii) · Lockout/tagout
Serious$0$0Mar 26, 2021Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(6)(i)

(6) Periodic inspection. (i) The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed.

29 CFR 1910.147(c)(6)(ii)

(ii) The employer shall certify that the periodic inspections have been performed. The certification shall identify the machine or equipment on which the energy control procedure was being utilized, the date of the inspection, the employees included in the inspection, and the person performing the inspection.

Other asphalt shingle and coating materials manufacturing employers in Missouri

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.