Air Vent Inc: OSHA inspections and violations

Orrick, Missouri · All Other Petroleum and Coal Products Manufacturing · NAICS 324199

1inspections
2citation items
$11,917current penalties
Jun 23, 2025last inspection

OSHA has inspected Air Vent Inc once in Missouri.

The inspection began on Jun 23, 2025 after a complaint, in Orrick.

That inspection ended with 2 citation items: 2 other-than-serious.

Penalties were first proposed at $17,024 and now stand at $11,917, 30% lower after settlements or reviews.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $4,500, and Air Vent Inc averages $11,917 (1 cited inspection).

It reported 1 severe injury to OSHA since 2015.

Air Vent Inc: OSHA citation items per year, 2025 to 2025
Citation items per year, by inspection date.

Want to know if OSHA cites Air Vent Inc again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 348355108 OPENED JUN 23, 2025Closed

Complaint · Partial · Health · 127 employees at the site · Closed Jan 26, 2026

418 E North Front St, Orrick, MO 64077 · All Other Petroleum and Coal Products Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.178(p)(1) · Forklifts and other powered industrial trucks
Other-than-serious$9,458$6,621Dec 5, 2025Final
Citation 1, item 2
29 CFR 1910.243(b)(2) · Guarding of portable powered tools
Other-than-serious$7,566$5,296Dec 5, 2025Final

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.

Mar 8, 2021, Orrick: Hospitalization · fractures · ankle(s)

An employee was operating a shipping shuttle system. The shuttle malfunctioned, and she tried to unjam it; when it broke free, her ankle was pinched and broken between the shuttle and a rack support.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.178(p)(1)

(p) Operation of the truck. (1) If at any time a powered industrial truck is found to be in need of repair, defective, or in any way unsafe, the truck shall be taken out of service until it has been restored to safe operating condition.

29 CFR 1910.243 · Guarding of portable powered tools

29 CFR 1910.243(b)(2)

(2) Airhose. Hose and hose connections used for conducting compressed air to utilization equipment shall be designed for the pressure and service to which they are subjected.