OSHA SearchOSHA records by employer

Chapin Masonry Construction LLC: OSHA inspections and violations

Durham, North Carolina · Masonry Contractors · NAICS 238140

2inspections
11citation items
$7,675current penalties
Feb 17, 2017last inspection

Since 2009, OSHA inspectors have visited Chapin Masonry Construction LLC in North Carolina 2 times.

The most recent inspection opened on Feb 17, 2017 as a planned inspection, in Raleigh.

In all, OSHA issued 11 citation items: 11 serious.

The proposed penalties came to $10,000; today they stand at $7,675, 23% less.

The rule cited most here is 1926.451 (scaffolds, general requirements), 8 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Chapin Masonry Construction LLC averages $6,975 across 1 cited inspection.

Chapin Masonry Construction LLC: OSHA citation items per year, 2009 to 2017
Citation items per year, by inspection date.

North Carolina · latest 90 days of OSHA records

234employers cited

3 of them in the same industry

Get notified the morning OSHA posts each new citation in North Carolina: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in North Carolina

Checking a subcontractor, a client or your own company? Watch Chapin Masonry Construction LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342125150 OPENED FEB 17, 2017Closed

Planned · Complete · Safety · 8 employees at the site · Closed Oct 18, 2023

3550 Horton Street, Raleigh, NC 27607 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 95.129(01)
Serious$2,100$1,575Apr 6, 2017Final
Citation 1, item 2
29 CFR 1926.451(f)(16) · Scaffolds, general requirements
Serious$2,100$1,575Apr 6, 2017Final
Citation 1, item 3
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$2,100$1,575Apr 6, 2017Final
Citation 1, item 4
29 CFR 1926.451(h)(1) · Scaffolds, general requirements
Serious$2,100$1,575Apr 6, 2017Final
Citation 1, item 5
29 CFR 1926.451(h)(2)(i) · Scaffolds, general requirements
Serious$900$675Apr 6, 2017Final

Inspection 312879851 OPENED MAR 25, 2009Closed

Unprogrammed other · Partial · Safety · 2 employees at the site · Closed Aug 24, 2009

1200 W. Cornwallis Road, Durham, NC 27705 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(b)(1)(i) · Scaffolds, general requirements
Serious$700$700Apr 20, 2009Closed
Citation 1, item 1b
29 CFR 1926.20(b)(2) · Construction safety programs
Serious$0$0Apr 20, 2009Closed
Citation 1, item 1c
29 CFR 1926.451(b)(4) · Scaffolds, general requirements
Serious$0$0Apr 20, 2009Closed
Citation 1, item 1d
29 CFR 1926.451(f)(4) · Scaffolds, general requirements
Serious$0$0Apr 20, 2009Closed
Citation 1, item 1e
29 CFR 1926.451(g)(1)(vi) · Scaffolds, general requirements
Serious$0$0Apr 20, 2009Closed
Citation 1, item 1f
29 CFR 1926.454(a) · Scaffold training
Serious$0$0Apr 20, 2009Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.20 · Construction safety programs

29 CFR 1926.20(b)(2)

(2) Such programs shall provide for frequent and regular inspections of the job sites, materials, and equipment to be made by competent persons designated by the employers.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)(i)

(i) Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) shall be installed so that the space between adjacent units and the space between the platform and the uprights is no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary (for example, to fit around uprights when side brackets are used to extend the width of the platform).

29 CFR 1926.451(b)(4)

(4) Each end of a platform, unless cleated or otherwise restrained by hooks or equivalent means, shall extend over the centerline of its support at least 6 inches (15 cm).

29 CFR 1926.454 · Scaffold training

Other masonry contractors employers in North Carolina

Alert subscribers get notified of each newly cited employer in North Carolina the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.