OSHA SearchOSHA records by employer

Charles Hawkesworth dba CWH Carpentry: OSHA inspections and violations

Topsail Beach, North Carolina · Framing Contractors · NAICS 238130

1inspections
4citation items
$3,600current penalties
Mar 2, 2015last inspection

Charles Hawkesworth dba CWH Carpentry has one OSHA inspection on record in North Carolina.

OSHA opened it on Mar 2, 2015 after a complaint, in Topsail Beach.

From that inspection OSHA issued 4 citation items: 4 serious.

OSHA proposed $3,600 in penalties and the amount has not been reduced.

Most often, OSHA cited 1926.451, scaffolds, general requirements (2 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Charles Hawkesworth dba CWH Carpentry averages $3,600 over 1 cited inspection in that time.

Charles Hawkesworth dba CWH Carpentry: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

North Carolina · latest 90 days of OSHA records

228employers cited

50 of them in the same industry

Get notified the morning OSHA posts each new citation in North Carolina: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in North Carolina

Checking a subcontractor, a client or your own company? Watch Charles Hawkesworth dba CWH Carpentry and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 317947943 OPENED MAR 2, 2015Closed

Complaint · Partial · Safety · 2 employees at the site · Closed Feb 5, 2016

8602 3rd Avenue, Topsail Beach, NC 28460 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(f)(6) · Scaffolds, general requirements
Serious$1,500$1,500Mar 19, 2015Closed
Citation 1, item 1b
29 CFR 1926.20(b)(2) · Construction safety programs
Serious$0$0Mar 19, 2015Closed
Citation 1, item 2a
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$2,100$2,100Mar 19, 2015Closed
Citation 1, item 2b
29 CFR 1926.454(a) · Scaffold training
Serious$0$0Mar 19, 2015Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.20 · Construction safety programs

29 CFR 1926.20(b)(2)

(2) Such programs shall provide for frequent and regular inspections of the job sites, materials, and equipment to be made by competent persons designated by the employers.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(f)(6)

(6) The clearance between scaffolds and power lines shall be as follows: Scaffolds shall not be erected, used, dismantled, altered, or moved such that they or any conductive material handled on them might come closer to exposed and energized power lines than as follows:

29 CFR 1926.451(g)(1)

(g) Fall protection. (1) Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level. Paragraphs (g)(1) (i) through (vii) of this section establish the types of fall protection to be provided to the employees on each type of scaffold. Paragraph (g)(2) of this section addresses fall protection for scaffold erectors and dismantlers.

29 CFR 1926.454 · Scaffold training

Other framing contractors employers in North Carolina

Alert subscribers get notified of each newly cited employer in North Carolina the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.