OSHA SearchOSHA records by employer

Charles Stoll Construction LLC: OSHA inspections and violations

Ladson, South Carolina · Structural Steel and Precast Concrete Contractors · NAICS 238120

4inspections
6citation items
$2,400current penalties
Jul 12, 2018last inspection

Charles Stoll Construction LLC has 4 OSHA inspections on record in South Carolina, the first in 2007.

OSHA's last visit started on Jul 12, 2018 to follow up on an earlier case, in Ladson.

Across those inspections OSHA issued 6 citation items: 6 serious.

OSHA proposed $6,100 in penalties. After settlements and reviews the total is $2,400, down 61%.

Most often, OSHA cited 1926.760, fall protection (2 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Charles Stoll Construction LLC averages $2,100 over 1 cited inspection in that time.

1 inspection on this page followed a fatal incident.

Charles Stoll Construction LLC: OSHA citation items per year, 2007 to 2018
Citation items per year, by inspection date.

South Carolina · latest 90 days of OSHA records

41employers cited

Get notified the morning OSHA posts each new citation in South Carolina: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in South Carolina

Checking a subcontractor, a client or your own company? Watch Charles Stoll Construction LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343360715 OPENED JUL 12, 2018Closed

Follow-up · Partial · Safety · 5 employees at the site · Closed Aug 29, 2018

8501 Palmetto Commerce Parkway, Ladson, SC 29456 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 342707809 OPENED OCT 13, 2017Closed

Fatality or catastrophe · Partial · Safety · 5 employees at the site · Closed Aug 29, 2018

8501 Palmetto Commerce Parkway, Ladson, SC 29456 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

Incident on Oct 12, 2017 (fatal): Employee is killed in 20 foot fall

At 2:30 p.m. on October 12, 2017,Employee #1 was part of a four man crew assigned to install metal guardrails and adjust a steel plate; a project that had been going on for an approximate six weeks. Employee #1 was working on top of the steel plate with a coworker to adjust its position by 3/8 inches. The U-bolts that held the steel plate were previously removed. While the coworker held a sleever tool, Employee #1 used a hammer to hit the top part of the sleever tool, between section 5A and 5B of the steel plate to make the necessary adjustment. During adjustment, the steel plate shifted eastward that created a hole between section 5A and 5B. Employee #1 fell through the hole, an approximate 20 feet, and struck the concrete surface below. Employee #1 suffered blunt force injuries to his chest and abdomen, including multiple rib fractures, and damage to his lungs, liver, and spleen. The employee died as a result of his injuries.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 3a
29 CFR 1926.760(a)(1) · Fall protection
Serious$4,200$2,100Mar 6, 2018Final
Citation 1, item 3b
29 CFR 1926.761(b) · Training
Serious$1,500$0Mar 6, 2018Final

Inspection 313484909 OPENED JUL 14, 2009Closed

Planned · Partial · Safety · 2 employees at the site · Closed Oct 23, 2009

8600 Dorchester Road, North Charleston, SC 29420 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(10) · Fall protection in construction
Serious$100$100Aug 11, 2009Closed
Citation 1, item 2
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$100$100Aug 11, 2009Closed

Inspection 310971304 OPENED JUL 12, 2007Closed

Planned · Partial · Safety · 6 employees at the site · Closed Oct 23, 2007

205 Grandview Dr, Summerville, SC 29483 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$100$50Aug 3, 2007Closed
Citation 1, item 2
29 CFR 1926.760(a)(1) · Fall protection
Serious$100$50Aug 3, 2007Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(g)(1)(vii)

(vii) For all scaffolds not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, each employee shall be protected by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.501(b)(10)

(10) Roofing work on Low-slope roofs. Except as otherwise provided in paragraph (b) of this section, each employee engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet (1.8 m) or more above lower levels shall be protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width (see appendix A to subpart M of this part), the use of a safety monitoring system alone [i.e. without the warning line system] is permitted.

29 CFR 1926.760 · Fall protection

29 CFR 1926.761 · Training

Other structural steel and precast concrete contractors employers in South Carolina

Alert subscribers get notified of each newly cited employer in South Carolina the morning it is posted. See the alert plans.