OSHA SearchOSHA records by employer

Chenango Valley Technologies Inc.: OSHA inspections and violations

Sherburne, New York · All Other Plastics Product Manufacturing · NAICS 326199

4inspections
21citation items
$19,614current penalties
Jul 18, 2025last inspection

Since 2008, OSHA inspectors have visited Chenango Valley Technologies Inc. in New York 4 times.

The most recent inspection opened on Jul 18, 2025 as a planned inspection, in Sherburne.

In all, OSHA issued 21 citation items: 18 serious and 3 other-than-serious.

The proposed penalties came to $36,555; today they stand at $19,614, 46% less.

The rule cited most here is 1910.212 (machine guarding), 3 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $4,500 penalty. Chenango Valley Technologies Inc. averages $7,500 across 1 cited inspection.

Chenango Valley Technologies Inc.: OSHA citation items per year, 2008 to 2025
Citation items per year, by inspection date.

New York · latest 90 days of OSHA records

350employers cited

3 of them in the same industry

Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New York

Checking a subcontractor, a client or your own company? Watch Chenango Valley Technologies Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348383837 OPENED JUL 18, 2025Closed

Planned · No inspection · Safety · 35 employees at the site · Closed Jul 21, 2025

328 Route 12b, Sherburne, NY 13460 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 346493646 OPENED FEB 9, 2023Closed

Planned · Complete · Safety · 60 employees at the site · Closed Jul 12, 2024

328 Route 12b, Sherburne, NY 13460 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.178(l)(1)(i) · Forklifts and other powered industrial trucks
Serious$6,250$3,750Jul 31, 2023Final
Citation 1, item 2
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$6,250$3,750Jul 31, 2023Final
Citation 1, item 3a
29 CFR 1910.335(a)(2)(ii) · Safeguards for personnel protection
Other-than-serious$6,250$0Jul 31, 2023Final
Citation 1, item 3b
29 CFR 1910.335(b)(1) · Safeguards for personnel protection
Other-than-serious$0$0Jul 31, 2023Final

Inspection 338851645 OPENED FEB 13, 2013Closed

Planned · Complete · Safety · 40 employees at the site · Closed Feb 12, 2015

328 Route 12b, Sherburne, NY 13460 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes
Serious$2,975$2,082Mar 11, 2013Final
Citation 1, item 2a
29 CFR 1910.36(h)(2) · Exit route design
Serious$2,975$2,082Mar 11, 2013Final
Citation 1, item 2b
29 CFR 1910.37(a)(3) · Exit routes
Serious$0$0Mar 11, 2013Final
Citation 1, item 2c
29 CFR 1910.37(b)(2) · Exit routes
Serious$0$0Mar 11, 2013Final
Citation 1, item 3
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$1,785$1,250Mar 11, 2013Final
Citation 1, item 4
29 CFR 1910.212(a)(1) · Machine guarding
Serious$1,785$1,250Mar 11, 2013Final
Citation 1, item 5
29 CFR 1910.303(b)(7)(i) · Electrical equipment, general requirements
Serious$1,785$1,250Mar 11, 2013Final

Inspection 312366255 OPENED OCT 16, 2008Closed

Planned · Complete · Safety · 28 employees at the site · Closed Dec 14, 2009

328 Route 12b, Sherburne, NY 13460 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.147(c)(1) · Lockout/tagout
Serious$1,250$810Oct 29, 2008Closed
Citation 1, item 2a
29 CFR 1910.178(l)(1)(i) · Forklifts and other powered industrial trucks
Serious$750$485Oct 29, 2008Closed
Citation 1, item 2b
29 CFR 1910.178(l)(4)(iii) · Forklifts and other powered industrial trucks
Serious$0$0Oct 29, 2008Closed
Citation 1, item 3
29 CFR 1910.212(a)(1) · Machine guarding
Serious$1,250$810Oct 29, 2008Closed
Citation 1, item 4
29 CFR 1910.242(b) · Hand and power tools
Serious$750$485Oct 29, 2008Closed
Citation 1, item 5
29 CFR 1910.304(g)(5) · Grounding and circuit protection
Serious$1,000$640Oct 29, 2008Closed
Citation 1, item 6a
29 CFR 1910.305(b)(1)(i) · Electrical wiring methods
Serious$750$485Oct 29, 2008Closed
Citation 1, item 6b
29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods
Serious$0$0Oct 29, 2008Closed
Citation 1, item 7
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$750$485Oct 29, 2008Closed
Citation 2, item 1
29 CFR 1910.304(f)(1)(iv) · Grounding and circuit protection
Other-than-serious$0$0Oct 29, 2008Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(1)

(c) General—(1) Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, start up or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source, and rendered inoperative.

29 CFR 1910.147(c)(4)(i)

(4) Energy control procedure. (i) Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.212 · Machine guarding

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.242 · Hand and power tools

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.335 · Safeguards for personnel protection

29 CFR 1910.36 · Exit route design

29 CFR 1910.37 · Exit routes

Other all other plastics product manufacturing employers in New York

Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.