OSHA SearchOSHA records by employer

Chester Anderson & Sons Inc: OSHA inspections and violations

Omaha, Nebraska · Masonry Contractors · NAICS 238140

8inspections
11citation items
$4,795current penalties
May 13, 2022last inspection

Chester Anderson & Sons Inc has 8 OSHA inspections on record in Nebraska, the first in 1989.

OSHA's last visit started on May 13, 2022 on a referral, in Gretna.

Across those inspections OSHA issued 11 citation items: 9 serious and 2 other-than-serious.

OSHA proposed $11,271 in penalties. After settlements and reviews the total is $4,795, down 57%.

Most often, OSHA cited 1926.451, scaffolds, general requirements (7 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Chester Anderson & Sons Inc averages $1,000 over 1 cited inspection in that time.

Chester Anderson & Sons Inc: OSHA citation items per year, 1989 to 2022
Citation items per year, by inspection date.

Nebraska · latest 90 days of OSHA records

30employers cited

Get notified the morning OSHA posts each new citation in Nebraska: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Nebraska

Checking a subcontractor, a client or your own company? Watch Chester Anderson & Sons Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345957872 OPENED MAY 13, 2022Closed

Referral · Partial · Safety · 28 employees at the site · Closed Feb 15, 2024

21350 Capehart Road, Gretna, NE 68028 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Incident on May 23, 2022: Employee lacerates head in fall from scaffolding

At 12:00 noon on May 23, 2022, an employee climbed the extension ladder in order to gain access to the hydro mobile scaffolding. While working from the unguarded scaffolding the employee fell approximately ten feet and struck his head on a railing below the scaffolding. The employee suffered no brain injury or concussion; however, he was hospitalized and required seven staples to close the laceration on the back of his head.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Other-than-serious$4,351$1,000Jul 21, 2022Final

Inspection 311462626 OPENED JUN 19, 2008Closed

Unprogrammed related · Partial · Safety · 53 employees at the site · Closed Aug 1, 2008

12520 Westport Parkway, Lavista, NE 68128 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$2,500$1,250Jul 7, 2008Closed
Citation 1, item 2 Other-than-serious$700$350Jul 7, 2008Closed

Inspection 306015090 OPENED JAN 14, 2003Closed

Complaint · Partial · Safety · 35 employees at the site · Closed Jan 15, 2003

8969 Park Drive, Ralston, NE 68127 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 303729016 OPENED OCT 23, 2001Closed

Unprogrammed other · Partial · Safety · 15 employees at the site · Closed Nov 8, 2001

10799 Hwy. 370, Papillion, NE 68046 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$1,125$562Oct 29, 2001Closed

Inspection 300054889 OPENED MAR 15, 1999Closed

Unprogrammed related · Partial · Safety · 35 employees at the site · Closed May 6, 1999

111 S. 18th Street, Omaha, NE 68102 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(e)(8) · Scaffolds, general requirements
Serious$1,125$562Apr 30, 1999Closed

Inspection 300050481 OPENED MAY 6, 1997Closed

Unprogrammed related · Complete · Safety · 8 employees at the site · Closed May 21, 1997

8969 Park Drive, Ralston, NE 68127 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$800$400May 7, 1997Closed

Inspection 101382737 OPENED JUL 13, 1990Closed

Unprogrammed related · Complete · Safety · 12 employees at the site · Closed Sep 27, 1990

North Abbott Drive, Eppley Airport, Omaha, NE 68110 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.59(e)(1) · Hazard communication
Serious$210$210Jul 30, 1990Closed
Citation 1, item 2
29 CFR 1926.59(h) · Hazard communication
Serious$210$210Jul 30, 1990Closed

Inspection 101507838 OPENED MAR 7, 1989Closed

Unprogrammed related · Complete · Safety · 9 employees at the site · Closed May 1, 1989

132nd & Dodge, Omaha, NE 68154 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(d)(6) · Scaffolds, general requirements
Serious$250$250Apr 5, 1989Closed
Citation 1, item 1b
29 CFR 1926.451(d)(7) · Scaffolds, general requirements
Serious$0$0Apr 5, 1989Closed
Citation 1, item 1c
29 CFR 1926.451(a)(13) · Scaffolds, general requirements
Serious$0$0Apr 5, 1989Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(a)(13)

(a) Capacity. (1) Except as provided in paragraphs (a)(2), (a)(3), (a)(4), (a)(5) and (g) of this section, each scaffold and scaffold component shall be capable of supporting, without failure, its own weight and at least 4 times the maximum intended load applied or transmitted to it.

29 CFR 1926.451(b)(1)

(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:

29 CFR 1926.451(d)(6)

(6) When winding drum hoists are used on a suspension scaffold, they shall contain not less than four wraps of the suspension rope at the lowest point of scaffold travel. When other types of hoists are used, the suspension ropes shall be long enough to allow the scaffold to be lowered to the level below without the rope end passing through the hoist, or the rope end shall be configured or provided with means to prevent the end from passing through the hoist.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.59 · Hazard communication

29 CFR 1926.852 · Chutes

Other masonry contractors employers in Nebraska

Alert subscribers get notified of each newly cited employer in Nebraska the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.