OSHA SearchOSHA records by employer

Chucks Grinding Inc: OSHA inspections and violations

Chanhassen, Minnesota · Electroplating, Plating, Polishing, Anodizing, and Coloring · NAICS 332813

9inspections
23citation items
$4,012current penalties
Oct 16, 2025last inspection

Since 1989, OSHA inspectors have visited Chucks Grinding Inc in Minnesota 9 times.

The most recent inspection opened on Oct 16, 2025 as a planned inspection, in Chanhassen.

In all, OSHA issued 23 citation items: 12 serious, 1 repeat and 10 other-than-serious.

The proposed penalties came to $6,000; today they stand at $4,012, 33% less.

The rule cited most here is 1910.147 (lockout/tagout), 5 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Chucks Grinding Inc averages $896 across 3 cited inspections.

Chucks Grinding Inc: OSHA citation items per year, 1989 to 2025
Citation items per year, by inspection date.

Minnesota · latest 90 days of OSHA records

380employers cited

Get notified the morning OSHA posts each new citation in Minnesota: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Minnesota

Checking a subcontractor, a client or your own company? Watch Chucks Grinding Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348560202 OPENED OCT 16, 2025Closed

Planned · Complete · Safety · 8 employees at the site · Closed Dec 3, 2025

8345 Commerce Dr, Chanhassen, MN 55317 · Electroplating, Plating, Polishing, Anodizing, and Coloring · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.28(b)(1)(i) · Fall protection in general industry
Serious$450$270Oct 31, 2025Final
Citation 1, item 2
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$750$450Oct 31, 2025Final
Citation 1, item 3
29 CFR 1910.147(c)(7)(i) · Lockout/tagout
Serious$750$450Oct 31, 2025Final
Citation 1, item 4
29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements
Serious$1,050$630Oct 31, 2025Final
Citation 1, item 5 Other-than-serious$300$180Oct 31, 2025Final

Inspection 344383740 OPENED OCT 15, 2019Closed

Planned · Complete · Safety · 15 employees at the site · Closed Dec 6, 2019

8345 Commerce Dr, Chanhassen, MN 55317 · Electroplating, Plating, Polishing, Anodizing, and Coloring · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.219(f)(3) · Belts, pulleys and power-transmission parts
Serious$375$262Oct 24, 2019Final
Citation 2, item 1 Other-than-serious$100$70Oct 24, 2019Final

Inspection 341828556 OPENED OCT 10, 2016Closed

Planned · Complete · Safety · 16 employees at the site · Closed Mar 28, 2017

8345 Commerce Dr, Chanhassen, MN 55317 · Electroplating, Plating, Polishing, Anodizing, and Coloring · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 2
29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods
Serious$375$375Jan 31, 2017Final

Inspection 317150951 OPENED MAY 29, 2013Closed

Planned · Complete · Health · 15 employees at the site · Closed Jun 24, 2013

8345 Commerce Dr, Chanhassen, MN 55317 · Electroplating, Plating, Polishing, Anodizing, and Coloring · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$300$210Jun 4, 2013Closed

Inspection 314718768 OPENED JUL 29, 2010Closed

Planned · Complete · Safety · 9 employees at the site · Closed Sep 24, 2010

8345 Commerce Dr, Chanhassen, MN 55317 · Electroplating, Plating, Polishing, Anodizing, and Coloring · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$225$158Aug 9, 2010Closed

Inspection 310898846 OPENED FEB 16, 2007Closed

Planned · Complete · Safety · 20 employees at the site · Closed Apr 12, 2007

8345 Commerce Drive, Chanhassen, MN 55317 · All Other Miscellaneous Fabricated Metal Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$225$158Mar 19, 2007Closed
Citation 1, item 2
29 CFR 1910.147(c)(6)(i) · Lockout/tagout
Serious$225$157Mar 19, 2007Closed
Citation 1, item 3
29 CFR 1910.151(c) · First aid and eyewash
Serious$300$210Mar 19, 2007Closed
Citation 1, item 4
29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements
Serious$375$262Mar 19, 2007Closed

Inspection 301856829 OPENED JAN 16, 1998Closed

Complaint · Partial · Health · 16 employees at the site · Closed Feb 17, 1998

8345 Commerce Drive, Chanhassen, MN 55317 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.151(c) · First aid and eyewash
Other-than-serious$100$70Jan 27, 1998Closed

Inspection 111700696 OPENED OCT 4, 1990Closed

Complaint · Partial · Safety · 20 employees at the site · Closed Mar 5, 1993

11300 K-tel Drive, Minnetonka, MN 55343 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Repeat$100$100Oct 19, 1990Closed
Citation 2, item 1
29 CFR 1910.305(g)(1)(iii) · Electrical wiring methods
Other-than-serious$0$0Oct 19, 1990Closed
Citation 2, item 2
29 CFR 1910.305(b)(2) · Electrical wiring methods
Other-than-serious$0$0Oct 19, 1990Closed
Citation 2, item 3
29 CFR 1910.147(c)(1) · Lockout/tagout
Other-than-serious$0$0Oct 19, 1990Closed
Citation 2, item 4
29 CFR 1910.303(b)(1) · Electrical equipment, general requirements
Other-than-serious$0$0Oct 19, 1990Closed
Citation 2, item 5
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Other-than-serious$0$0Oct 19, 1990Closed
1 older inspection

Inspection 107792665 OPENED MAR 14, 1989Closed

Planned · Complete · Safety · 24 employees at the site · Closed Apr 9, 1989

11300 K-tel Drive, Minnetonka, MN 55343 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Other-than-serious$0$0Apr 6, 1989Closed
Citation 1, item 2
29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements
Other-than-serious$0$0Apr 6, 1989Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(1)

(c) General—(1) Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, start up or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source, and rendered inoperative.

29 CFR 1910.147(c)(4)(i)

(4) Energy control procedure. (i) Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.

29 CFR 1910.147(c)(6)(i)

(6) Periodic inspection. (i) The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed.

29 CFR 1910.151 · First aid and eyewash

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.28 · Fall protection in general industry

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

29 CFR 5205.116

29 CFR 5205.890

29 CFR 5210.630

Other electroplating, plating, polishing, anodizing, and coloring employers in Minnesota

Alert subscribers get notified of each newly cited employer in Minnesota the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.