OSHA SearchOSHA records by employer

Cityview Construction Corp.: OSHA inspections and violations

Belleville, New Jersey · New Multifamily Housing Construction (except For-Sale Builders) · NAICS 236116

3inspections
25citation items
$157,016current penalties
Sep 1, 2017last inspection

Since 2016, OSHA inspectors have visited Cityview Construction Corp. in New Jersey 3 times.

The most recent inspection opened on Sep 1, 2017 to follow up on an earlier case, in Belleville.

In all, OSHA issued 25 citation items: 22 serious, 1 repeat and 2 other-than-serious.

The proposed penalties came to $211,888; today they stand at $157,016, 26% less.

The rule cited most here is 1910.134 (respiratory protection), 6 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Cityview Construction Corp. averages $78,508 across 2 cited inspections.

Cityview Construction Corp.: OSHA citation items per year, 2016 to 2017
Citation items per year, by inspection date.

New Jersey · latest 90 days of OSHA records

269employers cited

Get notified the morning OSHA posts each new citation in New Jersey: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New Jersey

Checking a subcontractor, a client or your own company? Watch Cityview Construction Corp. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342622958 OPENED SEP 1, 2017Closed

Follow-up · Partial · Health · 65 employees at the site · Closed Nov 3, 2017

520 Belleville Ave., Belleville, NJ 07109 · New Multifamily Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 341566743 OPENED JUN 21, 2016Closed

Referral · Partial · Health · 400 employees at the site · Closed Mar 12, 2018

520 Belleville Ave., Belleville, NJ 07109 · New Multifamily Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.134(c) · Respiratory protection
Serious$8,908$1,500Sep 14, 2016Final
Citation 1, item 1b
29 CFR 1910.134(d)(1)(iii) · Respiratory protection
Serious$0$0Sep 14, 2016Final
Citation 1, item 1c
29 CFR 1910.134(e)(1) · Respiratory protection
Serious$0$0Sep 14, 2016Final
Citation 1, item 1d
29 CFR 1910.134(f)(2) · Respiratory protection
Serious$0$0Sep 14, 2016Final
Citation 1, item 1e
29 CFR 1910.134(g)(1)(i)(a) · Respiratory protection
Serious$0$0Sep 14, 2016Final
Citation 1, item 1f
29 CFR 1910.134(k)(1)(i) · Respiratory protection
Serious$0$0Sep 14, 2016Final
Citation 1, item 2a
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$8,908$1,500Sep 14, 2016Final
Citation 1, item 2b
29 CFR 1910.1200(h)(1) · Hazard communication
Serious$0$0Sep 14, 2016Final
Citation 2, item 1
29 CFR 1903.19(c)(1) · Proving cited hazards were fixed
Other-than-serious$1,016$1,016Aug 17, 2017Final

Inspection 341303550 OPENED FEB 22, 2016Closed

Complaint · Partial · Safety · 66 employees at the site · Closed Jan 8, 2020

520 Belleville Ave, Belleville, NJ 07109 · New Multifamily Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.303(b)(1) · Abrasive wheels and tools
Serious$6,236$12,471Aug 19, 2016Final
Citation 1, item 2a
29 CFR 1926.404(f)(6) · Ground-fault protection on job sites
Serious$6,236$12,471Aug 19, 2016Final
Citation 1, item 2b
29 CFR 1926.404(b)(1)(i) · Ground-fault protection on job sites
Serious$6,236$0Aug 19, 2016Final
Citation 1, item 2c
29 CFR 1926.416(e)(1) · Electrical safety in construction
Serious$6,236$0Aug 19, 2016Final
Citation 1, item 3
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$8,730$12,471Aug 19, 2016Final
Citation 1, item 4
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Serious$8,730$12,471Aug 19, 2016Final
Citation 1, item 5
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$12,471$12,471Aug 19, 2016Final
Citation 1, item 6a
29 CFR 1926.501(b)(4)(i) · Fall protection in construction
Serious$8,730$12,471Aug 19, 2016Final
Citation 1, item 6b
29 CFR 1926.501(b)(14) · Fall protection in construction
Serious$8,730$0Aug 19, 2016Final
Citation 1, item 6c
29 CFR 1926.501(b)(15) · Fall protection in construction
Serious$8,730$0Aug 19, 2016Final
Citation 1, item 7a
29 CFR 1926.502(i)(3) · Fall protection systems
Serious$6,236$12,471Aug 19, 2016Final
Citation 1, item 7b
29 CFR 1926.502(i)(4) · Fall protection systems
Serious$3,741$0Aug 19, 2016Final
Citation 1, item 8
29 CFR 1926.503(a)(1) · Fall protection training in construction
Serious$6,236$12,471Aug 19, 2016Final
Citation 1, item 9
29 CFR 1926.1051(a) · Stairways and Ladders: general requirements
Serious$7,482$12,471Aug 19, 2016Final
Citation 2, item 1
29 CFR 1926.501(b)(4)(i) · Fall protection in construction
Repeat$87,296$40,761Aug 19, 2016Final
Citation 3, item 1
29 CFR 1904.40(a) · Giving injury records to OSHA
Other-than-serious$1,000$0Aug 19, 2016Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1903.19 · Proving cited hazards were fixed

29 CFR 1903.19(c)(1)

(c) Abatement certification. (1) Within 10 calendar days after the abatement date, the employer must certify to OSHA (the Agency) that each cited violation has been abated, except as provided in paragraph (c)(2) of this section.

29 CFR 1904.40 · Giving injury records to OSHA

29 CFR 1904.40(a)

(a) Basic requirement. When an authorized government representative asks for the records you keep under part 1904, you must provide copies of the records within four (4) business hours.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1910.134 · Respiratory protection

29 CFR 1926.1051 · Stairways and Ladders: general requirements

29 CFR 1926.303 · Abrasive wheels and tools

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.416 · Electrical safety in construction

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.502 · Fall protection systems

29 CFR 1926.503 · Fall protection training in construction

Other new multifamily housing construction (except for-sale builders) employers in New Jersey

Alert subscribers get notified of each newly cited employer in New Jersey the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.