OSHA SearchOSHA records by employer

CK King Builders, LLC: OSHA inspections and violations

Wilmington, Delaware · Roofing Contractors · NAICS 238160

1inspections
3citation items
$5,807current penalties
Oct 21, 2024last inspection

OSHA has inspected CK King Builders, LLC once in Delaware.

The inspection began on Oct 21, 2024 after a complaint, in Wilmington.

That inspection ended with 3 citation items: 3 serious.

Penalties were first proposed at $8,296 and now stand at $5,807, 30% lower after settlements or reviews.

Forklifts and other powered industrial trucks comes up most often in these citations: 3 items under 1910.178.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and CK King Builders, LLC averages $5,807 (1 cited inspection).

CK King Builders, LLC: OSHA citation items per year, 2024 to 2024
Citation items per year, by inspection date.

Delaware · latest 90 days of OSHA records

31employers cited

7 of them in the same industry

Get notified the morning OSHA posts each new citation in Delaware: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Delaware

Checking a subcontractor, a client or your own company? Watch CK King Builders, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347827933 OPENED OCT 21, 2024Closed

Complaint · Partial · Safety · 2 employees at the site · Closed Oct 20, 2026

9th & Bennett, Wilmington, DE 19801 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.178(a)(4) · Forklifts and other powered industrial trucks
Serious$5,531$3,872Dec 18, 2024Final
Citation 1, item 1b
29 CFR 1910.178(a)(5) · Forklifts and other powered industrial trucks
Serious$0$0Dec 18, 2024Final
Citation 1, item 2
29 CFR 1910.178(l)(4)(iii) · Forklifts and other powered industrial trucks
Serious$2,765$1,936Dec 18, 2024Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.178(a)(4)

(4) Modifications and additions which affect capacity and safe operation shall not be performed by the customer or user without manufacturers prior written approval. Capacity, operation, and maintenance instruction plates, tags, or decals shall be changed accordingly.

29 CFR 1910.178(a)(5)

(5) If the truck is equipped with front-end attachments other than factory installed attachments, the user shall request that the truck be marked to identify the attachments and show the approximate weight of the truck and attachment combination at maximum elevation with load laterally centered.

29 CFR 1910.178(l)(4)(iii)

(iii) An evaluation of each powered industrial truck operator's performance shall be conducted at least once every three years.

Other roofing contractors employers in Delaware

Alert subscribers get notified of each newly cited employer in Delaware the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.