OSHA SearchOSHA records by employer

Classic Fire Protection, Inc.: OSHA inspections and violations

Nicholson, Pennsylvania · Plumbing, Heating, and Air-Conditioning Contractors · NAICS 238220

1inspections
2citation items
$1,106current penalties
Sep 14, 2020last inspection

Classic Fire Protection, Inc. has one OSHA inspection on record in Pennsylvania.

OSHA opened it on Sep 14, 2020 as a planned inspection, in Nicholson.

From that inspection OSHA issued 2 citation items: 2 serious.

OSHA proposed $1,475 in penalties. After settlements and reviews the total is $1,106, down 25%.

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Classic Fire Protection, Inc. averages $1,106 over 1 cited inspection in that time.

Classic Fire Protection, Inc.: OSHA citation items per year, 2020 to 2020
Citation items per year, by inspection date.

Pennsylvania · latest 90 days of OSHA records

277employers cited

7 of them in the same industry

Get notified the morning OSHA posts each new citation in Pennsylvania: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Pennsylvania

Checking a subcontractor, a client or your own company? Watch Classic Fire Protection, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344925037 OPENED SEP 14, 2020Closed

Planned · Complete · Safety · 2 employees at the site · Closed Feb 5, 2021

21 Lackawanna Trail, Nicholson, PA 18441 · Plumbing, Heating, and Air-Conditioning Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.404(b)(1)(ii) · Ground-fault protection on job sites
Serious$1,475$1,106Jan 5, 2021Final
Citation 1, item 1b
29 CFR 1926.405(b)(2) · Job-site wiring
Serious$0$0Jan 5, 2021Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.404(b)(1)(ii)

(ii) Ground-fault circuit interrupters. All 120-volt, single-phase, 15- and 20-ampere receptacle outlets on construction sites, which are not a part of the permanent wiring of the building or structure and which are in use by employees, shall have approved ground-fault circuit interrupters for personnel protection. Receptacles on a two-wire, single-phase portable or vehicle-mounted generator rated not more than 5kW, where the circuit conductors of the generator are insulated from the generator frame and all other grounded surfaces, need not be protected with ground-fault circuit interrupters.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.405(b)(2)

(2) Covers and canopies. All pull boxes, junction boxes, and fittings shall be provided with covers. If metal covers are used, they shall be grounded. In energized installations each outlet box shall have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear.

Other plumbing, heating, and air-conditioning contractors employers in Pennsylvania

Alert subscribers get notified of each newly cited employer in Pennsylvania the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.