Inspection 349284851 OPENED NOV 9, 2026Open
1140 Washington Road, Bridgeville, PA 15017 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection so far.
Pittsburgh, Pennsylvania · Electrical Contractors and Other Wiring Installation Contractors · NAICS 238210
OSHA has inspected Omni Electric Inc. 5 times in Pennsylvania since 1993.
The latest one began on Nov 9, 2026, in Bridgeville; the case is still open.
Those inspections ended with 8 citation items: 3 serious and 5 other-than-serious.
Penalties were first proposed at $2,250 and now stand at $1,150, 49% lower after settlements or reviews.
Job-site wiring comes up most often in these citations: 3 items under 1926.405.
How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Omni Electric Inc. averages $0 (2 cited inspections).
Pennsylvania · latest 90 days of OSHA records
277employers cited
4 of them in the same industry
Get notified the morning OSHA posts each new citation in Pennsylvania: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Pennsylvania
Checking a subcontractor, a client or your own company? Watch Omni Electric Inc. and get notified the morning OSHA posts a new citation for it.
Watch this company1140 Washington Road, Bridgeville, PA 15017 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection so far.
7601 Mcknight Road, Pittsburgh, PA 15237 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.501(b)(4)(ii) · Fall protection in construction |
Other-than-serious | $0 | $0 | Dec 6, 2019 | Final |
8950 Coventry Avenue, Pittsburgh, PA 15237 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.150(c)(1)(i) · Fire protection |
Other-than-serious | $0 | $0 | Jul 27, 2015 | Final |
| Citation 1, item 2 29 CFR 1926.405(b)(2) · Job-site wiring |
Other-than-serious | $0 | $0 | Jul 27, 2015 | Final |
123 East Pike Street, Canonsburg, PA 15317 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Pellis Road, Greensburg, PA 15338 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1926.25(b) · Housekeeping |
Serious | $450 | $150 | Jan 27, 1994 | Closed |
| Citation 1, item 2 29 CFR 1926.405(a)(2)(iie) · Job-site wiring |
Serious | $750 | $500 | Jan 27, 1994 | Closed |
| Citation 1, item 3 29 CFR 1926.405(a)(2)(iif) · Job-site wiring |
Serious | $750 | $500 | Jan 27, 1994 | Closed |
| Citation 2, item 1 29 CFR 1903.2(a)(1) · Posting of notice; availability of the Act, regulations and applicable standards |
Other-than-serious | $300 | $0 | Jan 27, 1994 | Closed |
| Citation 2, item 3 29 CFR 1926.150(c)(1)(i) · Fire protection |
Other-than-serious | $0 | $0 | Jan 27, 1994 | Closed |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1903.2(a)(1)
(a)(1) Each employer shall post and keep posted a notice or notices, to be furnished by the Occupational Safety and Health Administration, U.S. Department of Labor, informing employees of the protections and obligations provided for in the Act, and that for assistance and information, including copies of the Act and of specific safety and health standards, employees should contact the employer or the nearest office of the Department of Labor. Such notice or notices shall be posted by the employer in each establishment in a conspicuous place or places where notices to employees are customarily posted. Each employer shall take steps to insure that such notices are not altered, defaced, or covered by other material.
29 CFR 1926.150(c)(1)(i)
(c) Portable firefighting equipment—(1) Fire extinguishers and small hose lines. (i) A fire extinguisher, rated not less than 2A, shall be provided for each 3,000 square feet of the protected building area, or major fraction thereof. Travel distance from any point of the protected area to the nearest fire extinguisher shall not exceed 100 feet.
29 CFR 1926.25(b)
(b) Combustible scrap and debris shall be removed at regular intervals during the course of construction. Safe means shall be provided to facilitate such removal.
Alert subscribers get notified of each newly cited employer in Pennsylvania the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.