OSHA SearchOSHA records by employer

CMZ Framing: OSHA inspections and violations

West Valley City, Utah · Framing Contractors · NAICS 238130

1inspections
5citation items
$1,500current penalties
Jul 28, 2021last inspection

OSHA inspectors have visited CMZ Framing in Utah one time.

It opened on Jul 28, 2021 on a referral, in West Valley City.

In all, OSHA issued 5 citation items: 4 serious and 1 other-than-serious.

The proposed penalties came to $3,000; today they stand at $1,500, 50% less.

The rule cited most here is 1926.451 (scaffolds, general requirements), 2 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,079 penalty. CMZ Framing averages $1,500 across 1 cited inspection.

CMZ Framing: OSHA citation items per year, 2021 to 2021
Citation items per year, by inspection date.

Want to know if OSHA cites CMZ Framing again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 345452726 OPENED JUL 28, 2021Closed

Referral · Partial · Safety · 5 employees at the site · Closed Nov 1, 2021

3742 S 5725 W, West Valley City, UT 84081 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(a)(6) · Scaffolds, general requirements
Serious$1,500$750Sep 27, 2021Final
Citation 1, item 1b
29 CFR 1926.454(b) · Scaffold training
Serious$0$0Sep 27, 2021Final
Citation 1, item 1c
29 CFR 1926.602(c)(1)(ii) · Earthmovers and forklifts in construction
Serious$0$0Sep 27, 2021Final
Citation 1, item 2
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$1,500$750Sep 27, 2021Final
Citation 2, item 1
29 CFR 1910.178(l)(6) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Sep 27, 2021Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.178(l)(6)

(6) Certification. The employer shall certify that each operator has been trained and evaluated as required by this paragraph (l). The certification shall include the name of the operator, the date of the training, the date of the evaluation, and the identity of the person(s) performing the training or evaluation.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(a)(6)

(6) Scaffolds shall be designed by a qualified person and shall be constructed and loaded in accordance with that design. Non-mandatory appendix A to this subpart contains examples of criteria that will enable an employer to comply with paragraph (a) of this section.

29 CFR 1926.451(f)(3)

(3) Scaffolds and scaffold components shall be inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity.

29 CFR 1926.454 · Scaffold training

29 CFR 1926.602 · Earthmovers and forklifts in construction

Other framing contractors employers in Utah

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.